26 Installation
(for qualified installers only)
© Travis Industries
8/24/2017 - 1450
42 Apex CF
Insulated Chimney Requirements (7” Inner Diameter)
Security ASHT+ (S2100+) Part Numbers (available through Travis Ind.)
Security ASHT+ (S2100+) Chimney Components
7” Internal diameter, 9” outside diameter
Part #
VENT, 7” ANCHOR PLATE
(REQUIRED) – Includes Instruction Sheet
98900290
VENT, 7" 48" CHIMNEY
98900280
VENT, 7" 36" CHIMNEY
98900281
VENT, 7" 24" CHIMNEY
98900282
VENT, 7" 18" CHIMNEY
98900283
VENT, 7" 12" CHIMNEY
98900284
VENT, 7" 30° OFFSETS (INCLUDES 2 ELBOWS W SUPPORT)
98900285
VENT, 7" RAD FIRESTOP
98900286
VENT, 7" ATTIC SHIELD
98900287
VENT, 7" FLASH 0-6/12
98900288
VENT, 7" FLASH 7-12/12
98900289
VENT, 7" WALL STRAP
98900292
VENT, 7" EXT ROOF BRKT
98900293
VENT, 7" STORM COLLAR
98900294
VENT, 7" CHIMNEY CAP
98900295
Security ASHT+ - Clearances to Combustibles
Maintain a 2" clearance from the chimney to combustibles.
Recommended Space Between Frames = 13-1/4”
Space
between
frames
Firestop
Security ASHT+– Anchor Plate Installation
The chimney requires an anchor plate. Attach
the plate to the top of the fireplace with the four
included sheet-metal screws (see illustration to
the right).
Tabs on anchor plate will need to be crimped
before installation.
Seal the fireplace connection with high-
temperature silicone.
Seal the flue liner with furnace cement.
High-Temperature
Silicone
Use high-temperature silicone to
seal the anchor plate.
Furnace Cement
Security ASHT+– Offset Chart