24 Installation
(for qualified installers only)
© Travis Industries
8/24/2017 - 1450
42 Apex CF
Air Cooled Chimney – Installation and System Height
Minimum 15' system
height (measured
from the base of the
fireplace)
Maximum 35' system
height (measured
from the base of the
fireplace)
MINIMUM HEIGHT
WITH OFFSETS
One Pair (2) Offsets
Mininum system
height is 17’.
Two Pairs (4) Offsets
Minimum chimney
height is 19’.
NOTE:
In problematic
locations (areas with
high wind or at altitude,
etc.) additional chimney
height above the
specified minimum may
be necessary to reduce
wind-induced down
drafts, back puffing, or
smoke spillage. By
adding additional
chimney, the fireplace
will have increased draft
and encounter less
negative operating
characteristics.
Chimney must be totally
enclosed when passing
through living space with a
minimum 2" (51mm)
clearance to combustibles.
System Height
35' Max. (10.5M)
15' Min. (4.5M)
2" (51mm) Min.
Air Space to
Combustibles
Cap (see "Chimney
Termination Requirements")
Storm Collar
Flashing
Firestop Required Between
Floor Levels (or fireplace
enclosure)
Attic Firestop (with insulation shield)
Maximum 8' Chimney Section
(4' if two pairs of 30° elbows
used)
Maximum
30°
Do not seal or caulk the area
between the chimney and flashing.
2" (51mm) Min.
Air Space to
Combustibles