9
ZERO CLEARANCE INSTALLATION - SPECIFICATIONS (Cont.)
Chase Framing
The next consideration is the chase framing that surrounds the fireplace. The opening must
be framed to the dimensions shown in the illustration below for the size of the fireplace being
installed. Fireplace Xtrordinair suggests that the framing that is above the fireplace be
installed after the fireplace is installed to make the chimney installation easier. Consider
installing the fireplace in the desired location and then constructing the framing around it to
the proper clearances.
26"
45 1/2"
43"
When determining the depth, make sure to adhere to all of the minimum clearances outlined
in this manual. Make sure to carefully check all of the specifications and make a detailed
sketch outlining all the distances for this construction before beginning. If the chase does not
work out to be the desired depth based on the facing material, additional framing may be
added to the front of the existing framing to shim the facing to the needed location.
The chase may safely make direct contact with the spacers on the top, rear, and sides of the
fireplace.
WARNING: DO NOT PACK THE REQUIRED AIR SPACES AROUND THE
FIREPLACE OR BETWEEN THE SPACERS WITH INSULATION OR OTHER
MATERIALS.