29
DETAILING THE FIREPLACE (Continued)
5.
Put all the screws in a few turns before tightening them up. If a screw starts hard, back it
out until a click can be heard, then start it in again. Tighten all the screws.
6.
The next step is to attach the switch plate and rheostat. Connect the two quick-connects
coming from the rheostat to the quick-connects coming from the fireplace (see the
illustration below). The orientation of these two wires does not matter. Push all of the
excess wire into the space next to the door switch. Attach the switch plate to the
faceplate with the two screws included with the switch plate. When tightening the screws,
be careful not to pinch the wires.
NOTE
:
If you wish to test the fan prior to actually starting the stove, the two wires
leading to the thermodisk will need to be jumped together. Once those two
wires are connected and the door is closed, the fan will come on.
Firebox
Warning Label
Front View of Fireplace
with Faceplate Removed
Black
Black
White
White
Black
White
White
Black
Exposed
Ground Wires
This connector is
for the optional
temperature monitor
White
Black
Connect these wires
during installation
(orientation does not
matter)
Blower Conduit
Power
Conduit
The switch plate
covers this area here
Rheostat (attached
to the swtich plate)
Door Switch
Thermodisk