background image

 

14

 

FX.FP.

Issue 08 09/12

 

8.1 
 
FX4/FP4 Stove 
Dimensions 

 

FX Door Style Shown 

Содержание FP 5 Wide

Страница 1: ...order to ensure compliance at all times FX FP 4 5 5 Wide 8 FREESTANDING STOVE RANGE 4 5 5 8 kW Nominal Outputs With Patented TTi Air System Installation and Operating Instructions Please hand these instructions to the stove user when the installation is complete Leave the stove ready for operation and instruct the user in the correct use of the appliance and operation of controls Important These p...

Страница 2: ...ation 3 4 Installation Information 4 4 1 Chimney 4 4 2 Ventilation 5 4 3 Flue Draught 5 4 4 Connection to Chimney 5 4 5 Material Clearances 6 4 6 Hearths 6 4 7 Commissioning Handover 6 5 Technical Data 7 6 Operating Instructions 8 6 1 DEFRA Clean Air Act 8 6 2 Air controls 8 6 3 Cleaning 9 6 4 Fuels 10 6 5 Important Notes for Wood Burning 10 6 6 Notes on Smokeless fuel Ancit burning 11 6 7 Lightin...

Страница 3: ...n the door and remove all the contents THE DOOR HANDLE MAY BE PACKED ON TOP OF THE BAFFLE PLATE REACH THROUGH THE TOP SPIGOT OPENING TO FIND IT See List of Components section and check contents carefully 2 1 To remove the baffle plate first remove the two stainless steel side firebox liner clips by lifting them above the fuel retainer Remove the two firebox side liners Now remove the firebox rear ...

Страница 4: ...downloaded for no cost at http www planningportal gov uk england professionals en 4000000000503 html Also of importance are Approved documents L1 A and B conservation of fuel and power The Domestic Heating Compliance Guide will also be found useful In addition to these instructions the requirements of BS 8303 and BS EN 15287 must be fulfilled The installation is a notifiable building works as defi...

Страница 5: ...ne Stoves are very heavily built so always ask for assistance when lifting and siting the stoves 3 1 9 Fire Cement Some types of fire cement are caustic and should not be allowed to come into contact with the skin In case of skin contact wash immediately with plenty of water 3 1 10 Asbestos This stove contains no asbestos If there is a possibility of disturbing any asbestos in the course of instal...

Страница 6: ...hould be checked under fire at high output and if it exceeds the recommended maximum a draught stabiliser must be fitted so that the rate of burning can be controlled to prevent over firing 4 4 Connection to the Chimney This appliance is not suitable for use in a shared flue When using a liner a 5 flexible flue liner is permitted be used on the FX FP 5 5W models ONLY providing that they only burn ...

Страница 7: ...p of at least 50mm must be left around the sides and top and at least 50mm at the back of the stove to obtain reasonable heat output and for access to the stove for removal and maintenance A clearance of 150mm will give a better heat output All non combustible walls closer than 400mm to the stove should be at least 75mm thick For practical reasons the back wall of the fireplace recess and the hear...

Страница 8: ...ns and operating tools including gloves for the stove are left with the customer You must be sure to advise the customer on the correct use of the appliance with the fuels likely to be used on the stove and warn them to use only the recommended fuels for the stove Advise the user on what to do should smoke or fumes be emitted into the room from the stove see Safety Notes section The user should be...

Страница 9: ...ted from the controls which generally apply in the smoke control area The Secretary of State for Environment Food and Rural Affairs has powers under the Act to authorise smokeless fuels or exempt appliances for use in smoke control areas in England In Scotland and Wales this power rests with Ministers in the devolved administrations for those countries Separate legislation the Clean Air Northern I...

Страница 10: ...e pointed part of the multi tool into the knob and lifting up and down or pulling and pushing the knob depending on the model The grate is a strong set of cast iron bars with suitable air slots that assist the burning of most fuels When burning coal type fuels it is important to use the shaker grate and a poker where required to de ash regularly to ensure that the primary airflow is not impeded as...

Страница 11: ... then control the burn rate of the stove Always make sure that flames are visible above the wood after re fuelling for cleanest burning After re fuelling open the air wash full for 3 to 5 minutes or until the logs are fully blackened to achieve full flames above the fuel Wood burns best on a bed of ash and it is therefore only necessary to remove surplus ash from the stove occasionally Burn only d...

Страница 12: ...firebox with plenty of starting fuel i e paper dry kindling sticks and or firelighters If using Ancit place a layer of ancit into the firebox as well Light the fire at the base leaving the secondary air control fully open Leave the door slightly ajar for 10 minutes to enhance initial starting and reduce smoke emission DO NOT leave the stove unattended if the door is left ajar Allow the fuel to rea...

Страница 13: ...en first and then open the secondary air controls Warning The stove will remain very hot for a considerable time after the fire has died down or been extinguished Notes Warning Petroleum coke fuels or household waste must not be burnt on this appliance Should any difficulties arise over fuel quality or suitability consult your local approved fuel merchant 6 10 Shut down for prolonged periods If th...

Страница 14: ...se of fuel from the appliance 3 Check for flue chimney blockage and clean if required 4 Do not attempt to re light the fire until the cause has been identified and corrected If necessary seek professional advice from chimney or stove specialists Important Do not fit an extractor fan in the same room as this appliance IN THE EVENT OF A CHIMNEY FIRE Raise the alarm to let others in the house know Ca...

Страница 15: ...14 FX FP Issue 08 09 12 8 1 FX4 FP4 Stove Dimensions FX Door Style Shown ...

Страница 16: ...15 FX FP Issue 08 09 12 8 2 FX5 FP5 Stove Dimensions FP Door Style Shown ...

Страница 17: ...16 FX FP Issue 08 09 12 8 3 FX5 FP5W Stove Dimensions FX Door Style Shown ...

Страница 18: ...17 FX FP Issue 08 09 12 FP Door Style Shown 8 4 FX8 FP8 Stove Dimensions ...

Страница 19: ...18 FX FP Issue 08 09 12 Blank Page ...

Страница 20: ...ocal Fireline stove retailer will be pleased to supply spare parts and to provide any other information you require Alternatively contact Fireline 7 Can the doors be left open while burning For safety and heat efficiency the doors should remain closed 8 Why is the stove smoking when lit A flue with back draught problems is almost certainly the cause of a smoking stove Also check adequate ventilati...

Отзывы: