background image

Aarrow Fires Ltd
The Fireworks
Bridport
Dorset, DT6 3BE
Great Britain

Tel. (44) 01308 427234
Fax. (44) 01308 427441
www.aarrowfires.com

The Becton 

MK 3

Range of Gas Stoves

Operating & Installation Manual

PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE

FOR USE IN COUNTRIES

GB & IE

Rev 11

Part No. AFS1125           

(Becton 7 MK 3 Gas Stove)

Содержание Becton 7 MK 3

Страница 1: ...Britain Tel 44 01308 427234 Fax 44 01308 427441 www aarrowfires com The Becton MK 3 Range of Gas Stoves Operating Installation Manual PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE FOR USE IN C...

Страница 2: ...y of our product that we offer a Lifetime Guarantee Should you have any questions about our Becton Stoves that are not covered in this manual please contact the Aarrow dealer in your area or call our...

Страница 3: ...g The Gas Supply 15 Pressure Test Sequence 15 Fire Testing 16 Installation Check List 17 Page SERVICING Details of Pilot Assembly 18 Door Trim 19 Fire Door Glass Seal 19 Burner Assembly 20 Regular Ser...

Страница 4: ...er debris accumulated in and around the appliance This should be performed before and after the installation It is recommended that any replacement item s are not broken up but sealed within a heavy d...

Страница 5: ...All surfaces except the control knob the control door handle and control door are considered to be working surfaces Warning Under no circumstances must the fire be operated if the glass is cracked or...

Страница 6: ...y Natural Gas Becton 7 Natural Gas Main Burner Injector Max Heat Setting Heat Input net 3 7 kW 5 0 kW Gas Rate 0 391m3 hour 0 529m3 hour Cold Setting Pressure 1 5mb 3 5mb Min Heat Setting 2 4 kW 3 3 k...

Страница 7: ...in the right hand side of the fire First position the tall edge into the radius at the front of the fire See Fig 3b below Fig 3b Fitting the R H side lining 3 Then rotate the rear edge until the top f...

Страница 8: ...ide the fire and therefore invalidate the guarantee Ensure the appliance is cold Step 1 Place the base matrix on the matrix plate centrally between the end tabs of the location bar Fig 4a Fig 4a Step...

Страница 9: ...anti clockwise to the pilot position Fig 5b Fig 5b Step 1c Keep the control knob pressed in for a further 15 seconds and then release The pilot will remain alight If pilot does not remain alight repe...

Страница 10: ...to re light the gas for at least three minutes To restart the fire turn the control knob to the off position and repeat the lighting controlling the fire instructions The flame failure device is a sa...

Страница 11: ...should be between 0 05 and 6mb 0 5mm to 6mm water gauge The Bunny requires a minimum flue size of 100mm 4 inches and the Becton 7 requires a minimum flue size of 125mm 5 inches If the stove is being c...

Страница 12: ...de a minimum vertical height of 600mm of flue from the height of the rear flue outlet See figure 7b Closure Plate Connect the flue spigot to the rear outlet Connect a flue extension to the spigot Fit...

Страница 13: ...1 There must be a minimum of 230mm from the rear of the fire to any combustible back wall Fig 7b With a Non combustible back wall the fire can be pushed back until the top diverter touches the wall a...

Страница 14: ...r projection made of wood or any other combustible material is shown on graph 1 Graph 1 Combustible Shelf Clearances The recommended minimum height from the extreme top surface of the fire to the unde...

Страница 15: ...e 1 4 BSP nut and olive with 8mm tubing A maximum pipe run of 1 5 meters or 5 feet should be adhered to and copper tubing may be used provided a distance of 25mm is maintained between pipe work and an...

Страница 16: ...cur the appliance must be disconnected and the flue checked Step 5 If there is an extractor fan in any room this must be turned on and any doors between it and the fire left open repeat the spillage t...

Страница 17: ...raught gas appliances only c If clay or concrete flue liners used confirm that they are correctly jointed with socket end uppermost and state jointing materials used d If an existing chimney has been...

Страница 18: ...s components including the ceramic coal set in a warmer state and assist ignition to the burner This in turn will reduce condensation in the chimney and any associated flue problems The pilot can be v...

Страница 19: ...door on a flat surface and remove the single tab The tracery can now be removed See Fig 11c below Fig 11c Untightening the single tab Step 3 The trim will now lift off the remaining 2 tabs See Fig 11d...

Страница 20: ...i drive screws just inside the fire door aperture The burner assembly will now lift out After replacement of burner assembly ensure that a check on the gas tightness of any new joint is carried out RE...

Страница 21: ...p 8 Inspect the pilot assembly to ensure that it is clean unobstructed and in good order Step 9 Check system for gas soundness Step 10 Replace heat shield and matrix location plate Step 11 Replace fir...

Страница 22: ...Is the thermocouple o k No Is the flue blocked Carry out smoke test Is their a spark at the electrode No Is pilot injector obstructed Clean No No No Turn gas on Purge system Yes Correct pressure No Co...

Страница 23: ...to tone in any connecting flues pipes or surrounding metalwork Tracery or Trim Note When fitted one replaces the other Add on Canopies Bunny Low available only Size 400mm wide x 345mm deep Raises the...

Страница 24: ...24 Becton Bunny Becton 7 mk3 Gas stoves NOTES...

Страница 25: ...Becton Bunny Becton 7 mk3 Gas stoves 25 NOTES...

Страница 26: ...090 AFGS091A AFGS091 AFGS1073 AFGS1073 AFS047 AFS047 1a Becton Bunny mk3 Coal Set 2 Co pilot assembly 3 Elbow Injector 4 Gas Control Valve 5 Magnetic Catch for mk3 Gas Fires 6 Hinge Kit To Fit Either...

Страница 27: ...trol Door Handle Assembly 8 Burner Fixing 9 Pipe Set Complete With Connectors 10 Decorative Door Surround Trim 11 Fire Door Assembly complete with Magnet Lock and Trim 12 Glass Replacement Kit with Ga...

Страница 28: ...e Ceramic Panel Part Description Visual Aid not to scale Bunny mk3 Part No Becton 7 mk3 Part No AFGS094 AFGS094 17 Medium Ceramic Panel 18 Small Ceramic Panel AFGS1084 AFGS1084 AFGS025 AFGS025 AFS1125...

Страница 29: ...ur appliance proves to be defective as a result of faulty materials or workmanship during guarantee we will repair or replace it FREE OF CHARGE as long as the fire has been installed according to the...

Страница 30: ...lease con tact your Aarrow retailer Please keep all repair receipts safely Please ensure you have this manual available when an engineer visits as they will complete the service record chart 30 Becton...

Страница 31: ...ent Documentation must be retained and produced in the event of a warranty claim This guarantee specifically does not cover accidental damage misuse wear tear The use of non Aarrow replacement parts w...

Страница 32: ...nsure installer completes INSTALLATION CHECK LIST details on page 17 of this manual Please ensure the enclosed registration card is completed and returned to Aarrow Fires and the following information...

Отзывы: