background image

REV. 8-9-19  Page 10

AWS Sanctuary 2 & 3 Fire Features

INSTALLING PAN INTO BOWL & WIRING

INSTALLING BURNER PAN INTO BOWL

After the mounting plate is secured inside the bowl, 

attach a flex line to the bottom fitting of the mounting plate 

and the other end to the primary gas supply. 

Install the GOE-30DCV power supply and FG-1420-AOD 

remote control as shown in the wiring diagram (Fig 8). 

Note

:  Ensure the external antenna on the FG-1420-AOD 

receiver is outside the junction box. 

This is a polarity sensitive system.  There is a red sleeve 

attached to the positive (+) side of the DC power supply.  

When wiring the remote control receiver, cut off both 1/4” 

terminals and strip both wire ends. Connect one red wire 

from the receiver to the GOE-30DCV power supply with 

the red sleeve; secure with wire nut. Connect the other red 

wire from the receiver to the + (positive) directly to the red 

wire from the gas valve control box; secure with wire nut.  

See Fig. 8. 

Note: 

An extra red jumper wire is provided to extend either 

one of the red wires of the FG-1420-AOD remote control 

receiver (if needed).  It is not required to use this wire. It 

depends on each application. 

DO NOT CONNECT 120VAC DIRECTLY TO THE GAS 

VALVE WIRES -DAMAGE WILL OCCUR. THIS IS NOT 

COVERED BY WARRANTY.

 

LEARN

Weather 

Proof 

Box

AWS 

Valve Box

GFI Box

+

-

+

GOE-30VDC 

Power Supply

FG-1420-AOD

 Receiver

Fig.

 

8

 

 Wiring diagram.

Note: 

 Use dielectric grease inside of all wire nut 

connections to protect from the outside elements.

 

Plug the GOE-30VDC power supply and remote receiver 

into the 120VAC GFI box. Install battery into the 

transmitter of the FG-1420-AOD and “learn” (program) 

the receiver to the transmitter. Ensure the slide switch on 

the receiver is in the REMOTE position See Fig. 9; Press 

and Release the “learn” button on the receiver.  You will 

hear the receiver emit a short “beep”.  Once this occurs, 

press any button on the transmitter and the receiver will 

emit several rapid beeps confirming the two are programed 

together. 

 

ON

REMOTE

OFF

LEARN

Slide 

Switch

Fig. 9

 1420-AOD slide switch and learn button.

Содержание FPB-26DBSAWS-N-SAN

Страница 1: ...as Description SAN2 34DBSAWSN 38 x 18 Concrete Bowl SAN3 26DBSAWSN 30 x 14 Concrete Bowl Sanctuary 2 Sanctuary 3 THE ROUND FLAT DISC SYSTEM FOR THE SANCTUARY 2 3 COMES WITH A SEPARATE CARTON AND MANUAL HOWEVER USE THIS MANUAL FOR ACTUAL INSTALLATION INTO THE SANCTUARY BOWLS DO NOT DISCARD THIS MANUAL HAS IMPORTANT OPERATING AND MAINTENANCE INSTRUCTIONS LEAVE WITH THE HOMEOWNER MODEL SERIAL Bowls c...

Страница 2: ...re department DANGER WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or other appliances Any LP cylinder not connected for use shall not be stored in the vicinity of this or other appliances WARNING Do not leave unattended during use Do not use for cooking Follow all gas leak procedures in this manual prior to operation WARNING Improper installati...

Страница 3: ...hich is known to the State of California to cause birth defects or other reproductive harm For more information go to www p65Warnings ca gov All media i e lava rock lava stones lava boulders and fire glass has the potential of thermal spalling This is a process that may occur when media is wet and moisture gets trapped inside of the material due to rapid temperature differences When this happens t...

Страница 4: ...8 35 2 18 19 69 15 1 2 SAN3 26DBSAWSN FPB 26DBSAWS N SAN 30 27 2 14 19 69 12 Disclaimer Btu listings are based on 7 0 WC for Natural Gas and 11 0 WC for Liquid Propane LP to the gas valve Flex line size and proper gas pipe sizing will also affect Btu s As a result your Btu s may vary slightly from Table 2 specifications WARNING Proper clearances from combustible materials must be maintained from a...

Страница 5: ...or base then install the GFI box and remote control receiver inside the pedestal or base HARD PIPING TO FIRE FEATURE WITHOUT GAS PROXIMITY NOTE Refer to the NFPA54 National Fuel Gas Code for proper pipe sizing See gas line sizing chart on page 6 of this manual as a reference 1 Turn OFF gas supply system NOTE All gas connections except for brass to brass require the following Clean pipe threads usi...

Страница 6: ...equired for the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper pressure This chart is for reference only we recommend you consult with a Licensed Plumber Gas Fitter or NFPA54 National Fuel Gas Code current edition for more details Length of Pipe in Feet 1 2 3 4 1...

Страница 7: ...low show the difference between a Natural Gas NG and Propane LP orifice LP gas requires ventilation holes at the base of the orifice to provide a cleaner flame See Fig 3 ELECTRICAL INFORMATION Wire Gauge Is the wire gauge correct Wiring must be 12AWG or greater solid or stranded for all installations Note It is recommended to fill the wire nuts with either dielectric grease or silicone prior to in...

Страница 8: ...Ventilation is built into the bottom of each concrete fire feature No additional vents are required WARNING DO NOT BURY THE BOTTOM OF THE CONCRETE BOWL INTO EARTH OR OTHER TYPE OF MEDIA THIS CAN OBSTRUCT AIR FLOW VENTILATION AND VOID FIREGEAR WARRANTY INSTALLATION REQUIREMENTS OF ALL FIRE FEATURES IMPORTANT Installation of Natural or LP gas should be done by a qualified installer service agency or...

Страница 9: ...ate into the bowl Fig 6 Typical MT installation 49 88 BRASS ELBOW CRV BVL2CP BVL2S Key Valve MT FACEPLATE 49 88 BRASS ELBOW Fig 5 Assembled MT mounting plate MT Mounting Plate Detail KEY VALVE ASSEMBLY The figure drawing below shows the MT mounting plate parts and pieces used for the assembly This is pre assembled and ready to install See Fig 5 The Key Valve Assembly consists of 1 key valve and fl...

Страница 10: ...h wire nut See Fig 8 Note An extra red jumper wire is provided to extend either one of the red wires of the FG 1420 AOD remote control receiver if needed It is not required to use this wire It depends on each application DO NOT CONNECT 120VAC DIRECTLY TO THE GAS VALVE WIRES DAMAGE WILL OCCUR THIS IS NOT COVERED BY WARRANTY LEARN Weather Proof Box AWS Valve Box GFI Box GOE 30VDC Power Supply FG 142...

Страница 11: ...rock Sanctuary 3 uses 24 LBS of Firegear Outdoor lava rock Lava rock height should be level and no higher than the top lip of the bowl approximately 2 depth from burner pan Fig 11 MedIa lava rock installation Attach another flex line to the top fitting and connect the other end to the flared fitting of the gas valve box Securely tighten all fittings Install the assembled pan into the bowl as shown...

Страница 12: ...wer vents AWS EXPANED VIEW Hard Pipe Gas Supply Key Valve AWS Burner Pan Assembly Vent Remote Power Supply GFI Box w weather proof cover Remote Receiver w weather proof cover The installation shown above is a Sanctuary 2 Fire Feature The Sanctuary 3 does not have enough room for the GFI power box and the FG 1420 A OD remote receiver they will require external mounting outside of the bowl ...

Страница 13: ... cause severe burns if contacted 2 Do not burn any solid fuels in this appliance READ ALL LIGHTING INSTRUCTIONS BEFORE ATTEMPTING TO LIGHT FIRE PIT CAUTION ENSURE YOU HAVE LEAK TESTED THE FIRE PIT BEFORE OPERATING AND THE TRANSMITTER AND RECEIVER HAVE BEEN LEARNED PROGRAMED TOGETHER FOR WIRELESS OPERATION WARNING Do not stand overtop of fire feature during ignition or operation due to high surface...

Страница 14: ...8 9 19 Page 14 AWS Sanctuary 2 3 Fire Features Junction Box Weatherproof Cover Lid GOE 30DCV SANCTUARY 2 3 REPLACEMENT PARTS 1 2 4 5 3 Drawings No to Scale 12 18 13 14 15 16 17 7 20 21 8 9 11 10 6 OUT 19 22 ...

Страница 15: ...ve flange used with BVSL2S 1 CRV BVL2CP 9 Key Valve 1 BVL2S 10 Flare x MIP Brass Elbow used with BVL2S MT models 2 49 88 11 Air Shutter Orifice Natural Gas NG 1 OAS NG29 12 Air Shutter Orifice Propane Gas LP 1 OAS LP41 13 12 Chrome Plated Key 1 KEY PC 12 14 Ignition Control Box Valve box only 1 FG ICB 15 AWS Pilot Assembly 1 FG PBA 16 30VDC Transformer 1 GOE 30VDC 17 Heat Shield 1 FG HEATSHIELD 18...

Страница 16: ...arance Our products are sealed prior to shipment but the continued care and resealing of the product will be needed every 4 5 years to protect the appearance With a concrete sealant your concrete will look great and natural for many occasions Prolonged contact with overly acidic heavily pigmented or alkali substances should be avoided We recommend cleaning any spills as quickly as possible Take ca...

Страница 17: ...ed directly to the gas valve the controller inside the valve box will be damaged It this happens a burned electrical smell might be present replace controller Connector Not Plugged In Correctly Check the 2 pin connector from pilot to the gas valve Ensure it is plugged into place with the locking latch Pins Not Secure Check the pins inside the 2 pin connector ensure they are not loose If loose push...

Страница 18: ...lide out because is it too tight then it will need to be replaced Debris Debris can get trapped inside the screen of the gas valve Over time rust and other debris can restrict the gas flow on the Outlet screen of the valve that can partially or sometimes even stop the flow Inspect the screen remove it and clean it then replace it Defective Controller or Main Gas Valve If you have inspected the the...

Страница 19: ...ns the trapped gas in the fire feature ignites and you see the Flare Up effect Remove some of the fire glass media from the burner to see if this fixes the problem Gas Leak Natural Gas NG is lighter than air therefore when released into the atmosphere it rises If you have a Natural Gas fire feature and there is a gas leak the Natural Gas NG will rise to the top of the feature Once it encounters th...

Страница 20: ...imary pilot orifice FG PBO LP to convert Natural gas pilot to LP gas Note Requires new LP main burner orifice OAS LP41 sold separately Timer Electric mechanical 2 hour timer Model FG TIMER 2HR Shut Off Valves Model 01 387 OD Flare x FIP Model 01 487 OD Flare x FIP Model 01 266 OD Flare x OD Flare Model 01 288 OD Flare x OD Flare Emergency Stop Model FG EMER STOP Electric emergency shut off Pool Sp...

Страница 21: ... another location or failure to perform normal and routine maintenance Damage due to severe weather conditions such as hail hurricanes earthquakes tornadoes discoloration due to over heating exposure to chemicals including salt either directly or in the atmosphere or very high humidity is not covered by this Limited Warranty There are no other express warranties except as set forth herein For cons...

Страница 22: ... NEED THIS INFORMATION 1 Model Number ___________________________ 2 Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6 What type of media are you using __________________ 7 Review the troubleshooting section in the installation manual 8 What are the symptoms Pl...

Отзывы: