REV. 2-5-18 Page 9
Round Flat Disc Fire Pits
REQUIREMENTS
1. Only non-combustible materials should come in direct contact with any part of the fi re pit. Underneath area should
be non-combustible or a fl at level combustible surface according to the clearances specifi ed in this manual..
2. Refer to the NFPA54 (National Fuel Gas Code) for proper pipe sizing. See gas pipe sizing chart on page 7.
3. Determine the size of the round fi re pit you are preparing to install (Refer to page 4).
4. You must provide a round opening cut-out opening to place the fl at disc onto the non-combustible enclosure. Do not
exceed the maximum opening from Table 1, dimension B located on page 4.
5. Follow the local code requirements for the gas type being used. This fi re pit should be installed in accordance with
local codes and ordinances or in the absence of local codes, with the latest National Fuel Gas Code, ANSI Z223.1
NFPA54 or CSA B149.1, Natural and Propane Installation Code in Canada.
6. Fire pits create high temperatures, it is very important to have any combustibles at a safe distance. Refer to page 4.
7.
CAUTION: A minimum of 18 square inches of cross ventilation (per side) is required to keep the inside of the
enclosure dry. We recommend installation of a VENT-KIT-6x12. See accessory section.
8. These products are designed for outdoor use only. Not approved for any indoor use.
9. This fi re pit is designed to have lava rock completely covering the spur burner, so that the burner is not visible. Do
not cover more than 1” above the top of the burner. When purchasing lava rock use 1” to 2” diameter as a base to
cover the fl at disc.
10. Gas lines and fi ttings must be installed in to the non-combustible structure. All gas connections must be leak tested
before installation of the fi re pit. Soapy water leak detection is required before regular use of the fi re pit.
11. Do not use material that will absorb moisture over time and will not release this moisture quickly. Moisture can boil
in this material and can rapidly break apart and cause damage or personal injury.
12. Never leave any other combustible material on top of the fi re pit. This could cause unsafe operation of this system
and damage to the component that will not be covered under our warranty.
13 .
Ensure proper water drainage is also incorporated into the fi re pit enclosure.
INSTALLATION OF FIRE PIT INTO AN APPROVED ENCLOSURE
SECTION
A - MA
TCH LIGHT (MT) INST
ALLA
TION
Flat disc’s are typically used with landscape blocks. The illustrations below show examples of possible installations.
ON
O
FF
ON
O
FF
Fig.4
Shows disc secured under stone caps.
Fig. 5
Shows disc secured between layer of block.
Fig. 6
Shows blocks supporting center of disc.
Fig. 7
Shows blocks supporting an oversized opening.
Содержание FPB-20DBSMT-N
Страница 8: ...REV 2 5 18 Page 8 Round Flat Disc Fire Pits Section A Match Light MT Installation ...
Страница 14: ...REV 2 5 18 Page 14 Round Flat Disc Fire Pits Section B Thermocouple Manual Safety TMSI Installation ...
Страница 20: ...REV 2 5 18 Page 20 Round Flat Disc Fire Pits Section C Thermocouple Flame Sense TFS Installation ...
Страница 30: ...REV 2 5 18 Page 30 Round Flat Disc Fire Pits Replacement Parts Accessories ...
Страница 37: ...REV 2 5 18 Page 37 Round Flat Disc Fire Pits NOTES ...