REV. 2-5-18 Page 18
Round Flat Disc Fire Pits
FIRE PIT MAINTENANCE
1. The fire pit should be inspected and cleaned before initial use at least annually by a qualified field service person.
2. Any component that is found faulty must be replaced with an approved component.
3. Any tampering or modifying with the fire pit is dangerous and voids all warranties.
4. During winter months in cold climates and various seasons operation the fire pit may be affected by weather
conditions. It is recommended to use a cover/lid overtop of your fire pit to protect it from humid/rainy weather
conditions when not in use. Heavy rains/downpours could affect the fire pit operation if not covered; if this
occurs ensure you allow the fire pit time to dry out before attempting to operate.
NOTE
: If a combustible type cover is
used over the fire pit when not in use be sure to remove it before operation to prevent a severe safety hazard.
5. Carbon (soot) may build up on the surface of logs (if installed) during heavy use. Sooting may also occur periodically
on the screen of the ignitor hood. To clean, brush off with a dry bristle brush or cloth. Keep soot away from clothing or
furniture.
6. Over time stainless steel parts can discolor when heated, usually a golden or brown hue. This
discoloration is normal and does not affect the performance of the appliance.
TMSI TROUBLE SHOOTING
Symptom
Remedy
Fire pit won’t light
1. Bleed gas line.
3. Ensure all gas supply lines are turned ON.
4. Ensure there is not too much media overtop of burner; it can inhibit gas from flowing.
Low Flame
1. Ensure the base media is at least 1-inch in diameter and top media is no more than 1-inch over
top of burner.
2. Ensure all shut-off valves and valve is fully open. .
3. Check for spider webs inside burner orifice.
Water in my fire pit
1. Excess dust/sand material from media may be blocking the weep holes to relieve water.
Remove all media and unplug weep holes. Clean or install new media free of dust and dirt.
2. Ensure fire pit enclosure has proper drainage for water and proper ventilation to dry out.
3. Recommend to purchase a cover/lid to keep excessive water out of the fire pit.
Whistling Noises
1. Check media to ensure it is not too tightly packed around the burner tube.
2. Ensure a non-whistling flex connector is being used.
Fire pit won’t stay lit
1. Check alignment of thermocouple over rainshield on page 16, Fig.16
2. Ensure thermocouple is not screwed too tight into gas valve. It should be finger tight plus a
quarter turn with a wrench.
3. Ensure thermocouple is clean and free of any debris. Excessive soot can be an issue.
SECTION B THERMOCOUPLE MANUAL
SAFETY
(TMSI) INST
ALLA
TION
Содержание FPB-20DBSMT-N
Страница 8: ...REV 2 5 18 Page 8 Round Flat Disc Fire Pits Section A Match Light MT Installation ...
Страница 14: ...REV 2 5 18 Page 14 Round Flat Disc Fire Pits Section B Thermocouple Manual Safety TMSI Installation ...
Страница 20: ...REV 2 5 18 Page 20 Round Flat Disc Fire Pits Section C Thermocouple Flame Sense TFS Installation ...
Страница 30: ...REV 2 5 18 Page 30 Round Flat Disc Fire Pits Replacement Parts Accessories ...
Страница 37: ...REV 2 5 18 Page 37 Round Flat Disc Fire Pits NOTES ...