background image

12

LIGHTING INSTRUCTIONS

UNITS WITH SAFETY PILOT continued

LIGHTING THE BURNER SYSTEM

11- To manually light the burner system, gently press and turn

the gas control knob, in a counter-clockwise direction, to
the “ FULL ON “ position. Gas should ignite within
approximately five ( 5 ) seconds. Adjust burner flame by
opening or closing manual gas shut-off valve.

FOR UNITS WITH REMOTE SYSTEMS

See the instructions that are packaged with the remote, and/or
instructions on Page 7, of this manual.

WARNING:

If ignition does not take place,

TURN THE GAS

OFF

, at the manual shut-off valve, and wait five ( 5 ) minutes,

before attempting to relight the appliance. If after repeated
attempts, the appliance does not ignite, contact your installer,
or the

fire

gear Service Center.

PILOT FLAME ADJUSTMENT

FIGURE 25

The pilot flame should be a soft blue in color, and should
surround the last 1/2” of the thermocouple tip. The pilot
adjustment screw is located on the valve, just to the right of the
control knob. ( SEE FIGURE 22 )

If the pilot flame must be adjusted, use a standard slotted
screwdriver to turn the screw clockwise to reduce the flame, or
counter-clockwise to increase the flame.
( SEE FIGURE 22 & 25 )

MAINTENANCE & SERVICE

Your

fire

gear FIRE ISLAND HEARTH SYSTEM should be

thoroughly inspected on a regular basis, at least once a year,
by a qualified installer.

At the beginning of each heating season, the system should be
checked as follows:

1-

Check the chimney flue or vent pipe to make sure that the
flue is drawing properly, and that any vent pipe
connections are tight.

2-

Check to see that there are no blockages at the chimney
or vent termination.

3-

Check for creosote, or soot build up in chimney or vents,
and clean if necessary.

4-

Pilot and burners should be inspected annually, at the
beginning of each heating season.

ADJUSTMENTS

The burner system has been adjusted for proper operation at
the factory. No adjustment is necessary, other than altitude
de-rate, or pilot flame.

NEVER enlarge valve orifices or burner ports.

PILOT FLAME

MUST SURROUND

THERMOCOUPLE

TIP AS SHOWN

PILOT FLAME

THERMOCOUPLE

Содержание BFI18-SSMN

Страница 1: ...ence INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference WARNING If the information in this manual is not followed exactly a fire or explosion may result ca...

Страница 2: ...cer birth defects and or other reproductive harm This warning is issued pursuant to California Health Safety Code Sec 25249 6 While this appliance is not in use the gas must be turned off at the gas s...

Страница 3: ...ATURAL GAS RATED PRESSURE 7 0 W C MINIMUM GAS MAXIMUM GAS ORIFICE BTU HR PRESSURE PRESSURE SIZE INLET 7 0 W C 10 5 W C 13 90000 FIREGEAR FIRE ISLAND HEARTH SYSTEM SPECIFICATIONS with VALVE SAFETY PILO...

Страница 4: ...r wall of the fireplace If this is not performed drafting may cause pilot outage or sooting Use a heat resistant sealant DO NOT seal the chimney flue damper WARNING Gas supply system must be installed...

Страница 5: ...the wrench on the gas cap in a counter clockwise direction 4 Clean the pipe threads on the gas stub using either a wire brush or steel wool Apply Teflon tape or pipe dope to the steel fittings before...

Страница 6: ...Using an adjustable wrench and turning in a clockwise direction attach a 1 2 Female Flare X 3 8 Male Flare Brass Reducer Fitting included on some models to the gas stub 4 Using two adjustable wrenches...

Страница 7: ...r your distance run 1 The wire harness should already be installed in the terminal block on the rear of the remote receiver FOR HAND HELD TRANSMITTER REMOTE RECEIVERS SEE FIGURE 13 14 FOR WALL SWITCH...

Страница 8: ...REMOTE RECEIVERS USE THE OUTSIDE TERMINAL BLOCK RECEPTACLES SEE FIGURE 13 14 WALL MOUNT REMOTE RECEIVER See the instructions packaged with the remote system for directions on programming Learning both...

Страница 9: ...s medium over the entire burner filling the burner pan The glass medium should follow the slope of the burner pan covering the burner completely SEE FIGURE 18 FIGURE 18 2 Pour the decorative sand arou...

Страница 10: ...WITH VALVE FRONT VIEW WARNING Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and replace any part of the control s...

Страница 11: ...smell gas STOP 7 Turn off the gas at the manual shut off valve and recheck all gas connections for leaks Do not continue until all leaks are corrected Once you are assured that there are no leaks pro...

Страница 12: ...lve just to the right of the control knob SEE FIGURE 22 If the pilot flame must be adjusted use a standard slotted screwdriver to turn the screw clockwise to reduce the flame or counter clockwise to i...

Страница 13: ...X 3 8 FLARE 50 12 38FL STUB FITTING BRASS ELBOW 1 2 NPT F X 3 8 M FLARE IM FIHS INSTRUCTION MANUAL FIRE ISLAND SERIES FG SAND B OPTIONAL FIRE ISLAND SERIES BLACK SAND LG H210 OPTIONAL FIRE ISLAND SERI...

Страница 14: ...E KNOB EXTENSION FIREGEAR HAND HELD REMOTE SYSTEMS FG LT2 HAND HELD ON OFF REMOTE FG LMF M HAND HELD ON OFF VARIABLE FLAME REMOTE FIREGEAR WALL MOUNT REMOTE SYSTEMS FG WS LT WIRED WALL SWITCH FG WWS L...

Страница 15: ...eck gas supply pressure while pilot remains on Faulty Valve Replace Valve Faulty pilot or thermocouple Replace Safety Pilot Clogged or dirty burner ports Clean burner ports Burner pilot light but will...

Страница 16: ...failures or operating difficulties due to accident abuse misuse alteration misapplication vandalism improper installation or improper maintenance or service or failure to perform normal and routine m...

Отзывы: