SAFETY INFORMATION continued
FIGURE 1
!!! WARNING !!!
The damper clamp must be installed in a manner which will maintain
the minimum permanent damper vent opening at all times. SEE
FIGURE 1. See the Decorative Gas Log Set Specifications on page 3.
!!! WARNING !!!
The State of Massachusetts requires that the chimney flue damper,
when used with decorative gas log sets, be welded open or completely
removed. In the Commonwealth of Massachusetts, this appliance
must be installed by a licensed plumber or gasfitter.
!!! WARNING !!!
Improper installation, adjustment, alteration, service or maintenance,
can cause property damage, personal injury or loss of life. Refer to the
owner’s information manual, provided with this appliance. Installation
and service must be performed by a qualified installer, service agency
or the gas supplier.
FIREGEAR ADVANTAGE BURNER SERIES
HEARTH KIT SPECIFICATONS
21” & 24” HEARTH KITS WITH VALVE
NATURAL GAS -
RATED PRESSURE – 7.0” W.C.
MINIMUM GAS
MAXIMUM GAS
ORIFICE
BTU/HR
PRESSURE PRESSURE SIZE
INLET
7.0” W.C.
10.5” W.C.
#
85,000
LIQUID PROPANE
- RATED PRESSURE – 11.0” W.C.
MINIMUM GAS
MAXIMUM GAS
ORIFICE
BTU/HR
PRESSURE PRESSURE SIZE
INLET
11.0” W.C.
13.0” W.C.
#35
75,000
FIREGEAR ADVANTAGE BURNER SERIES
HEARTH KIT SPECIFICATIONS continued
30” HEARTH KITS WITH VALVE
LIQUID PROPANE -
RATED PRESSURE – 11.0” W.C.
MINIMUM GAS
MAXIMUM GAS
ORIFICE
BTU/HR
PRESSURE PRESSURE SIZE
INLET
11.0” W.C.
13.0” W.C.
#31
85,000
36” & 42” HEARTH KITS WITH VALVE
LIQUID PROPANE
- RATED PRESSURE – 11.0” W.C.
MINIMUM GAS
MAXIMUM GAS
ORIFICE
BTU/HR
PRESSURE PRESSURE SIZE
INLET
11.0” W.C.
13.0” W.C.
#29
95,000
HIGH ALTITUDE DERATE
In the U.S.A., input BTU shall be de-rated 4% ( 1 orifice size )
per 1000 ft. for altitudes above 2000 ft.. In Canada, input BTU
shall be de-rated 10% ( 2 orifice sizes ) at altitudes from 2000
ft. to 4500 ft..
NOTE: NATURAL GAS MATCH THROW SETS, MAY BE
USED IN SOME AREAS. CHECK YOUR LOCAL CODES
FOR THIS CONFIGURATION!
MINIMUM FIREPLACE DIMENSIONS
MASONRY BUILT FIREPLACES
Chimney Height minimum of 6 feet
LOG FRONT DEPTH HEIGHT MINIMUM
SET
WIDTH IN
IN
IN
VENT IN
SIZE INCHES INCHES INCHES SQ
INCHES
21” 24” 15” 18”
71.4
sq.
in.
24" 30" 15" 18"
71.4
sq.
in.
30" 36" 15" 18"
71.4
sq.
in.
36” 42” 15" 18"
93.5
sq.
in.
42” 48” 15" 18"
93.5
sq.
in.
MINIMUM FIREPLACE DIMENSIONS
FACTORY BUILT FIREPLACES
Chimney Height minimum of 15 feet
LOG FRONT DEPTH HEIGHT MINIMUM
SET
WIDTH IN
IN
IN
VENT IN
SIZE INCHES INCHES INCHES SQ
INCHES
21” 24” 15” 18”
45.4
sq.
in.
24” 30" 15" 18"
45.4
sq.
in.
30” 36" 15" 18"
45.4
sq.
in.
36” 42” 15" 18"
50.3
sq.
in.
42” 48” 15" 18"
50.3
sq.
in.