background image

 12

HAND HELD REMOTE RECEIVER 

 
See the instructions, packaged with the remote system for directions 
on programming the coding switches on both transmitter and receiver. 
 

 

 

FIGURE 29 – HAND HELD REMOTE RECEIVER – FRONT VIEW 

 

 

 

FIGURE 30 – HAND HELD REMOTE RECEIVER – REAR VIEW 

 

 

 

FIGURE 31 – HAND HELD REMOTE RECEIVER - TOP VIEW 

 

IMPORTANT 

 

TERMINAL BLOCK CONNECTIONS, FOR HAND HELD 

TRANSMITTER, REMOTE RECEIVERS, USE THE OUTSIDE 

TERMINAL BLOCK RECEPTACLES.  ( SEE FIGURE 30 & 31) 

 
 
 
 
 
 
 
 
 

WALL MOUNT REMOTE RECEIVER 

 

See the instructions, packaged with the remote system for directions 
on programming, (“Learning”) both transmitter and receiver. 

 

 

 

FIGURE 32 – WALL MOUNT & VARIABLE FLAME  

REMOTE RECEIVER - FRONT VIEW 

 

 

 

FIGURE 33 – WALL MOUNT & VARIABLE FLAME  

REMOTE RECEIVER - REAR VIEW 

 

 

 

FIGURE 34 – WALL MOUNT & VARIABLE FLAME  

REMOTE RECEIVER - TOP VIEW 

 

IMPORTANT 

 

TERMINAL BLOCK CONNECTIONS, FOR WALL MOUNT 
TRANSMITTER, REMOTE RECEIVERS, USE THE INSIDE 

TERMINAL BLOCK RECEPTACLES.  ( SEE FIGURE 33 & 34 ) 

 
 
 
 
 
 
 
 
 

CODE SWITCHES 

Содержание ADVANTAGE SERIES

Страница 1: ...ng or operating this gas appliance These instructions should be left with the homeowner for future reference WARNING If the information in this manual is not followed exactly a fire or explosion may r...

Страница 2: ...must be turned off at the gas supply DO NOT ATTEMPT TO DISCONNECT THE GAS OR ANY GAS FITTING WHILE THIS APPLIANCE IS IN OPERATION NEVER leave the decorative gas log set unattended while in operation N...

Страница 3: ...C 13 0 W C 35 75 000 FIREGEAR ADVANTAGE BURNER SERIES HEARTH KIT SPECIFICATIONS continued 30 HEARTH KITS WITH VALVE LIQUID PROPANE RATED PRESSURE 11 0 W C MINIMUM GAS MAXIMUM GAS ORIFICE BTU HR PRESSU...

Страница 4: ...the floor or wall of the fireplace If this is not performed drafting may cause pilot outage or sooting Use a heat resistant sealant DO NOT seal the chimney flue damper WARNING Gas supply system must...

Страница 5: ...ning on page 3 of this manual IMPORTANT BEFORE YOU BEGIN Insure that the fire box meets the minimum specifications of the appliance see the specifications beginning on page 3 of this manual IMPORTANT...

Страница 6: ...and one wrench on the fitting remove the existing cap or gas jet assembly from the gas stub in your fireplace by turning the wrench on the gas cap in a counter clockwise direction 4 Clean the pipe th...

Страница 7: ...rom both side to side and front to back The unit is shipped ready for rear gas connection only SEE FIGURE 2 3 2 Bend a 3 8 gas line with two 2 3 8 brass female flare fittings included on some models t...

Страница 8: ...following 1 Place the burner upside down with the tines facing away from you on the floor outside of the fireplace SEE FIGURE 15 2 Locate the two 2 valve bracket mounting holes on the right hand side...

Страница 9: ...ne screws mount the valve to the valve shield in the angled hole position SEE FIGURE 21 10 Using an adjustable wrench and turning in a clockwise direction assemble the main flex gas line to the burner...

Страница 10: ...rass reducer fitting 5 Using two adjustable wrenches and turning in a clockwise direction attach the other end of the gas line to the brass fitting on the valve assembly One wrench on the gas line fit...

Страница 11: ...or your distance run 1 The wire harness should already be installed in the terminal block on the rear of the remote receiver FOR HAND HELD TRANSMITTER REMOTE RECEIVERS SEE FIGURE 30 31 FOR WALL SWITCH...

Страница 12: ...REMOTE RECEIVERS USE THE OUTSIDE TERMINAL BLOCK RECEPTACLES SEE FIGURE 30 31 WALL MOUNT REMOTE RECEIVER See the instructions packaged with the remote system for directions on programming Learning both...

Страница 13: ...njury IMPORTANT Cover the pilot and valve assembly and for Liquid Propane units the air mixer at the rear of the burner to protect it before installing Glass and Glowing Embers 1 Pour the provided Gla...

Страница 14: ...ogs proceed to the operation section on page 14 for Match Throw Units and page 15 for units with gas control valve OPERATION LIGHTING INSTRUCTIONS MATCH THROW UNITS FOR YOUR SAFETY READ BEFORE LIGHTIN...

Страница 15: ...re provided the screen shall have an opening s for introduction of combustion air WARNING When this decorative gas appliance is used in a fireplace equipped with a combustion air kit and glass doors t...

Страница 16: ...SEE FIGURE 39 If the pilot flame must be adjusted use a standard slotted screwdriver to turn the screw clockwise to reduce the flame or counter clockwise to increase the flame SEE FIGURE 39 42 CURING...

Страница 17: ...000S AMERICAN FLAME SOLENOID SPI E61 N WHITE ROGERS E61 SAFETY PILOT NATURAL GAS SPI E61 P WHITE ROGERS E61 SAFETY PILOT LIQUID PROPANE AMOR 35 LIQUID PROPANE AIR MIX ORIFICE 35 21 24 UNITS AMOR 31 LI...

Страница 18: ...E KNOB EXTENSION FIREGEAR HAND HELD REMOTE SYSTEMS FG LT2 HAND HELD ON OFF REMOTE FG LMF M HAND HELD ON OFF VARIABLE FLAME REMOTE FIREGEAR WALL MOUNT REMOTE SYSTEMS FG WS LT WIRED WALL SWITCH FG WWS L...

Страница 19: ...ure Check gas supply pressure while pilot remains on Faulty Valve Replace Valve Faulty pilot or thermocouple Replace Safety Pilot Clogged or dirty burner ports Clean burner ports Burner pilot light bu...

Страница 20: ...arranty does not cover any failures or operating difficulties due to accident abuse misuse alteration misapplication vandalism improper installation or improper maintenance or service or failure to pe...

Отзывы: