3.4 Troubleshooting
Issue
Possible cause(s)
Suggestion
The Main Isolator switch is
on, but the consumers are
not receiving any power
The AC Output Protection
may not be switched on
Check that the AC Output
Protection Switch
“Fig. 1 -
Control Panel” on page 9
is pushed up to the on
position.
The AC Output Protection
Switch (
“Fig. 1 - Control
Panel” on page 9
) keeps
tripping
There is an electrical fault
with the consumers
connected to the AC
output
Check the electrical integrity
of the wiring and consumers
being connected to the
unit’s AC output.
Connected consumers are
drawing too much power for
the rated output of the unit
Refer to the maximum
output rating on the unit’s
rating plate and reduce the
total power draw
accordingly.
When switching the Inverter
on with the Inverter On/Off
switch, its red LED
illuminates, but the green
AC Output Indicator does
not illuminate.
The AC Output Protection
Switch is in the off position.
Switch the AC Output
Protection Switch
“Fig. 1 -
Control Panel” on page 9
into the on position. (Check
above points if the AC
Output Protection switch
continues to trip.)
Input (e.g. battery charger,
solar array) is connected
and operating correctly but
the batteries are not being
charged.
The Main Isolator switch is
in the off position.
Switch the Main Isolator
switch
“Fig. 1 - Control
Panel” on page 9
into
the on position.