4.1.2
connecting The First Battery Extender Module to Pyxis
1.
An interconnecting link lead is supplied with each Battery Extender
Module.
2.
Connect one end of the link lead to the Battery Extension & 12 V DC
Charging connector on the Pyxis control panel.
3.
Connect the other end of the link lead to one of the Battery Extender
Module 12 V DC In/Out connectors (it does not matter which is used.)
It is possible to connect and disconnect the Battery Extender
Module while the Pyxis unit is providing power to
consumers. This allows “hot swapping” of Battery Extender
Modules.
4.1.3
connecting Additional Battery Extender Modules to Pyxis
1.
A link lead is supplied with each Battery Extender Module.
2.
Connect one end of the interconnecting cable to the Battery Extension
& 12V DC Charging connector on Pyxis
3.
Connect the other end to one of the Battery Extender Module 12 V DC
In/Out connectors (it does not matter which is used.)
4.1.4
charging Battery Extender Modules
Battery Extender Modules can be charged while connected to Pyxis or on their
own. Multiple Battery Extender Modules can be charged simultaneously by
connecting them together using the interconnecting cable. Refer to
“3.2 Charging
Methods” on page 13