Firefly Cygnus CYG2400/1380/24 Скачать руководство пользователя страница 5

 

 

  

 

Cygnus  User  Manual  

-

    v3.0            2011  

 

Page  5

 

1.3

 

Standards  &  Regula ons

 

The  Cygnus  Portable  Solar  Generator  conforms  to  the  following  standards  and  regula ons:

 

Manufactured  in  compliance  with  ISO  9001:2008

 

LVD  73/23/EEC

 

EN  61000

-

6

-

1,  EN  61000

-

6

-

3,  EN  55014

 

IP23

 

WEEE  Direc ve

 

        

 

1.4

 

Disposal  &  Recycling

 

The  Cygnus  Portable  Solar  Generator  comprises  of  components  that  must  disposed  of  responsibly.  For  the  sake  of  the  
environment  many  of  the  components  within  the  unit  can  be  recycled  or  reused.  Firefly  Solar  Generators  Ltd.  will  en-­‐
sure  the  safe  decommissioning  and  recycling  of  the  unit  at  no  charge  if  the  unit  is  returned  to  the  manufacturer.  Other-­‐
wise,  please  contact  the  manufacturer  for  more  informa on  on  safe  and  proper  decommissioning  of  your  Cygnus  Porta-­‐
ble  Solar  Generator.

 

 

1.5

 

Firefly  Solar  Contact  Details

 

 

1.6

 

About  Firefly  Solar

 

Firefly  Solar  is  the  European  market  leader  in  the  design  and  manufacturer  of  off

-

grid,  portable  and  permanent  solar

-

powered  generators.  Our  green  energy  products  and  services  meet  the  needs  of  environmentally  concerned  individuals  
and  organisa ons  who  are  looking  to  reduce  the  carbon  emissions  caused  by  the  use  of  fossil  fuels  and  diesel  powered  
equipment.

 

Firefly  Solar  generators  harness  energy  supplied  by  the  sun  using  photovoltaic  (PV)  cells,  storing  it  for  when  it’s  needed.  

 

Addi onally,  mul

-

charge  inputs  allows  kine c  and  wind  energy  to  be  stored  for  convenient  use.  We  are  specialists  in  

green  energy  storage  systems  –  our  exper se  in  ba eries,  electronics  and  so ware  has  enabled  our  generators  to  over-­‐
come  many  of  the  problems  of  intermi ency  which  can  be  associated  with  renewable  energy  sources.

 

Firefly  Solar  generators  can  provide  an  uninterrupted  electrical  supply  even  in  the  absence  of  light  or  other  charging  
input.  Our  award

-

winning  products,  which  include  the  Orion,  Cygnus,  Pictor  &  Pyxis  models,  have  been  widely  used  by  

well

-

known  brands  such  as  Coca

-

Cola  Enterprises,  the  BBC,  Sky,  Greenpeace,  Friends  of  the  Earth  and  Solar  Aid.

 

Firefly  Solar  provide  temporary  stand

-

alone  power  for  the  events,  broadcast,  and  construc on  industries;  permanent  

stand

-

alone  power  for  rural  loca ons  and  telecommunica ons;  and  back

-

up  (UPS)  power  with  extended  run   mes  for  

loca ons  with  intermi ent  grid  connec vity.  Firefly  Solar  power  genera ng  equipment  is  zero  emission,  true  silent  run-­‐
ning  and  eliminates  the  need  for  inflammable  fuel.

 

Firefly  Solar  Generators  Ltd

 

The  Green  Warehouse

 

Court  Farm  House

 

King  George  VI  Avenue

 

Hove

 

East  Sussex

 

BN3  6XJ

 

United  Kingdom

 

Tel:  +44  (0)  1273  617  006

 

Fax:  +44  (0)  1273  316  646

 

 

E

-

mail:  info@fireflysolar.net

 

Web:  www.fireflysolar.net

 

Содержание Cygnus CYG2400/1380/24

Страница 1: ...ual v3 0 2011 Page 1 Cygnus Portable Solar Generator User Manual v3 0 2011 For use with the following models CYG2400 460 24 CYG2400 920 24 CYG2400 1380 24 CYG3500 920 24 CYG3500 1380 24 CYG5000 920 24...

Страница 2: ...8 2 4 3 Connect the Output Power Cables 9 3 General Opera on 10 3 1 Turning the Power On 10 3 2 Monitoring the Power 11 3 2 1 Displaying Real me Ba ery Bank Voltage 11 3 2 2 Displaying the Ba ery Bank...

Страница 3: ...nected to Single Cygnus 26 6 4 Appendix 4 Troubleshoo ng Guide 27 6 5 Appendix 5 Technical Data 28 6 6 Appendix 6 Further Reading 29 Figures Fig 1 Cygnus Control Panel Component Reference 7 Fig 2 RCC0...

Страница 4: ...will be referred to as The manufacturer The Cygnus Portable Solar Generator will be referred to as Cygnus or Unit Any items that consume power will be referred to as Consumers State of Charge of the b...

Страница 5: ...Fire y Solar generators harness energy supplied by the sun using photovoltaic PV cells storing it for when it s needed Addi onally mul charge inputs allows kine c and wind energy to be stored for conv...

Страница 6: ...t weights 3 It is recommended that the unit is secured using suitable straps when in transit to prevent it from moving 2 2 2 Loading Unloading 1 Cygnus must be loaded or unloaded using the correct equ...

Страница 7: ...OC C2 RCC 03 Displays real me informa on on inputs and outputs also allows their adjustment C3 Open Terminate Switch Used when mul ple Cygnus Portable Solar Generators are linked together C4 Power On...

Страница 8: ...r manuals can also be downloaded from the manufacturer s website at www re ysolar net It is also possible to operate the unit only using the internal ba ery bank without external inputs connected When...

Страница 9: ...ial CEEform socket for the connec on of AC power out to consumers requiring Fig 1 E2 1 Before any power connec ons are made ensure that both the RCD Fig 1 B1 and MCB Fig 1 B2 are switched O 2 Plug in...

Страница 10: ...p will be heard and the RCC 03 Fig 1 C2 backlight will illuminate 5 The unit is now in standby mode 6 Message 012 use of ba ery temperature sensor will be displayed for ve seconds 7 A er which the fol...

Страница 11: ...a ery life le in the unit E g C75 indicates that there is 75 ba ery capacity remaining If the 30 lower limit is reached the Smartgauge s internal alarm will be triggered and its display will ash betwe...

Страница 12: ...SC on the RCC 03 Fig 1 C2 Turn the System O will be displayed 2 Press SET to accept The unit will then go into standby mode 3 To fully shut down the unit press the On O Bu on Fig 1 C4 on the control p...

Страница 13: ...n the standard models The relays can ac vate external alarms and automa c start relays for second ary power systems and can be added as an op onal extra Please contact the manufacturer for further inf...

Страница 14: ...he control panel If using a second Fold Array parallel junc on box to connect mul ple arrays connect its output to the Solar Array 2 connectors 6 The LED indicator to the right of the connectors will...

Страница 15: ...connector from the unit Refer to Appendix 2 6 2 2 for further informa on on using the SPEC Pak connector 2 Disconnect the remaining cables and any junc on boxes 3 7 3 Charging with AC Grid Supply or S...

Страница 16: ...d be set as open Fig 1 C3 rotate switch an clockwise and Cygnus 2 as Termi nated Fig 1 C3 rotate switch clockwise 4 If using three units Cygnus 1 and Cygnus 2 should be set as Open Fig 1 C3 rotate swi...

Страница 17: ...and the third L3 Do not a empt to connect the units in series if this is not the case 3 Once the unit numbers have been determined posi on the three units with L1 on the le L2 in the centre and L3 on...

Страница 18: ...in the On posi on and none of them have tripped out 4 4 Turning O The Units 1 Using the RCC 03 Fig 1 C2 of Cygnus 1 Press Up then Down to wake up the control panel 2 Press the Esc bu on to choose to...

Страница 19: ...s can be obtained from the manufacturer 5 4 Tes ng It is recommend that the unit should be tested annually for safety by a quali ed electrician Local regula ons may require more frequent tes ng Please...

Страница 20: ...to adjust the se ng 4 Use the arrow keys to input the required voltage A maximum of 245V is available Press SET to accept 5 Press ESC to navigate back to the main menu and the arrow keys to return to...

Страница 21: ...e adapters and appliances 6 2 1 Connec ng the SPEC Pak Plug 1 The SPEC Pak socket is ed with a waterproof cover Fig 5 Step 1 2 Remove the cover by hinging up the retaining clip and pulling out Fig 5 S...

Страница 22: ...nected to the AC output socket The ba eries are kept at full capacity and are only used if there is a break in input voltage Fig 6 Example Showing A Single Unit Connected To An AC Feed and Powering Co...

Страница 23: ...sumers and any surplus power keeps the ba eries topped up Ba ery power is used when the consumers require more power than the solar arrays are genera ng Fig 7 Example Showing Arrays Directly Connected...

Страница 24: ...3 3 Three Phase Cygnus System Three pre con gured units are connected by means of data cables and a series junc on box available separately from the manufacturer Fig 9 Example Showing the Use of Thre...

Страница 25: ...11 Page 25 6 3 4 Two Unit Parallel Cygnus System Two units are connected by means of a data interlink cable and a parallel junc on box available separately Fig 10 Example Showing the use of Two Units...

Страница 26: ...al v3 0 2011 Page 26 6 3 5 Kinectrics PedGen Connected to Single Cygnus Fig 11 Example Showing the use of Two Kinectrics Units to Charge Cygnus Fig 12 Example Showing the use of Eight Kinectrics Units...

Страница 27: ...t s will automa cally switch out of this mode and the indi cators should stay on as long as power is being used Message on RCC 03 Ba ery Voltage Too Low This indicates that the voltage has reached its...

Страница 28: ...Solar Generator range To nd the relevant informa on for your unit please refer to the model number on its ra ng plate at the bo om of the le hand panel or the main graphics on each side of the unit T...

Страница 29: ...uso 20Xtender 20serie 20 It pdf RCC 03 English h p www studer innotec com upload temp RCC 02 03 20User 20manual pdf French h p www studer innotec com upload temp Manuel 20u lisateur 20RCC 02 03 pdf G...

Отзывы: