Page 13
CYGHPG-User-Manual-v2
2.4.2 Input Options
The unit can accept inputs from an AC power source (single phase or three
phase. Further information on connecting these items is available in section
"3.2
Charging From An AC Supply" on page 22
) and solar arrays using the optional
Solar Prep kit.
The AC input current is adjustable, allowing the unit to be charged from AC
sources with lower current capacities. It is also necessary to adjust the input
current when switching between some modes.
Adjusting Input Current
1.
Open the control centre door using the supplied key- see
"Fig. 6 - 5 mm
Double Barb Key" on page 17
2.
Ensure that the unit is switched on
3.
Press the down button to wake up the control centre
4.
Press the down button repeatedly until the “Xtender settings” screen is
displayed:
5.
Press “SET”: “BASIC SETTINGS” is displayed:
W A r N I N G
Care must be taken to ensure
that the correct connections
are made to avoid the risk of
electrocution or possible
damage to the unit’s internal
components.
Ensure that the cumulative
power
of
connected
consumers does not exceed
the maximum power output of
your unit. Refer to the rating
plate to ascertain the unit’s
maximum power output.
All
connected
cables,
distribution and consumers
must be fit for purpose– refer
to the consumers’ rating plates
and manuals to ascertain the
required input.