![FireBird Enviromax Kitchen C12 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/firebird/enviromax-kitchen-c12/enviromax-kitchen-c12_technical-manual_2291246020.webp)
6
18
6.5 INSTALLATION - FLUE REGULATIONS
A
G
E
B
C & D
K
F
F
L
N
O
P
H
J
Boundary
Boundary
F
Q
Q
Q
Q
Q
Q
Q
R
Clearances advised by BS 5410 Part 1: 2014
Regular Appliance (Open, Low Level Discharge and Balanced) Flue Termination Clearance
The basic requirement with regard to flue positioning is that no hazard or nuisance is caused by the flue gases.
Diagrams 20a and 20b show clearances advised by BS 5410 Part 1: 2014.
Regional requirements where flue clearances differ can be found in the
regional requirements section in OFTEC Book 3 2010
Pressure Jet
Location
Appliance Burner Type
Condensing
A
Directly below an opening, airbrick, opening window etc.
1000
B
Horizontally to an opening, airbrick, opening window etc.
1000
C
Below a gutter, eaves or balcony with protection
1000
D
Below a gutter or a balcony without protection
1000
E
From vertical sanitary pipe work
300
F
From an internal or external corner or surface or boundary alongside the terminal
300
G
Above ground or balcony level
300
H
From a surface or a boundary facing the terminal
2500
J
From a terminal facing the terminal
1200
K
Vertically from a terminal on the same wall
1500
L
Horizontally from a terminal on the same wall
750
M
Above the highest point of an intersection with the roof
600
N
From a vertical structure on the side of the terminal
750
O
Above a vertical structure less than 750mm from the side of the terminal
600
P
From a ridge terminal to a vertical structure on the roof
1500
Q
Above or to the side of any opening on a flat or sloping roof
300
R
Below any opening on a sloping roof
1000
Minimum distances to terminals in millimeters as measured from the top of the chimney
or the outer edge of where flue gases pass through low level discharge openings
SEE NEXT PAGE FOR IMPORTANT NOTES
Diagram 20a
Содержание Enviromax Kitchen C12
Страница 2: ......
Страница 27: ...6 25 6 7 INSTALLATION FLUE ASSEMBLY SLIMLINE SYSTEMPAC...