Range
Burner
Head
Fuel
Nozzle
P.P.
Air CO2
Fg.
Smoke
Type
Shutter Head
No.
50,000
Riello RDB 1.
T1
K
.5 80’H
7 Bar
2.4
-
11.5
190
0-1
60,000
Riello RDB 1.
T1
K
.5 80’H
10 Bar
3.9
-
11.5
200
0-1
70,000
Riello RDB 1.
T3
K
.6 80’H
8 Bar
4.25
-
11.5
210
0-1
70,000
Riello RDB 1.
T3
K
.6 80’H
8 Bar
4.25
-
11.5
190
0-1
80,000
Riello RDB 1.
T3
K
.6 80’H
9.5 Bar
4.8
-
11.5
195
0-1
90,000
Riello RDB 1.
T3
K
.75 80’S
8 Bar
6
-
11.5
210
0-1
90,000
Riello RDB 2.
T3
K
.75 80’S
8 Bar
6
-
11.5
190
0-1
110,000
Riello RDB 2.
T3
K
1.00 80’S
7 Bar
2.6
-
11.5
190
0-1
120,000
Riello RDB 2.
T3
K
1.00 80’S
9 Bar
3.5
-
11.5
190
0-1
Burner
Limit Stat
Control Stat
C.H. Pump
Room Stat Loop
D.H.W. Pump
Early Alert Stat
C.H. Timed Switch
D.H.W. Timed Switch
Relay Tank Stat.
Over Heat Stat.
Flow Switch
Timer Motor
Timer Motor
On
Off
Timed
E
L
N
12
14
22
24
32
34
1
6
11
11
21
31
4
3
5
7
8
9
2
10
A2
A1
Non Energised
Energised
Содержание Combi 120
Страница 10: ...2 TECHNICAL SPECIFICATION 9 2 E F Riello Burner Specification...
Страница 31: ...30...
Страница 32: ...Combi Oil Boiler PART 2 Sealed System Domestic Hot Water 31...
Страница 40: ...39 Combi Oil Boiler PART 3 Spare Parts...
Страница 41: ...9 FAULT FINDING 40 T Repair or Replace Oil Pump r No...
Страница 52: ...NOTES...