5
2
TECHNICAL SPECIFICATION
Pressure Jet Oil Burner
Riello RDB or Ecoflam Flair or Bentone Sterling
Fuel
Kerosene Class C2
Domestic Hot Water Plate
Heat Exchanger
Giannoni Albion,
SWEP or
Alfa Laval
Circulating Pumps
Grundfos UPS 25/60
Flue Pipe Connection
Conventional Flue Socket
To take tail piece for 4”
(100mm)
& 5”
(125mm)
S/S Flue Pipe
Balanced Flue Assembly
5”
(125mm)
Concentric Flue
Weight (Dry) - Incl. Pallet
50-70btu’s
- 160 Kg
70-90btu’s
- 162 Kg
90-120btu’s
- 177 Kg
Water Content - Total
50-70btu’s
- 59 Litres
70-90btu’s
- 59 Litres
90-120btu’s
- 68 Litres
- Primary Tank
50-70btu’s
- 40 Litres
70-90btu’s
- 40 Litres
90-120btu’s
- 44 Litres
Thermostats
Boiler Central heating Control
(Adjustable)
65˚C - 85˚C
Boiler Safety Limit
110˚C
Tank (DHW)-Fixed
78˚C
EA-Fixed
87˚C
Over-run-Fixed
93˚C
Boiler integral Expansion
Vessel nominal capacity
12 & 14 Litres pre-charged to 1 Bar
Heating System (Sealed)
Fit in accordance with BS 7074
Part I, BS 5449, OFTEC
Standards, etc.
Max. Operating Pressure
2.5 Bar
(Follow all BS & OFTEC Standards)
Max. System Pressure (Cold)
1.5 Bar
Min. System Pressure (Cold)
0.5 Bar + 0.3 Bar
Boiler Test Pressure
4.5 Bar
Safety Valve Operating Pressure 3 Bar
Heating System Pressure Gauge
(mains supply excepted)
0 - 6 Bar Range
Flue Draught Reqd.
(Conventional Flue)
Min: 0.040 In WG
Max: 0.15 ln WG
Water side resistance-10˚C Diff 26.8 ins WG
-20˚C Diff
8.6 ins WG
Mains Water Supply Pressure
Up to 10 Bar. (Fit pressure
reducing valve as necessary)
Mains Water Supply
Limescale excess - when
over 150/200 ppm
Consult Water Authority
Fit appropriate scale reducer
Also refer to Page 35
Domestic Hot Water Guide Performance
50-70,000 Btu’s - 120 Litres at 40˚
Δ
t at 12 Litres per minute
70-90,000 Btu’s - 120 Litres at 40˚
Δ
t at 14 Litres per minute
90-120,000 Btu’s - 120 Litres at 40˚
Δ
t at 18 Litres per minute
Содержание Combi 120
Страница 10: ...2 TECHNICAL SPECIFICATION 9 2 E F Riello Burner Specification...
Страница 31: ...30...
Страница 32: ...Combi Oil Boiler PART 2 Sealed System Domestic Hot Water 31...
Страница 40: ...39 Combi Oil Boiler PART 3 Spare Parts...
Страница 41: ...9 FAULT FINDING 40 T Repair or Replace Oil Pump r No...
Страница 52: ...NOTES...