21

TERMS & CONDITIONS OF WARRANTY

Firebird products are designed and manufactured to give
many years of trouble free service.

The terms laid down in the warranty must be adhered to

Firebird provides a comprehensive, conditional
warranty of 5 years on the boiler shell and 2 years on
all other parts from date of installation, provided
installation has occurred within 12 months from date
of purchase.

The 5 year boiler shell warranty consists of parts and
labour for the first 3 years and parts only for years 4 and
5.

The warranty will only apply if the boiler is
commissioned by an OFTEC registered or competent,
qualified engineer and is serviced annually thereafter.

Please ensure that the commissioning certificate
within the Boiler Passport is fully completed by an
OFTEC registered or competent, qualified engineer and
is returned to Firebird within 28 days of complete
installation and commissioning. The Boiler Passport is
included with every boiler and can also be completed
online at the following link:
http://www.firebird.ie/index.php/boiler-passport.html.

Correct commissioning will ensure that your boiler is
set to operate at its maximum fuel efficiency.

Consumable components, the nozzles and the oil hose
are excluded.

TERMS & CONDITIONS OF WARRANTY 

1.

Warranty implies that the product shall be free from
defective parts or workmanship for a period of
warranty cover, which begins from the date of
installation.

2.

All claims under the warranty programme must be
within the time limits stated on the left.

3.

Installation and commissioning of the product must
be in accordance with (a) instruction/technical
manuals (b) all relevant standards and codes of
practice.

4.

An OFTEC registered or competent, qualified
engineer, using the correct installation and test
equipment must carry out installation and
commissioning.

5.

This warranty does not cover special, incidental or
consequential damages, injury to persons or property,
or any other consequential loss.

6.

Maintenance should be carried out at the intervals
stated in the instruction/technical manual.

7.

Firebird accepts no liability in respect of any defect
arising from incorrect installation, negligence, fair
wear and tear, misuse, alteration or repair by
unqualified persons.

8.

Firebird will not accept any liability in respect of any
defect occurring to the product due to limescale
build-up and or low return water temperature.

9.

The warranty programme extends to reasonable
labour costs EXCEPT in the case of a 5 year warranty
period whereby any valid claim made after 3 years will
not include labour costs.

10. Firebird's prior authorisation must be obtained before

examination or repair of the product takes place.

11. Firebird will examine all claims made under the

warranty programme and for any claims that are
deemed invalid, the costs incurred will be borne by
the owner.

12. The warranty programme only applies where the

product was used for normal domestic heating
purposes.

13. Any defective part removed under any or all of the

warranty programmes MUST be returned to Firebird.

14. If this appliance is installed in a pressurised system,

failure to correctly size the expansion vessel may
damage the boiler and invalidate the warranty.

STATUTORY RIGHTS OF THE OWNER ARE NOT

AFFECTED BY THIS WARRANTY

9

Содержание BLUE FLAME ENVIROMAX

Страница 1: ...HEATING SOLUTIONS Working towards a greener planet This manual must remain with the householder once installation is complete BLUE FLAME ENVIROMAX CONDENSING BOILER TECHNICAL MANUAL...

Страница 2: ...Enviromax condensing oil boiler This instruction manual is produced for the reference and guidance of qualified installation engineers preferably OFTEC Oil Firing Technical Association registered EU l...

Страница 3: ...8 2012 A1 2014 EN 12831 2003 and the statutory requirements of the Building Regulations To ensure the highest standards of installation safety it is important that the boiler be installed in complianc...

Страница 4: ...attention should be sought following eye contact or prolonged reddening of the skin The small quantities of adhesives and sealants used in the product are cured They present no known hazards when used...

Страница 5: ...is factory fitted with a burner control box lockout safety feature which operates automatically if a fault occurs in the burner operation Should this occur the light on the top of the burner will illu...

Страница 6: ...ntrols to ensure return values are as stated above Magnetic Filtration It is recommended at the time of installation of this boiler to install a permanent effective magnetic filter on the return pipew...

Страница 7: ...service The condensate line should be plastic and have a minimum diameter of 22mm have a fall from the boiler of 1 100 minimum have as few bends as possible to reduce the risk of trapping condensate...

Страница 8: ...Out Inlet Out to drain Control panel Condensate Pump can be positioned within the casing of the boiler on the base or fixed to the casing of the boiler house boiler or mounted on the wall alongside t...

Страница 9: ...ECK FOR ANY BUILDING REGULATIONS AMENDMENTS WHICH MAY HAVE BEEN ISSUED AFTER THE PUBLICATION OF THIS MANUAL A A C B C A Horizontal from opening airbrick opening window etc B From an internal or extern...

Страница 10: ...or a balcony without protection 1000 E From vertical sanitary pipe work 300 F From an internal or external corner or surface or boundary alongside the terminal 300 G Above ground or balcony level 300...

Страница 11: ...been approved for low level flue and low level balanced flue discharge when tested to BS EN 303 1 5 Terminating positions must be at least 1 8m distant from an oil storage tank unless a wall with at l...

Страница 12: ...where air can pass freely across them to disperse vapours 3 The effect of the moisture generated must be considered in relation to the possible corrosion of metal parts it might reach and to the possi...

Страница 13: ...ipe system is required Ensure that valves and filters are not fitted in the return line as this must be unobstructed at all times The oil burner pump is set for two pipe operation as detailed in accom...

Страница 14: ...13 All tanks either deemed to be at risk or with a capacity of more than 2 500 litres will require to be bunded Those externally installed tanks with a capacity of less than 2 500 litres will require...

Страница 15: ...9 1 Condensate Hose 111537 10 1 1 2 Drain Valve 111329 11 1 Heat De ector 210904 12 1 MHG Rocket Burner 95201000840 13 1 Casing Top 214062 14 1 Casing Front 214061 15 1 Casing Door 214063 16 1 Casing...

Страница 16: ...1000840 12 1 Flue Kit 412031 13 1 1 2 Drain Valve 111329 14 1 Front Panel 211527 15 1 7 Pin Control Panel 310453 16 1 Back Panel 211547 17 1 Fixed Panel Right 213990 18 1 Removable Panel 212004 19 1 F...

Страница 17: ...rner 95201000840 12 1 Flue Kit 411982 13 1 Front Panel 211604 14 1 Control Panel 311146 15 1 Casing Right Side 214052 16 1 Casing Left Side 214051 17 1 Casing Top 214055 18 1 Back Panel 211605 19 1 Fl...

Страница 18: ...wiring in accordance with current ETCI IET Regulations and any local regulations which may apply 16 Permanent live from high limit stat Power to burner Temperture control dial max 80 C min 60 C High...

Страница 19: ...live Neutral Timed switch live Earth Permanent live Blue Flame Enviromax Heatpac Imit dual thermostat Pump over run thermostat 87 C Bi metal frost thermostat 5 C 14 C Please note a permanent live conn...

Страница 20: ...ure that the boiler is properly commissioned when first used The boiler should be commissioned by an OFTEC registered or competent qualified engineer familiar with Firebird products The installation c...

Страница 21: ...of the fuel The burner air setting should not be adjusted 6 If the CO reading is greater than 40ppm when commissioning this boiler contact the Firebird technical desk for assistance before leaving th...

Страница 22: ...n boiler passport Annual servicing must be carried out by an OFTEC registered or a competent qualified engineer familiar with Firebird products Do not commence service until both the electrical and oi...

Страница 23: ...commissioning of the product must be in accordance with a instruction technical manuals b all relevant standards and codes of practice 4 An OFTEC registered or competent qualified engineer using the...

Страница 24: ...ts please contact Firebird Heating Solutions Ltd dar s Industrial Estate Baile Mhic re Co Cork Ireland t 353 0 26 45253 f 353 0 26 45309 e info firebird ie web www firebird ie Firebird Heating Solutio...

Отзывы: