5
13
5.1 - TECHNICAL DETAILS - POPULAR
H
F
G
B
W
D
E
C
J
I
Front
Side
Top
A
Model
Blue Flame Enviromax
Output
kW
Weight
kg
Dimensions (mm)
H
W
D
A
B
C
E
F
G
I
J
Popular 26
26
125
740
470
425
300
113
177
100
176
502
355
126
No.
Qty
Description
C26
1
4
Tube Baffl
e 4 Way
110907
2
5
Tube Baffl
e Single
110908
3
4
Smoke Baffl
e
212028
4
1
Door Gasket
111314
5
1
Duroboard
110918
6
1
Flue Ring Gasket
112104
7
1
Stat Pocket
111317
8
1
Condensate Trap
112184
9
1
Condensate Hose
111537
10
1
1/2" Drain Valve
111329
11
1
Heat Defl ector
210904
12
1
MHG Rocket Burner
95201000840
13
1
Casing Top
214062
14
1
Casing Front
214061
15
1
Casing Door
214063
16
1
Casing Left Side
214058
17
1
Casing Right Side
214059
18
1
Casing Back
214060
12
5
4
3
1
2
7
6
11
9
10
8
14
15
17
18
13
16
All connections are 1” BSP
WATER CONTENT
Water Content Boiler - 24 Litres
WATER SIDE RESISTANCE
Flow rate to give a nominal
output at 10K differential
Flow Rate Measured 2135 kg/h
Waterside Resistance 0.18 mbar
Flow rate to give a nominal
output at 20K differential
Flow Rate Measured 1131 kg/h