background image

Contact us for assistance:  (866) 985-7877  |  www.wtliving.com 

      9

OPERATING INSTRUCTIONS

A minimum supply pressure of .5 psi is required for the purpose of input 

adjustment of propane gas. Storage of an appliance indoors is permissible  
only if the cylinder is disconnected and removed from the appliance. A cylinder 
must be stored outdoors in a well-ventilated area out of the reach of children. 
A disconnected cylinder must have dust caps tightly installed and must not 
be stored in a building, garage, or any other enclosed area. The minimum 

permissible gas supply pressure of 11 W.C. is required for purpose of hose 
adjustment. The minimum hourly of 17,500 BTU is required input rating for 

 

a heater for automatic operation rating less than full input rating.

The pressure regulator and hose assembly supplied with the appliance must 
be used.

The installation must conform with local codes, or in the absence of local codes, 
with national fuel gas code, ANSI Z223.1/NFPA54, natural gas and propane 
Installation Code, CSA B149.1, or propane storage and handling code, B149.2

A dented rusted or damaged propane cylinder may be hazardous and should 
be checked by your local cylinder supplier. Never use a propane cylinder 
with a damaged valve connection. The propane cylinder must be constructed 

and marked in accordance with the specifications for LPG tanks of the U.S. 

Department of Transportation (DOT) or the standard for cylinders, spheres and 
tubes for transportation of dangerous goods and commission, CAN/CSA-B339.

• The cylinder must have a listed overfilling prevention device.
• The cylinder must have a connection device compatible with the connection

for the appliance.

• The cylinder used must include a collar to protect the cylinder valve.
• Never connect an unregulated propane cylinder to the heater.

• Do not store a spare LP-gas

cylinder under or near this
appliance.

• Never fill the cylinder beyond

80 percent full.

• Place the dust cap on the

cylinder valve outlet whenever 
the cylinder is not in use. Only
install the type of dust cap
on the cylinder valve that is
provided with the cylinder
valve. Other types of caps or
plugs may result in leakage of
propane.

Содержание Lux Series

Страница 1: ...ng or servicing this equipment WARNING FOR OUTDOOR USE ONLY Comfort Quality Style Since 1998 Lux Series Patio Heater Item 63253 ATTACH YOUR RECEIPT Keep a copy of your proof of purchase or order confi...

Страница 2: ...and to educate new users of this appliance This manual should be read in conjunction with the labeling on the appliance Safety precautions are essential when any mechanical or propane fueled equipment...

Страница 3: ...o produce extremely minute non hazardous amounts of CO if used and maintained in accordance with all warnings and instructions Do not block the air flow into or out of the heater Carbon Monoxide CO po...

Страница 4: ...3 packed in 1 inner carton J Base withpre installedsandbox 1 Wheel Assembly 1 packed w Head Assembly Tank Strap secures cylinder 1 A C E F G H J HARDWARE CONTENTS B Reflector Panels Center Cap D I Bo...

Страница 5: ...Base Insert 1 Bolt AA through the hole in the support and into the Base then hand tighten Repeat with the other 2 Post Supports but leave hardware slightly loose until next step Hardware Used 3 x AA B...

Страница 6: ...d Assembly that MUST be removed prior to attaching Head Assembly to Post Route Gas Hose D down into Post and align 4 small holes on Head Assembly with 4 small holes in Post HINT Control knob should be...

Страница 7: ...old separately Use a standard 20 lb propane cylinder only Lift the Tank Housing C up and rest it on the top of the assembled Post Supports H Screw Regulator E onto the end of the Gas Hose D Do not cro...

Страница 8: ...and propane Installation Code CSA B149 1 or propane storage and handling code B149 2 A dented rusted or damaged propane cylinder may be hazardous and should be checked by your local cylinder supplier...

Страница 9: ...uctions WARNING Perform all leak tests outdoors Extinguish all open flames NEVER leak test when smoking Do not use heater until all connections have been leak tested and show no signs of leakage Befor...

Страница 10: ...knob clockwise toward the large flame symbol To decrease the flame turn the control knob counter clockwise towards the small flame symbol 6 To turn the appliance OFF push down the control knob and tur...

Страница 11: ...from the heater or placed on or near the heater m Any guard or other protective device removed for servicing the heater must be replaced prior to operating the heater m Installation and repair should...

Страница 12: ...or orifices This dangerous condition can damage heater and render it unsafe for use Clean burner holes by using a heavy duty pipe cleaner Compressed air may help clear away smaller particles Carbon d...

Страница 13: ...Gas pressure low with valve open full Replace cylinder or regulator AAA Battery behind igniter button is dead Replace with new AAA battery Cylinder valve on no gas flow Replace hose regulator assembl...

Страница 14: ...e of products covered by this limited warranty THERE ARE NO EXPRESS WARRANTIES EXCEPT AS LISTED PURCHASER ASSUMES ALL RISKS IN THE ASSEMBLY AND OPERATION OF THIS UNIT FAILURE TO FOLLOW WARNINGS AND OP...

Отзывы: