Fire Sense Bellante Скачать руководство пользователя страница 15

Contact us for assistance:  (866) 985-7877  |  www.wtliving.com 

      15

CONVERSION TO NATURAL GAS

   

WARNING! 

The installation must be performed by a licensed gas fitter, and all connections must be

leak tested before operating the appliance.

Ensure all hose connections are tightened using two wrenches. Do not use Teflon tape or

pipe dope on any hose connection.

Ensure the hose does not contact any high temperature surfaces or it may melt and leak
causing a fire.

Locate the hose away from pathways where people may trip over it and areas where the

hose may be subject to accidental damage.

Leak test all the connections using a soap and water solution as per the leak testing

instructions found in the manual.

Natural Gas Hook-Up

The gas appliance is designed to operate at an inlet pressure of 7 inches water column. The piping up to the appliance is the 
responsibility of the installer. Connect the inlet valve to rigid pipe, copper tube or an approved flexible metal connector, 
which complies with Z21.4/CSA 6.10. If using a gas hose (not supplied) connect the flanged end of the hose to the connector 
on the end of the inlet valve. Tighten using two wrenches. (Do not use thread sealer/pipe dope.) Leak test all joints prior to 
using the appliance. Piping and valves upstream of the quick disconnect are not supplied. The gas supply pipe must be 
appropriately sized to supply the BTU/hr specified on the rating plate, based on the length of the piping run. The quick 
disconnect must not be installed in an upward direction and a readily accessible manual shut-off valve must be installed 
upstream of, and as close to, the quick disconnect as is feasible.

Purge the gas supply line of any trapped air prior to the first firing of the unit.

Содержание Bellante

Страница 1: ...jury or property damage 2 Read the installation operation and maintenance instructions thoroughly before installing or servicing this equipment 3 Failure to follow these instructions could result in f...

Страница 2: ......

Страница 3: ...12 for assy 1 extra Bolt 6x20mm Qty 8 7 for assy 1 extra Washer M6 Qty 20 19 for assy 1 extra Spring Washer M6 Qty 13 12 for assy 1 extra Hex Key Wrench Screwdriver Nut 6mm Qty 13 12 for assy 1 extra...

Страница 4: ...property loss or damage from hazards of fire explosion burn asphyxiation and or carbon monoxide poisoning Only persons who can understand and follow the instructions should use or service this fire pi...

Страница 5: ...de down and align the holes in the top of the Legs with the Studs in the Table Top Place the holes over the Studs and secure each with Washer Spring Washer Nut N as illustrated Tighten with Wrench V T...

Страница 6: ...en with Hex Key W Attach Tank Support Bar I to Door Frame Leg F and Support Leg 1 G by aligning holes at each end of Tank Support Bar with holes at the bottom of Door Frame Leg and Support Leg 1 Place...

Страница 7: ...y on the top of the fire pit which can cause bending or warping When all panels and the tank support have been secured turn the table upright Place the Burner B into the hole in the Table Top rotated...

Страница 8: ...entilated area out of the reach of children A disconnected cylinder must have dust caps tightly installed and must not be stored in a building garage or any other enclosed area The maximum inlet gas s...

Страница 9: ...ention device The cylinder used must include a collar to protect the cylinder valve Never connect an unregulated propane cylinder to the fire pit Attach regulator to cylinder Complete attachment Insta...

Страница 10: ...leak test If bubbles continue appearing the hose should be returned to the place of purchase 3 If leak is at regulatory cylinder valve connection disconnect reconnect and perform another leak test If...

Страница 11: ...fastened prior to starting m I understand children and adults should be alerted to the hazard of high surface temperatures and should stay away to avoid burns or clothing ignition m I understand youn...

Страница 12: ...DO NOT try to repair it Call a qualified professional service technician Force or attempted repair may result in fire or explosion and will void the warranty 1 Turn the control knob to OFF position F...

Страница 13: ...ire valve system The process of converting the burner from Propane to Natural Gas is relatively simple and can be accomplished by any handy homeowner We recommend however that a qualified gas technici...

Страница 14: ...less steel Flex Line from the brass Connector Valve using two Wrenches 3 Unscrew the Connector Valve from the Burner Pipe 4 Slide the Air Shutter tube included in the conversion kit onto the Burner Pi...

Страница 15: ...let pressure of 7 inches water column The piping up to the appliance is the responsibility of the installer Connect the inlet valve to rigid pipe copper tube or an approved flexible metal connector wh...

Страница 16: ...ven Fire pit makes popping noise Spiders and insects can nest in burner or orifices This dangerous condition can damage fire pit and render it unsafe for use Clean burner holes by using a heavy duty p...

Страница 17: ...ckage Control knob is not in ON position Turn control knob to ON Burner flame is low Gas pressure is low Turn cylinder valve OFF and replace cylinder Outdoor temperature is less than 40 F and tank is...

Страница 18: ...ANTIES EXCEPT AS LISTED PURCHASER ASSUMES ALL RISKS IN THE ASSEMBLY AND OPERATION OF THIS UNIT FAILURE TO FOLLOW WARNINGS AND OPERATION AL INSTRUCTIONS CONTAINED IN THIS MANUAL CAN RESULT IN SEVERE PR...

Отзывы: