background image

Version: August 2020                                                                       

                    

 

 

 

 

Firebox Lining Removal Process (if required) 

 

  In order to install the GD6 Exposed Burner, 

the base firebox lining must be removed

 to gain access to the 

base fixing brackets. 

  In some circumstances (eg. the need to reduce overall weight so the appliance can be lifted up stairs), it may 

be necessary to remove (then replace) the firebox lining.  

 

 

  The GD6 has three firebox lining options: Dark tile, Steel, and Client-supplied.  

 

  Particular care should be taken when removing and replacing the chosen Fire lining into the appliance. 

Failure to place the firebox lining correctly may result in the appliance performing inefficiently.

 

 

 
 

Dark

 

tile

 

lining (supplied

 as default option):

 

 
Black slate  – 9mm. 

 
Size – 600mm x 600mm cut to suit. 

 
Finish – Dark slate. 

 
 
 
 

Steel

 

lining

 

Mild steel  – 2mm. 

 
Size – Cut and folded to suit appliance. 

 
Finish  – Matt black paint. 

 
 
 

 

 
Client-supplied

 

lining:

 

Requirements 

 
Non-combustible and heat resistant. 

 
Size – Maximum thickness 10mm. 
 

Size – Minimum height for tiles 500mm.   

All measurements must be confirmed on site. 

 
Finish – Robust and self-supporting. 

 

                                                                                                      

 

Example of a client-supplied fire box lining

 

 
 
 

 
 
 
 
 
 
 
 
 
 

Содержание GD6 Series

Страница 1: ...GD6 Exposed Burner Wall Switch Installation Guide Operating Instructions Warranty...

Страница 2: ...the steel surrounding become extremely hot during operation and can result in serious injury and burns if touched It is therefore recommended that a fireguard complying with BS 8423 2002 is used in t...

Страница 3: ...exception to these minimum clearances is the base and the front surround panels of the appliance the base can safely sit directly upon combustible e g timber and non combustible e g concrete material...

Страница 4: ...burner tubes GD6 EB 1600 Input 65 70 MJ h One gas injector on the front burner tube and one gas injector on each of the two rear burner tubes A Remove the side panels 2 x screws at each end of the ex...

Страница 5: ...rear burner tubes GD6 EB 1600 Input 65 70 MJ h One gas injector on the front burner tube and one gas injector on each of the two rear burner tubes Fit the front cover under the exposed burner Replace...

Страница 6: ...the weather housing must be a minimum of 1 0mm 4 core cable ensure 1000mm of cable is at the centre of the cavity as this is where it will connect to the GD6 burner Disconnect the electrical cable to...

Страница 7: ...are should be taken when removing and replacing the chosen Fire lining into the appliance Failure to place the firebox lining correctly may result in the appliance performing inef ciently Dark tile li...

Страница 8: ...sed Burner Removal Process in this guide 2 Remove the top three lining fixing brackets 5mm cap screws 3 Allow the top of the lining to fall forward 4 Carefully lift the lining up and out of the base c...

Страница 9: ...load In order to provide maximum positioning flexibility the base of the appliance has two fixing brackets with two 30mm long slots in each The two xing brackets will clamp the appliance into position...

Страница 10: ...the electrical connections between the appliance and the switch can be seen use 4 core minimum 1mm cable Following these connection details using the 4 core cable that has been run at site connect the...

Страница 11: ...Version August 2020 11 Fan for GD6 1400 1600...

Страница 12: ...ed Connect 3 8 soft copper pipe to main valve Leak test all joints Switch the appliance ON Test adjust high pressure first using the outer brass nut and then the low pressures against rating plate spe...

Страница 13: ...chosen firebed medium onto the burner Failure to place the medium correctly may result in the appliance performing inefficiently Open the firebed cardboard box and identify firebox mediums GD6 EB 1200...

Страница 14: ...k natural and non uniform running the entire length of the burner Common flame effect issues are Flames burning under logs Missing flames along length of burner Both these issues can be resolved by sw...

Страница 15: ...tural and non uniform running the entire length of the burner Common flame effect issues are Flames burning under logs Missing flames along length of burner Both these issues can be resolved by switch...

Страница 16: ...appliance Following the GD6 Exposed Burner Operating Instructions on the next page show the owner how to switch the appliance ON and OFF and how to switch between HIGH and LOW settings If the owner is...

Страница 17: ...nal from flame rectifier interrupted 5 Signal to sparker electrode interrupted 6 Incorrect sparker electrode gap 1 Check gas supply 2 Check power supply 3 Check flame size and pressure 4 Check flame r...

Страница 18: ...d warping if a firebox outer skin or support frame defect occurs contact The Fire Dept and the defect will be repaired or replaced at our discretion with all costs covered The Fire Dept warrants the S...

Отзывы: