Firebox Lining Removal Process (if required)
•
In order to install the GD6 Exposed Burner,
the base firebox lining must be removed
to gain access to the
base fixing brackets.
•
In some circumstances (eg. the need to reduce overall weight so the appliance can be lifted up stairs), it may
be necessary to remove (then replace) the firebox lining.
•
The GD6 has three firebox lining options: Dark tile, Steel, and Client-supplied.
•
Particular care should be taken when removing and replacing the chosen Fire lining into the appliance.
Failure to place the firebox lining correctly may result in the appliance performing inefficiently.
Dark
tile
lining (supplied
as default option):
Black slate – 9mm.
Size – 600mm x 600mm cut to suit.
Finish – Dark slate.
Steel
lining
:
Mild steel – 2mm.
Size – Cut and folded to suit appliance.
Finish – Matt black paint.
Client-supplied
lining:
Requirements
Non-combustible and heat resistant.
Size – Maximum thickness 10mm.
Size – Minimum height for tiles 500mm.
All measurements must be confirmed on site.
Finish – Robust and self-supporting.
Example of a client-supplied fire box lining