To immediately arm the system enter 

[USER] 

after the last zone

bypass.

FORCED ARMING

Forced Arming is a method that will automatically bypass all

zones that are not ready and ARM the system.

 

FORCED ARMING PROCEDURE;

BYPASS [USER] BYPASS

Depress the BYPASS key followed by your user code and the

BYPASS key.

If any of the zones currently faulted are not bypassable, then

the command will not succeed, and a long interrupted beep will
follow.

Following a sucessful forced arming the ARMED indicator will

be lit.

If you are leaving the premise, you may exit through an

exit/entry door for the duration known as the exit entry delay.

>>

Note: You have just ARMED the system and the bypassed
portions of your system re main unprotected.

UNBYPASS

The UNBYPASS function removes an existing bypass from a

currently bypassed zone. After UNBYPASSING a zone, the bypass

indication will be removed from that zone.

 

The procedure is similar to a bypass.

UNBYPASS PROCEDURE

11

DISARMING

Disarming the security system will deactivate the burglary

 

portions of the system.

DISARM PROCEDURE:

[USER]

Enter your user code.

IF NO ALARMS HAVE TAKEN PLACE

Upon disarming the ARMING indicator will go off.

The system display will reflect the current status.

IF ALARMS HAVE TAKEN PLACE

If alarms or other conditions such as system troubles have

taken place since the initial system arming, they will appear on the
display. The conditions that have occurred appear in the zone
display section of the keypad. Each indicator light reflects the

status of each zone as follows;

ALARM 

             

 Fast blinking

TROUBLE 

         

  Slow pulse

BY PASS
NOT READY

         

Slow low lntenslty blinking
Solid ON

If an intrusion has taken place while you were away, do not enter

until the premisis has been secured!!!.

>>

To clear the display of the alarm or trouble conditions and

silence the audible signal enter [USER] again.

BYPASS [USER] ZN See bypass description.

12

Содержание LEGEND series

Страница 1: ......

Страница 2: ... is important that you feel comfortable with its operation The following pages will familiarize you with the procedures for operating the LEGEND Security System Thank You FIRE BURGLARY INSTRUMENTS LEGEND Users Manual Table of Contents Introduction 1 Keypad Layout 3 System Operation 6 Arming 7 Stay 8 Instant 9 Instant Stay 9 Bypass 10 Forced Arming 11 Unbypass 11 Disarming 12 Keypad Emergency Condi...

Страница 3: ...e system is low 3 STAY The STAY light will be ON when the system has been armed in the stay mode which means that the system has been activated with the exception of interior zones 4 READY INDICATOR The light marked RDY shows whether the system is ready fo be armed If the light is off then a condition exists within at least one of the zones which prevents the system from being armed 5 COMMUNICATIO...

Страница 4: ...terior zones The BYPASS key will be used to temporarily turn off protection of a portion of your burglary protection This could be performed for example to ignore an open window which would prevent the arming of your system 13 INSTANT Key The INSTANT key is used to activate arm the system and eliminates the entry delay This would cause an immediate alarm if someone came through an exit entry zone ...

Страница 5: ... ON This means zone 3 is not ready Typically this might mean that a protected door or window is open 7 Once the problems with each zone has been resolved the READY light will appear and the system can be armed To arm the system in this situation one of the following actions are necessary Make the zone s ready Determine which zones are not ready and perform what is necessary to ready the zone s exa...

Страница 6: ...ions bypassed and the entry delay will be suspended The system must be READY in order to enter this mode PROCEDURE INSTANT STAY USER STAY INSTANT USER Depress the INSTANT and STAY keys in any order followed by your user code After a sucessful INSTANT STAY arming the ARMED INSTANT 9 and STAY indicators will be lit Multiple zones may be bypassed by repeating the sequence for the desired number of zo...

Страница 7: ...e the bypass indication will be removed from that zone The procedure is similar to a bypass UNBYPASS PROCEDURE 11 DISARMING Disarming the security system will deactivate the burglary portions of the system DISARM PROCEDURE USER Enter your user code IF NO ALARMS HAVE TAKEN PLACE Upon disarming the ARMING indicator will go off The system display will reflect the current status IF ALARMS HAVE TAKEN P...

Страница 8: ...keys at the same time The RESET 3 1 command can be used to acknowledge conditions such as alarms and troubles at the keypad if the reset 13 function has been enabled by your installer The DURESS signal is meant to disarm the system and transmit an emergency signal to the Central Station indicating that there is a problem The DURESS capability must be enabled by your installer and can be initiated ...

Страница 9: ... separate user must be assigned a unique user code The user ID has been displayed as USER throughout this manual AUTHORIZATION LEVEL The LEGEND control panel contains authorization levels to control the users permitted to perform various system functions This allows users to be restricted to certain functions The levels are shown below LEVEL1 ARM DISARM BYPASS PROGRAM USERS LEVEL2 ARM DISARM BYPAS...

Отзывы: