Fire Burglary Instruments LEGEND series Скачать руководство пользователя страница 5

ARMING THE SYSTEM

ARMING the system will activate all portions of your Security

System. Arming can only be performed if all zones are READY. For
example, if a protected door is open the system cannot be armed.  

SYSTEM READY

The system is ready to be armed if the READY indicator light

located in the display portion of the keypad is ON. If the system is
ready, ARMING can be performed as follows;

ARMING PROCEDURE

1. Enter your four digit user code into the keypad:

[USER]

The ARMED indicator light will now be lit and if you are leaving

the home you may exit through a door designated by your installer

as an exit/entry zone for a fixed time period known as the exit delay.

SYSTEM NOT READY

If the system is not ready to be armed the READY indicator will

be OFF. The zone indicator lights will display the zones which are
currently not ready. The condition of each zone indicator reflects

what the status of each zone as follows;

ALARM

        

Fast blinking

BYPASS                     Slow blinking

TROUBLE                   Slow pulse

NOT READY

      

 

Solid ON

low intensity.

In order to make the system ready ready determine which zones

are not ready by observing the zone indicator lights. From the zone
number you can find out which area of protection is not ready.

For example, assume the the zone 3 indicator light is ON. This

means zone 3 is not ready. Typically this might mean that a
protected door or window is open.

>>

7

Once the problems with each zone has been resolved the

READY light will appear and the system can be armed.

To arm the system in this situation one of the following actions

are necessary;

-

 Make the zone(s) ready. Determine which zones are not ready

and perform what is necessary to ready the zone(s) (example,
close the door or window, etc),

or

-

 Bypass the zone(s) not ready. Bypassing should only be

performed if the zone cannot be made ready or intentionally will
remain not ready. Remember, zones that are bypassed are 

not

protected when the system is armed.

STAY  

The STAY mode is another way to ARM your system while you

remain in the location. The STAY mode will deactivate any interior
protection zones which means that you will be free to walk

throughout your location without activating the alarm system.

In order to enter the STAY mode, the system must be READY.

(see previous description).

STAY PROCEDURE:

STAY [USER]

Depress the STAY key followed by your user code.

After a sucessful STAY arming the ARMED and STAY indicator

will be lit. In the STAY mode only the external or perimeter burglary

protection is active. You are free to walk around the residence

without activating any of the interior protection zones.

>>

Remember, you must DISARM the system to when you 

want

to leave the premise.

Note: The STAY

system is disarmed.

 

option will automatically be reset after the

8

Содержание LEGEND series

Страница 1: ......

Страница 2: ... is important that you feel comfortable with its operation The following pages will familiarize you with the procedures for operating the LEGEND Security System Thank You FIRE BURGLARY INSTRUMENTS LEGEND Users Manual Table of Contents Introduction 1 Keypad Layout 3 System Operation 6 Arming 7 Stay 8 Instant 9 Instant Stay 9 Bypass 10 Forced Arming 11 Unbypass 11 Disarming 12 Keypad Emergency Condi...

Страница 3: ...e system is low 3 STAY The STAY light will be ON when the system has been armed in the stay mode which means that the system has been activated with the exception of interior zones 4 READY INDICATOR The light marked RDY shows whether the system is ready fo be armed If the light is off then a condition exists within at least one of the zones which prevents the system from being armed 5 COMMUNICATIO...

Страница 4: ...terior zones The BYPASS key will be used to temporarily turn off protection of a portion of your burglary protection This could be performed for example to ignore an open window which would prevent the arming of your system 13 INSTANT Key The INSTANT key is used to activate arm the system and eliminates the entry delay This would cause an immediate alarm if someone came through an exit entry zone ...

Страница 5: ... ON This means zone 3 is not ready Typically this might mean that a protected door or window is open 7 Once the problems with each zone has been resolved the READY light will appear and the system can be armed To arm the system in this situation one of the following actions are necessary Make the zone s ready Determine which zones are not ready and perform what is necessary to ready the zone s exa...

Страница 6: ...ions bypassed and the entry delay will be suspended The system must be READY in order to enter this mode PROCEDURE INSTANT STAY USER STAY INSTANT USER Depress the INSTANT and STAY keys in any order followed by your user code After a sucessful INSTANT STAY arming the ARMED INSTANT 9 and STAY indicators will be lit Multiple zones may be bypassed by repeating the sequence for the desired number of zo...

Страница 7: ...e the bypass indication will be removed from that zone The procedure is similar to a bypass UNBYPASS PROCEDURE 11 DISARMING Disarming the security system will deactivate the burglary portions of the system DISARM PROCEDURE USER Enter your user code IF NO ALARMS HAVE TAKEN PLACE Upon disarming the ARMING indicator will go off The system display will reflect the current status IF ALARMS HAVE TAKEN P...

Страница 8: ...keys at the same time The RESET 3 1 command can be used to acknowledge conditions such as alarms and troubles at the keypad if the reset 13 function has been enabled by your installer The DURESS signal is meant to disarm the system and transmit an emergency signal to the Central Station indicating that there is a problem The DURESS capability must be enabled by your installer and can be initiated ...

Страница 9: ... separate user must be assigned a unique user code The user ID has been displayed as USER throughout this manual AUTHORIZATION LEVEL The LEGEND control panel contains authorization levels to control the users permitted to perform various system functions This allows users to be restricted to certain functions The levels are shown below LEVEL1 ARM DISARM BYPASS PROGRAM USERS LEVEL2 ARM DISARM BYPAS...

Отзывы: