background image

THIS MANUAL CONTAINS VITAL INFORMATION FOR THE SAFE USE AND EFFICIENT

OPERATION OF THIS MACHINE. CAREFULLY READ THIS OPERATOR’S MANUAL BEFORE

STARTING THE MACHINE, AND RETAIN FOR FUTURE REFERENCE. INSTRUCT ALL

OPERATORS TO READ THIS MANUAL. FAILURE TO ADHERE TO THE INSTRUCTIONS

COULD RESULT IN SERIOUS BODILY ANJURI OR PROPERTY DAMAGE.

PRESCRIBED USAGE

This machine is designed for the professional cleaning according to these operating instructions.

For the safe operation of this machine, and for the safety of the operator observe the following in-

structions:

1) Do not use this machine in an explosive atmosphere such as gas vapor etc. .

2) Do not operate this machine unless it is completely assembled.

3) Do not leave this machine plugged into the power source while unattended.

4) The Floor Maintainer is designed to be used with detergent and water .They should never be

used with flammable materials such as : gasoline, kerosene, etc. .

5) Do not clean this machine with a high pressure cleaner by water but use only air pressure
cleaner.

GENERAL SAFETY INSTRUCTION

This machine is designed and constructed according to the present state of the art and recogni-

sed technical safety standards. It is fitted with protective devices, following safety European

standard rules. Dangers can occur in spite of this, in particular in the case of maloperation or

non-compliance with the specifications and information in the operating instructions.
All our equipements are covered by international assurances against risks.

1) Sources of danger.

Electrical voltage / Electric current

Warning: Danger

Contact with voltage or current carryng parts carries the risk of electric shock which can result in

serious injury or even death. Never touch damaged cables. Always switch off and disconnect the

power supply before carrying out any work on the machine. Replace faulty cables immediately.

2) Improper usage.

Any usage of the machine for a purpose not covered under the “Prescribed usage” or contrac-
tually agreed purpose is not permissible. The use of the machine in an unserviceable condiction

or not in compliance with the following prescription is prohibited:

- Protective devices must not be removed or bypassed.

- Conversions and modification to the machine are not permitted.

- Defective supply cables are only to be replaced by original FIORENTINI cables.
- Coupling elements between mains supply or detachable extension cable must be at least

splashproof.

- The machine is to be fitted with a type H circuit breaker for rated current of 15A.

3) Organisational points.

It is the responsibility of the operator to ensure that:

- The machine is used only by personnel who have been instructed in its handling and authori-

sed to use it.

- The recognised occupational safety regulations are observed.

- Any further national or internal company regulations are observed.

- All users are acquainted with the safety regulations and trained in the use of the specific machi-
ne.

- All users have read and understood the operatin instructions.

- Responsabilities for the operation, maintenance and repair of the machine are clearly assigned

and observed.

- Faults and damage are immediately notified to the Service Agent of FIORENTINI.

4) Emergencies.

In the case of an emergency:

- Pull out the mains connector plug.

- Immediately apply recognised first-aid measures.

After incidents, do not resume operation with the machine until it has been inspected by FIOREN-

TINI authorized technical.

5) Operating for the first time.

Содержание HS 2000

Страница 1: ...ING O FIORENTINI s r l HS 2000 Spare parts Operating instructions and maintenance ...

Страница 2: ......

Страница 3: ...arries the risk of electric shock which can result in serious injury or even death Never touch damaged cables Always switch off and disconnect the power supply before carrying out any work on the machine Replace faulty cables immediately 2 Improper usage Any usage of the machine for a purpose not covered under the Prescribed usage or contrac tually agreed purpose is not permissible The use of the ...

Страница 4: ... a front caster to stabilize the machine at its 2000 rpm operating speed This caster is adjustable to achieve proper pad pressure Pleas refer to the pad installation procedures regarding adjustement of this caster The machine was pre adjusted at the factory using a 25mm thick pad Fiorentini high speed floor machines come equipped with a 15m heavy gauge power cord We do not recommend the use of ext...

Страница 5: ...peration DO NOT OVERLOAD THE MOTOR BY SETTING THE PAD TOO LOW Make only minor adjustments and make a test pass with the machine Compare the sheen after each pass When the adjustment is completed retighten the lock nut against the bracket to hold the pad height at the selected level MAINTENANCE OF MACHINE WARNING MAINTENANCE SHOULD BE PERFORMED BY QUALIFIED PERSONNEL ONLY Your Fiorentini standard s...

Страница 6: ...off 8 Remove three 3 screws holding the pad driver in place and lift off 9 Remove drive belt and inspect pulleys for damage Remplace if necessary 10 Install new belt into grooves on pulleys 11 Turn bolt in L bracket cloclwise to tighten the new belt Tighten until there is no play in the belt and stop DO NOT OVERTIGHTEN THE BELT 12 Tighten the bolts holding the motor in place Replace the protection...

Страница 7: ... new brushes 7 Reconnect brush leads and tighten brass retaining screws 8 Reinstall drip cover and connect power lead 9 Return handle to full upright position and lock 10 Reconnect power cable to outlet plug in machine and test the machine 1 Motor brush 2 Brushes with TECNICAL CHARACTERISTICS POWER 1100 W PROTECTION CLASS 1 LENGTH OF CORDS 15 m BRUSH SIZE 480 mm BRUSH REVS 2000 rpm ENERGY SOURCE d...

Страница 8: ......

Страница 9: ...200 01 042 CH004 1 LINGUETTA 4 8x38 TONGUE 4 8x38 CLAVETTE PASSFEDER 200 01 043 VE244 4 VITE ESAGONALE M6x20 UNI 5737 77 SCREW VIS SCHRAUBE 200 01 044 TP072 1 TELAIO BASE MONOSPAZZOLA HS 2000 FRAME CHASSIS MASCHINELLE 200 01 045 CA054 1 CARTER PROTEZIONE DISCO SPAZZOLA COVER COUVERCLE DECKEL 200 01 046 AL037 1 ALBERO ROTAZIONE DISCO SPAZZOLA SHAFT ARBRE WELLE 200 01 047 SG060 2 ANELLO SEEGER PER I...

Страница 10: ......

Страница 11: ...GGIO SPESSORATO FLANGE FLASQUE FLANSCH 200 01 093 DD256 2 DADO AUTOBLOCCANTE M12 SELF LOCKING NUT ECROU DE SURETE MUTTER 200 01 094 DD256 2 DADO AUTOBLOCCANTE M12 SELF LOCKING NUT ECROU DE SURETE MUTTER 200 01 095 RO206 2 RONDELLA NORMALE DIAM 12 UNI 6592 69 WASHER RONDELLE SCHEIBE 200 01 096 VE305 2 VITE ESAGONALE M12x55 UNI 5737 77 SCREW VIS SCHRAUBE 200 01 097 RO206 2 RONDELLA NORMALE DIAM 12 U...

Страница 12: ......

Страница 13: ... 200 02 003 PY307 1 SPINETTA MASCHIO 250V 10A PLUG CONNECTEUR STECKER 200 02 004 IN024 1 MICRO COMANDO ROTAZIONE SPAZZOLA BRUSH ROT MICRO CONTR MICRO INTERRUPTEUR MIKROSCHALTER 200 02 006 IN025 1 MICRO SICUREZZA AH71865 MICRO SAFETY MICRO SURETE MIKROSCHALTER 200 02 007 MP138 4 CARBONCINO MOTORE MONOSP HS BRUSH MOTOR CHARBONS MOTEUR MOTORBURSTE 200 02 008 MO130 1 MOTORE MONOSP HS 1 5 HP 3200 RPM M...

Страница 14: ......

Страница 15: ......

Страница 16: ...FIORENTINI s r l The Best in floor machines FILIALI 20132 MILANO Fax 02 2592779 Via Palmanova 211 a Tel02 27207783 2564810 00155 ROMA Fax 06 22754075 Via Carlo Carrà 13 Tel 06 22754040 2275060 STABILIMENTO 50030 PIANCALDOLI FI Fax 055 817144 Loc Rombola Tel 055 817092 817093 Distribuito da ...

Отзывы: