9.1 Main technical index
PCB h
ld
t th f ll
i
i
t
9. Description of software operation
PCB should meet the following requirements:
• Measured from the receiver
ˈ
receiving distance of remote control should
8m
ˈ
receiving
angle
60
e
cone angle
˗
• Discrepancy of temperature control
f
1
ć˗
• Discrepancy of time control
5min/24h
˗
• Discrepancy of indoor PG fan speed
˖f
10rpm
˗
R
d
l
AC230
f
20%
0H
• Rated power supply
˖
AC230
f
20%
ˈ̚
50Hz
˗
• PCB should conform to RoHS.
9.2 Definition
• RT
˖
room temperature.
• IPT
˖
indoor coil temperature.
• ST
˖
setting temperature
ˈ
range 18
̚
30
ć
• OPT
˖
outdoor coil temperature.
• NTC data
˖
R25=5.0K
ȍ
f
1% B25/50=3470
f
1%
9.3 Mode introduction
9 3 1 Auto mode
9.3.1 Auto mode
After running the unit by ON/OFF key or choose the auto running mode by remote control, it will fix its
running mode by judging room temperature (see below table):
Indoor temp.
Indoor temp.
20
ć
20
ć˘
indoor
˘
25
ć
indoor
25
ć
Running mode
heating
fan
cooling
St d d fi d
20
ć
22
ć
25
ć
Standard fixed
setting temperature
20
ć
22
ć
25
ć
Note:
1.
When Auto mode is selected, unit would check room temperature first and work with fixed mode as
above accordingly. Every 6 minutes, unit would check room temperature again, running mode would
be changed according with update room temperature.
2
If working mode is changed by remote control unit has 3 minutes delay protection for compressor
2.
If working mode is changed by remote control, unit has 3 minutes delay protection for compressor.
3.
Fan speed selection: For Dry mode, fan speed is fixed with low speed. For Cooling, Heating and Fan
mode, fan would work with set speed.
4.
Unit has protection function, including 3 minutes delay function, Anti-cold function before heating,
Over heating protection during heating function, Anti-frozen during cooling mode, E1,E2,E3,E4
protection.
Содержание iCOOL
Страница 4: ...3 Overall Dimensions Note The external pipes are same Ø197mm ...
Страница 5: ...4 Explosion view and parts list 4 1 iCOOL Explosion view ...
Страница 8: ...4 2 iWARM Explosion view ...
Страница 12: ......
Страница 13: ...7 Installation ...
Страница 14: ......
Страница 15: ......
Страница 19: ...8 ICOOL IWARM Electric wiring ...
Страница 28: ...R25 5 0K 1 7HPSe 5HVLVWDQFH YDOXH 7HPSe 5HVLVWDQFH YDOXH 7HPSe 5HVLVWDQFH YDOXH 7HPSe 5HVLVWDQFH YDOXH 23 7103 ...