Drainage hole (P8)
This air conditioner has a system to drain the condensate moisture automatically. Please read
carefully the following instruction.
Drill a hole through the wall measuring 30mm in diameter in the position shown in the paper template,
Drill a hole through the wall measuring 30mm in diameter in the position shown in the paper template,
marked the center before. Drainage occurs by gravity. For this reason, it is essential for the drain line
to have a minimum downward inclination at least 3 degrees throughout its length. With this solution,
you can drain the condensate moisture to a suitable place to do not cause any problems to your
neighbours.
This drainage method is more common use, and the discharge pipe goes outside where there is no
problem to connect or to discharge it, this solution is OK for hot country and normal cold temperature
outside.
W ll b
k t h l
(P9)
Wall bracket holes (P9)
Drill the holes for anchoring the unit to the wall using preferably the 2 holes with 10mm diameter
showed in black on the paper template. As the unit is installed on high wall, it is recommended that the
bolts should be fixed very well.
7.4 Fastening the anchors (P10)
Insert the concrete anchors into the holes for the unit and tighten them inside the wall
Insert the concrete anchors into the holes for the unit, and tighten them inside the wall.
The anchor bolts provided require 10mm holes; the wall should be inspected to determine if provided
bolts are useful or if it is necessary to use a different anchorage. The manufacture is not liable in case
of underestimation of the structural consistency of the anchorage made at the time of installation.
7.5 Fitting the gratings
After drilling the holes, the plastic gratings supplied with air conditioner need to be fitted on the wall.
1.When gratings is easy accessibility, you could fix the gratings from outside, it is recommended to
fasten it to the wall with wall plugs and screws with a diameter of 6mm, and keep the fins in vertical
position. (See image P11 )
2. When the air conditioner is installed in the high space, and impossible to reach the gratings from
outdoor side, you could fix the gratings from inside.
Put the silicon gel around of the soft grating, like Fig17.Then fold the outer grating in half, insert your
arm inside the hole with the grating. Let the grating unfold and pull the grating toward you. With a little
i
d
i l i
h 2
i
ill fi h
d f h h l
(P12 13 14)
patience and manipulation, the 2 gratings will fit the end of the holes. (P12,13,14)
After fixing the outside grating,we could inject more gel inside the space between the grating and wall.
(See P15,16)
The black silicon gel is just for reference, we could use white or transparent color gel to fix the outdoor
grille.(P17)
The above installation solution is just for solid wall.
Содержание iCOOL
Страница 4: ...3 Overall Dimensions Note The external pipes are same Ø197mm ...
Страница 5: ...4 Explosion view and parts list 4 1 iCOOL Explosion view ...
Страница 8: ...4 2 iWARM Explosion view ...
Страница 12: ......
Страница 13: ...7 Installation ...
Страница 14: ......
Страница 15: ......
Страница 19: ...8 ICOOL IWARM Electric wiring ...
Страница 28: ...R25 5 0K 1 7HPSe 5HVLVWDQFH YDOXH 7HPSe 5HVLVWDQFH YDOXH 7HPSe 5HVLVWDQFH YDOXH 7HPSe 5HVLVWDQFH YDOXH 23 7103 ...