Drainage hole (P8)

This air conditioner has a system to drain the condensate moisture automatically. Please read 
carefully the following instruction.

Drill a hole through the wall measuring 30mm in diameter in the position shown in the paper template,

Drill a hole through the wall measuring 30mm in diameter in the position shown in the paper template, 
marked the center before. Drainage occurs by gravity. For this reason, it is essential for the drain line 
to have a minimum downward inclination at least 3 degrees throughout its length. With this solution, 
you can drain the condensate moisture to a suitable place to do not cause any problems to your 
neighbours. 

This drainage method is more common use, and the discharge pipe goes outside where there is no 
problem to connect or to discharge it, this solution is OK for hot country and normal cold temperature 
outside. 

W ll b

k t h l

(P9)

Wall bracket holes (P9)

Drill the holes for anchoring the unit to the wall using preferably the 2 holes with 10mm diameter 
showed in black on the paper template. As the unit is installed on high wall, it is recommended that the 
bolts should be fixed very well.

7.4  Fastening the anchors (P10)

Insert the concrete anchors into the holes for the unit and tighten them inside the wall

Insert the concrete anchors into the holes for  the unit, and tighten them inside the wall. 

The anchor bolts provided require 10mm holes; the wall should be inspected to determine if provided 
bolts are useful or if it is necessary to use a different anchorage. The manufacture is not liable in case 
of underestimation of the structural consistency of the anchorage made at the time of installation.

7.5  Fitting the gratings 

After drilling the holes, the plastic gratings supplied with air conditioner need to be fitted on the wall.

1.When gratings is easy accessibility, you could fix the gratings from outside, it is recommended to 
fasten it to the wall with wall plugs and screws with a diameter of 6mm, and keep the fins in vertical 
position. (See image P11  )

2. When the air conditioner is installed in the high space, and  impossible to reach the gratings from
outdoor side,  you could fix the gratings from inside.

Put the silicon gel around of the soft grating, like Fig17.Then fold the outer grating in half, insert your 
arm inside the hole with the grating. Let the grating unfold and pull the grating toward you. With a little 

i

d

i l i

h 2

i

ill fi h

d f h h l

(P12 13 14)

patience and manipulation, the 2 gratings will fit the end of the holes. (P12,13,14) 

After fixing the outside grating,we could inject more gel inside the space between the grating and wall. 
(See P15,16)

The black silicon gel is just for reference, we could use white or transparent color gel to fix the outdoor 
grille.(P17)

The above installation solution is just for solid wall.

Содержание iCOOL

Страница 1: ...i per il benessere ed il risparmio www finteksrl com TECHNICAL MANUAL ICOOL IWARM Before installing the air conditioner carefully read the instructions iCOOL iWARM Pompe di Calore Monoblocco ad Alta Efficienza ...

Страница 2: ...n C 2 3 Overall Dimensions 4 Explosion view and parts list 5 Rated technical data 6 E l b l 6 Energy label 7 Installation 8 Electric wiring 9 Description of software operation 10 P i 10 Precaution 11 Ordinary maintenance 12 Problem and solution ...

Страница 3: ...a great look to the building as only 2x200mm holes are required The benefits of no outdoor unit are no sleeve no louvers and no rust ensuring low cost installation and maintenance The heat pump provides low operating costs when in heating mode R410a gas friendly refrigerant with high efficiency ozone Auto water evaporation in cooling and heating mode Auto water evaporation in cooling and heating m...

Страница 4: ...3 Overall Dimensions Note The external pipes are same Ø197mm ...

Страница 5: ...4 Explosion view and parts list 4 1 iCOOL Explosion view ...

Страница 6: ... 1 14 R131030006 3 way terminal block 1 15 128060209 Wire protection ring 1 16 R131130003 Condenser fan capacitor 2 17 R139010035 Power plug protection ring 1 18 R132040139 Power plug 1 19 R128030549 PMMA 1 20 R128030543 Front panel 1 20 R128030543 Front panel 1 21 R128030545 Front frame 1 22 R128030555 Outlet frame 1 23 R128030557 Flap1 1 24 R128030572 Flap2 1 25 R138140752 Insulation material fo...

Страница 7: ... Front cover EPP sponge 1 58 R138140716 Electrical box top sponge 1 59 R138140717 Electrical box side sponge1 1 60 R138140718 Electrical box side sponge2 1 61 R138140724 Right metal plate sponge 1 62 R138140696 Condenser insulation sponge 1 p g 63 R138140698 Evaporator insulation sponge 1 64 R138140729 Wall bracket insulation sponge 1 65 R138140701 Back metal plate sponge 1 66 R138140573 Capacitor...

Страница 8: ...4 2 iWARM Explosion view ...

Страница 9: ...030557 Flap1 1 14 R128030572 Flap2 1 15 R128030555 Outlet frame 1 16 R131060066 Step motor plap 2 17 R127041116 Right metal plate 1 18 R131040178 Indoor motor 1 19 R127020796 Evaporator motor support 1 20 R127020798 Indoor motor holder 2 21 R128060423 Bottom EPP 1 22 R128050021 Tangential fan 1 22 R128050021 Tangential fan 1 23 R122010207 Evaporator assy 1 24 R128060422 Upper EPP 1 25 R128060427 F...

Страница 10: ...e 1 43 R128060424 Condenser cover EPP 1 44 R127020803 Top metal plate 1 45 R127020801 Back metal plate 1 5 0 080 ac eta p ate 46 R131040175 Anticlockwise condenser fan 1 47 R131040176 Clockwise condenser fan 1 48 R138140701 Back metal plate sponge 1 49 R128030561 Outside grille 2 50 R128070006 Drainage pipe 1 51 R131170148 Remote control 1 52 R128040261 Remote control seat 1 53 R131100001 Battery ...

Страница 11: ...Air low m3 h 450 450 Outdoor Air low m3 h 450 450 Noise lever SPL dB A 49 49 Dehumidification capacity L 24h 12 5 12 5 Optional temperature remote control ć 18 30 18 30 Maximum external temperature eC 43 43 Minimum external temperature HP eC 5 5 Minimum external temperature HP eC 5 5 Fuse T3 15L V 250 250 Refrigerant R410a g 640 640 Dimension H W D cm 43 95 5 19 5 43 102 19 5 Net Weight Kg 40 42 T...

Страница 12: ......

Страница 13: ...7 Installation ...

Страница 14: ......

Страница 15: ......

Страница 16: ...until you are completely confident that there are no obstacles in the area you wish to drill and there are no obstructions which could be hidden by the construction of the wall for example electrical wiring water gas pipes or supporting lintels or beams Ensure that a spirit level is used as the air conditioner must be level Follow the installation instructions in full Fasten the template to the wa...

Страница 17: ...e holes for the unit and tighten them inside the wall The anchor bolts provided require 10mm holes the wall should be inspected to determine if provided bolts are useful or if it is necessary to use a different anchorage The manufacture is not liable in case of underestimation of the structural consistency of the anchorage made at the time of installation 7 5 Fitting the gratings After drilling th...

Страница 18: ...a proper place See P23 7 8 Fitting the air conditioner on anchors After checking again that the fastening anchors are securely fastened to the wall and that any necessary preparations for electric connection and condensate drainage have been made fasten the air conditioner to its supporting anchors See P24 Lift it up by holding the sides at the bottom slightly insert the outside fan rings into the...

Страница 19: ...8 ICOOL IWARM Electric wiring ...

Страница 20: ...ging room temperature see below table Indoor temp Indoor temp 20ć 20ć indoor 25ć indoor 25ć Running mode heating fan cooling St d d fi d 20ć 22ć 25ć Standard fixed setting temperature 20ć 22ć 25ć Note 1 When Auto mode is selected unit would check room temperature first and work with fixed mode as above accordingly Every 6 minutes unit would check room temperature again running mode would be change...

Страница 21: ...art Fan speed High speed Middle speed Low speed 1ć 1ć 2ć 5ć RT TS 9 3 3 Dry mode 1 Setting temperature range 18ć 30ćDŽ 2 Working conditions unit would work according to indoor temperature and setting temperature NO conditions Indoor fan motor Outdoor fan motor compressor Four way valve 1 RT ST Fixed with low speed Keep running no power supply 2 RT ST Works for 10 minutes then 2 RT ST Works for 10 m...

Страница 22: ...rse When unit is turned into heating mode or turned on four way valve will open 5 seconds earlier than compressor When heating mode is changed or unit is turned off four way valve will close 2 minutes later than compressor 5 Outdoor fan motor working conditions start or close same time as the compressor When unit goes into defrost or over heating protection it will work according to defrost or ove...

Страница 23: ...ose 2 F l ill k ft 1 i t 2 Four way valve will work after 1 minute 3 Compressor will work again after 30 seconds indoor fan will work with anti cold air function and defrost cycle is off Aux electrical heater will work as original mode if unit has this function Note 1 During defrost cycle yellow Timer led will flash with 1Hz frequency 2 Temperature detection is valid only when compressor is workin...

Страница 24: ... Note When setting Timer and Sleeping function same time unit will work with Timer function 9 3 7 PTC electrical heater function Used for iWARM 1 N t PTC l t i l h t f ti 1 No auto PTC electrical heater function 2 Manual PTC electrical heater function PTC would work under the following conditions a The unit is working in heating mode b Room temperature RT 26 ć When RT Ts 1 ć PTC would be on after ...

Страница 25: ...rol Step motor would control the flap panel moving run or stop according to the order from remote control 9 5 Protection function 9 5 1 Compressor 3 minutes delay protection a The compressor will run immediately when it works with first time b Compressor must stops for 3 minutes and reworks again Except defrost function in heating mode 9 5 2 Anti frozen protection in cooling and dry mode a If indo...

Страница 26: ...ged cycle 9 5 5 Indoor PG motor problem protection If indoor fan motor could not receive the feedback pulse for 5 seconds it would close Compressor If indoor fan motor could not receive the feedback pulse for 5 seconds it would close Compressor outdoor fan motor valve and aux electrical heater will close same time Indoor unit fan motor would run again after 10 seconds if still do not receive the s...

Страница 27: ...any product is used by or near children and pets and whenever the product is left operating and unattended Please note Before operating the product remove the air conditioner from its package and check it is in good condition Do not let children play with the packaging for example plastic bags Do not operate any product with a damaged cord or plug or after the air conditioner malfunctions has been...

Страница 28: ...R25 5 0K 1 7HPSe 5HVLVWDQFH YDOXH 7HPSe 5HVLVWDQFH YDOXH 7HPSe 5HVLVWDQFH YDOXH 7HPSe 5HVLVWDQFH YDOXH 23 7103 ...

Страница 29: ...r conditioner from the electrical supply Wipe external surfaces clean with a damp cloth only Do not use an abrasive cloth and or solvents as this may damage the surfaces Do not use excessively wet cloth or sponges as water stagnation could damage the air conditioner and compromise safety 11 3 Active carbon filter P34 The unit maybe includes active carbon filter which not only has the function of e...

Страница 30: ...ture goes down 5 The temperature is not properly set check it 6 The grids could be obstructed check and remove the eventual obstacles 7 Dampness in the room coming from walls carpet furnishing or similar p g p g 8 Wrong installation of the air conditioner 9 Wrong connection of the drainage pipe 10 Exhausted batteries 11 Wrong insertion of the batteries inside the remote control 12 Protection of th...

Страница 31: ...essere ed il risparmio Fintek srl via B Strozzi 6 47895 Domagnano Repubblica di San Marino Tel Fax 378 0549 901950 Cell 39 393 1808890 fintek finteksrl com Visit our website and discover all our products www finteksrl com ...

Отзывы: