LIMING PROCEDURE (CONTINUED)
13. When ready to apply slurry, install gasket and nozzle into boom.
14. Move agitator control to 3/4 speed FORWARD.
15. With the slurry pump clutch still engaged (turned on), open the discharge valve.
To decrease pump wear and increase discharge distance, it may, at
this point be desirable to close the recirculation valve. However, the
recirculation valve must be open BEFORE closing the discharge valve if the application of
slurry is to be interrupted. Failure to comply could result in minor or moderate personal
injury. Failure to comply could also result in product or property damage.
16. Apply the slurry. See APPLICATION OF SLURRY SECTION.
17. If another load is to be applied, start again at step 1. If finished, follow
CLEANING AND MAINTENANCE SECTION.