FIMER_PVS-50_60-TL-Quick Installation Guide_EN_RevB

8

PVS-50-TL

PVS-60-TL

AC output voltage range (V

ac min

...V

ac max

)

320...480 Vac 

(1)

384...571 Vac 

(1)

Maximum AC output current (I

ac max

)

80 A

Contributory fault current

92 A

Rated output frequency (f

r

)

50 / 60 Hz

Output frequency range  (f

min

...f

max

)

 47...53 / 57...63 Hz 

(2)

Rated power factor and adjustable range

> 0.995, 0...1 inductive/capacitive with max Smax

Total current harmonic distortion

< 3.%

Maximum AC cable cross-section allowed

95 mm

2

 copper

AC connection type

Screw terminal block, cable gland M63

Output Protection

Anti-islanding protection 

Complying with the local standard (active frequency drift combined with RoCoF techniques)

Maximum external AC overcurrent protection 100 A

Output overvoltage protection - Varistor

Yes

Output overvoltage protection - Surge Arrester Type II

Operating Performance

Maximum efficiency (η

max

)

98.4%

98.6%

Weighted efficiency (EURO/CEC)

98.2% / -

98.4%/-

Communication

Integrated communication interface

3x RS485, 2x Ethernet (RJ45), WLAN (IEEE802.11 b/g/n @ 2,4 GHz)

Communication protocol:

Modbus RTU / TCP (Sunspec compliant); Aurora Protocol

Remote monitoring services

Standard level access to Aurora Vision monitoring portal

Advanced features

Integrated Web User Interface; Display (option); Embedded logging and direct transferring of data to 

Cloud

Environmental

Ambient temperature range

-25...+60°C (-13...140°F) with derating over 45°C (113°F)

Storage temperature

-40°C...+85°C / -40°F...185°F

Relative humidity

4...100% condensing

Sound pressure level, typical

75 dB(A) @ 1 m

Maximum operating altitude

4000 m (13123 ft) with derating above 2000 m / 6561 ft

Classification of the degree of environmental 

pollution for the external environment

3

Environmental category

Outdoor

Physical Specs

Environmental protection degree

IP 65 (IP54 for cooling section)

Cooling system

Forced air

Dimensions (H x W x D)

750 mm x 1100 mm x 257 mm / 29.5” x 43.3” x 10.12”

Weight

70 kg / 154 lbs (SX version)

Mounting system

Wall bracket, horizontal support

Overvoltage category according to IEC 

62109-1

II (DC input)    III (AC output)

Safety

Isolation level

Transformerless

Marking

CE 

(5)

Safety class

I

1. The output voltage range may vary depending on the specific grid standards of each country.

2. The output frequency range may vary depending on the specific grid standards of each country. 

3. In case of failure, it is limited by the external protection device on the AC circuit.

4. Please refer to the document “String inverters – Product manual appendix” available at 

www.fimer.com

 for information on the quick-fit connector brand and model used in the inverter

5. Only 50Hz

6. Max. installable size 20A

Note. The features that are not specifically mentioned in this data sheet are not included in the product

For more information 

please contact your 

local FIMER 

representative or visit:

fimer.com

We reserve the right to make technical changes or 

modify the contents of this document without prior notice. 

With regard to purchase orders, the agreed particulars 

shall prevail. FIMER does not accept any responsibility 

whatsoever for potential errors or possible lack of 

information in this document.

We reserve all rights in this document and in the 

subject matter and illustrations contained therein. Any 

reproduction, disclosure to third parties or utilization of 

its contents – in whole or in parts – is forbidden without 

prior written consent of FIMER. Copyright© 2020 FIMER. 

All rights reserved.

23-06-2020

Содержание PVS-50-TL

Страница 1: ...allation information provided in the product manual must be read and followed The technical documentation for the product is available at the website The device must be used in the manner described in the manual If this is not the case the safety devices guaranteed by the inverter might be ineffective APPLY HERE THE WIRELESS IDENTIFICATION LABEL ...

Страница 2: ...ow of air around the inverter is not blocked so as to prevent overheating Do not install near flammable substances minimum distance 3 m Do not install near on wooden walls or near flammable surfaces Do not install in rooms where the people live or where the prolonged presence of people or animals is expected Installation of these models can be carried out vertically or horizontally with a maximum ...

Страница 3: ... connector 33 DC disconnect switch 58 RS485 2 line 120Ohm termination resistor switch 11 Locking brakets attachment point 34 Negative side string fuses 59 RS485 2 communication card housing 12 Ethernet cable gland 35 Positive side string fuses 60 RS485 Main terminal block J5 13 Service cable gland 36 AC overvoltage surge arresters 61 Battery housing 14 Handle 37 Protective earth terminal internal ...

Страница 4: ...rminal internal 37 2x Protective earth terminal external 16 4 Configuration bar for paralleled input channels and M5x12 screws with plain and split washers 1 3 Key for front door key lock 8 Technical documentation 1 6 Mounting instructions The mounting bracket 1 can be used to install the inverter on a vertical or horizontal support 1 Position the bracket 1 perfectly level on the support and use i...

Страница 5: ...nsert must be installed on the cable FIG 9 As alternative is possible to connect the earth cable to the protective earth terminal external 16 positioned on the left side of the mechanics As per the protective earth terminal internal 37 following to the sequence illustrated in the below figure and tightening it to a torque of 11Nm A ring cable lug suitable for aM6 size threaded insert must be insta...

Страница 6: ... with a display the error message appears on the display READ THE MANUAL E Refer to the product manual for a description of error warning codes appearing on the display for inverters with a display 11 Commissioning ATTENTION A Before starting the inverter commissioning procedure ensure that all the checks indicated in the previous sections of this Quick Installation Guide have been correctly perfo...

Страница 7: ... server TAKE NOTE OF THE LINKS STEP 3 Set the Date Time and Time Zone STEP 4 Set the inverter grid standard and configure the input channels By clicking FINISH the wizard completes the configuration procedure after the settings are confirmed the inverter restarts ATTENTION A From the moment the grid standard is selected there will be 24 hours available to make any changes to the grid standard afte...

Страница 8: ...n of the degree of environmental pollution for the external environment 3 Environmental category Outdoor Physical Specs Environmental protection degree IP 65 IP54 for cooling section Cooling system Forced air Dimensions H x W x D 750 mm x 1100 mm x 257 mm 29 5 x 43 3 x 10 12 Weight 70 kg 154 lbs SX version Mounting system Wall bracket horizontal support Overvoltage category according to IEC 62109 ...

Отзывы: