Sprayer and Pump FAQs:

 

 

♦ 

Why does the pump not run all the time? 

 

This is an on

-

demand pump and only runs when a discharge is open or a leak in the 

system.

 

♦ 

Why does the pump surge while using the spray gun?

  

Low flow/high pressure may cause the pump to surge (or cycle).     

Typically the spray wand is adjusted at too fine of a mist, to overcome, adjust the nozzle for a higher flow.

 

♦ 

How do I adjust the pressure?

 

Pressure can only be adjusted by opening the pressure adjust (bypass) valve to allow some of 

your water or solution to return to the tank (if equipped).

 

♦ 

Pump quit and will not run, what do I need to do?

  

Squeeze trigger on spray gun to ensure that the system isn

t just pressur-

ized up with discharges closed. Check electrical connections, ensure switch is on. Check fuses. Check for proper voltage. Check 
pressure switch.

 

♦ 

Low flow or no flow at all, what do I need to check for?

 

Check for a clogged intake hose and/or intake strainer. Check for  

proper voltage. You will need to occasionally check your intake strainer to ensure that it is clean of any debris.

 

♦ 

What is causing the fuse to blow each time I turn the pump on?

  

Check for excessive voltage. Improper adjustment of the 

pressure switch. Damaged or defective wire harness or defective pressure switch.

 

 

Warning:

 

Ensure the wiring harness does not become pinched or damaged in any way. This may damage the pump or cause the 

wiring harness to overheat, resulting in a melt down or fire.

 

 

Motor is NOT Running 

-

 Checking the Pressure Switch:

 

If motor is not running and you

ve checked the following: for loose wiring connections, fuse, the switch on the lead wire was 

ON

” 

and sprayer was connected to a fully charged battery, but motor won

t run, then it

s time to check to see if the 

 

pressure switch is bad.

 

• 

Remove the cover off the 

1” 

square box (pressure switch) on the head of the pump, the cover is 

held on by one phillips

-

head screw. This will expose the two red wires.

 

• 

With the pump connected to a good 12 volt power source and everything on.

 

• 

Slip the two red wires off the terminals and touch them together. 

 

 

♦ 

If the motor runs, it means the pressure switch is bad and needs to be replaced. 

 

♦ 

If motor still doesn

t run, try bypassing the switch in the lead wire or using   another lead wire. 

 

Even if a tester shows power to the pressure switch, still try this test.

 

 

Warning:

 It is NOT recommended to run the pump this way, as the pump will continue to run and 

not shut off. 

 

 

This could result in blown hoses when all discharges are closed or premature failure 
of the pump completely.

 

 

Motor Running

-

BUT No Pressure 

-

 

-

 Cleaning the Check Valve:

 

If you

re experiencing little to no pressure or the pump is not priming and filter screen 

is clean and plumbing is good with no leaks, you may need to clean the check valve.

 

• 

Remove the head of the pump, which is held on by 7 screws.

 

• 

The first piece inside the head of the pump is called a check valve, it

s the part re-

sponsible for building up pressure and pumping water/solution through the lines. 

 

• 

Clean the check valve under hot, soapy water (such as a good grade dish soap). 

 

• 

Give it a very light scrubbing with something like an old toothbrush, something with soft bristles.

 

• 

Then let it soak for about an hour or so in the hot soapy solution and replace in the pump and reassemble 
the pump.

 

 

Most times this will restore most, if not all of the prime of a pump.

 

If you

re still having issues with pressure after this step, it would be recommended to replace this part.

 

Before Troubleshooting or Attempting to Service the Pump:

 

♦ 

Review Troubleshooting Chart: 

Do Not attempt to repair until steps below are followed.

 

♦ 

Personal Protective Gear: 

Wear protective gear when servicing pump.

 

♦ 

Disconnect Power: 

Disconnect the power to the pump and relieve the pressure from the system.

 

♦ 

Empty and Flush 

pump system with water, never attempt to service the pump until it has been emptied and flushed.

 

♦ 

Perform Repairs: 

Follow directions provided in the troubleshooting section to repair the pump.

 

♦ 

Test: 

Always test the pump for leaks with plain water after any repairs before using.

 

Содержание LG-45-SS

Страница 1: ...number above Our technical support representatives will be happy to help you In most cases a customer service rep can resolve the problem over the phone To obtain prompt efficient service always remember to give the following information Correct Part Description and or part number Model number and Serial Number Part descriptions and numbers can be obtained from the illustrated parts list section s...

Страница 2: ...yer Exercise Caution in vehicle handling when towing hauling a filled sprayer to avoid loss of control or overturning Keep Sprayer and Spray materials away from other people children and pets Do Not Turn on Power to the sprayer until ready to spray in order to avoid unintentional spray release Do Not Use on steep slopes A full sprayer could cause loss of control or overturn sprayer and vehicle Alw...

Страница 3: ... chemical label s before application Operation The pumping system draws solution from the tank through the strainer and to the pump The pump forces the solution under pressure to the handgun Fill the tank part way with water and then add the desired amount of chemical to be sprayed Finish filling tank to proper level Only fill the tank with what you re going to spray in a day never leave chemicals...

Страница 4: ...u facturer s instructions on disposal of all waste water from the sprayer Tank Care Maintenance Warning Do not use the tank as a container for fuel oils kerosene gasoline or any other petroleum distillate product All polyole fins are softened and permeated by such products In an enclosed area the vaporization of these materials from the outside surface of the tank could create a dangerous conditio...

Страница 5: ...rges Low flow may cause pump to surge Spray Wand is adjusted to small or fine of a Check for defective pressure switch Check for leaks in the discharge line Check for debris in nozzle orifice Fuse blows Excessive voltage Improper adjustment of pressure switch Damaged or defective wiring harness Defective pressure switch Pump continues to run Check for worn or dirty check valve Check for empty prod...

Страница 6: ...ith the pump connected to a good 12 volt power source and everything on Slip the two red wires off the terminals and touch them together If the motor runs it means the pressure switch is bad and needs to be replaced If motor still doesn t run try bypassing the switch in the lead wire or using another lead wire Even if a tester shows power to the pressure switch still try this test Warning It is NO...

Страница 7: ...Page 7 Exploded View Parts List LG 45 SS 5303260 Manifold Detail ...

Страница 8: ...ice under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable period of time For ...

Отзывы: