Step 1:

 

Attach the (2) Hose Wraps to the 
side of the tank with Phillips 
Head Screws

 

 

Step 2:

 

Thread Pressure Gauge into open 
port on manifold, as shown.

 

 

Thread Lid on to tank.

 

Step 1

 

Step 2

 

IMPORTANT: 

Remove tank lid and be sure the tank is clean and free of any foreign material. Rinse tank out of any tank residue 

before filling with water to test.

 

 

Testing the Sprayer

 

NOTE: 

It is VERY important to test this sprayer with plain water before actual spraying is 

attempted. This will enable you to check the sprayer for leaks without the possibility of 
losing any expensive chemicals.

 

 

Fill the tank about 1/2 full with plain water and drive to the starting place for spraying. 

 

 

Adjust the pressure by turning the 

ON/OFF

” 

valve lever on the Press Adj. valve (Detail B). 

Make sure your pattern is sufficient. You may down

-

pressure the system by 

bypassing

’ 

solution back into the tank. This is achieved by opening the press adj. valve. Regulating 
pressure is also done in this manner.

 

 

Read the operating instructions and initially begin spraying by closing the 

Pressure 

 

Adjust

’ 

valve and squeezing the trigger on the spray gun. This will enable the air in the line 

to be eliminated (purged) through the tip, while building pressure. When everything tests 
all right (no leaks and good pressure), add the desired chemicals to the mixture and water 
combination and start your spraying operation. 

 

 

Conditions of weather and terrain must be considered when setting the sprayer. Do not 
spray on windy days. Protective clothing must be worn in some cases.

 

 

Be sure to read the chemical label(s) before application!

 

 

Operation

 

The pumping system draws solution from the tank, through the strainer and to the pump. 
The pump forces the solution under pressure to the handgun.

 

 

Fill the tank part way with water and then add the desired amount of chemical to be sprayed. Finish filling tank to proper level. 

 

 

Only fill the tank with what you

re going to spray in a day, never leave chemicals sit in tank.

 

 

Connect the lead wire to a fully charged 12 volt battery. You may use either a stand

-

alone battery or the battery on your towing 

vehicle. Connect to the positive (red) terminal first, then connect to the negative (black) terminal. Then connect the end of the lead 
wire to the end of the pump. When disconnecting, disconnect the end of the pump wire from the lead wire, then disconnect the 
negative (black) connection and finally the positive (red) connection. The lead wire has an On/Off switch to activate the pump. 

-

” 

is on and 

O

” 

is off.

 

Turn the pump on and by depressing the 

-

” 

side of the rocker switch. The pump is equipped with a pressure switch that is pre

-

set 

at the factory to shut the pump off when all discharges are closed.

 

The pump will turn back on when one of the following actions occurs:

 

 

Handgun lever is squeezed to spray the handgun.

 

 

Bypass valve is opened to re

-

circulate solution back into the tank.

 

 

When spraying with either the boom (if applicable) or the handgun, pressure may be reduced by slowly opening the Press. ADJ. 
(bypass) valve until desired pressure is achieved. Opening the valve decreases pressure, closing the valve increases pressure. Adjust 
the pressure and spray as you did in the testing procedure.

 

Manifold Valves CLOSED

 

Detail A

 

Assembly Instructions:

 

**The Sprayer is now ready to TEST w/plain water before actual use**

 

Содержание LG-45-SS

Страница 1: ...number above Our technical support representatives will be happy to help you In most cases a customer service rep can resolve the problem over the phone To obtain prompt efficient service always remember to give the following information Correct Part Description and or part number Model number and Serial Number Part descriptions and numbers can be obtained from the illustrated parts list section s...

Страница 2: ...yer Exercise Caution in vehicle handling when towing hauling a filled sprayer to avoid loss of control or overturning Keep Sprayer and Spray materials away from other people children and pets Do Not Turn on Power to the sprayer until ready to spray in order to avoid unintentional spray release Do Not Use on steep slopes A full sprayer could cause loss of control or overturn sprayer and vehicle Alw...

Страница 3: ... chemical label s before application Operation The pumping system draws solution from the tank through the strainer and to the pump The pump forces the solution under pressure to the handgun Fill the tank part way with water and then add the desired amount of chemical to be sprayed Finish filling tank to proper level Only fill the tank with what you re going to spray in a day never leave chemicals...

Страница 4: ...u facturer s instructions on disposal of all waste water from the sprayer Tank Care Maintenance Warning Do not use the tank as a container for fuel oils kerosene gasoline or any other petroleum distillate product All polyole fins are softened and permeated by such products In an enclosed area the vaporization of these materials from the outside surface of the tank could create a dangerous conditio...

Страница 5: ...rges Low flow may cause pump to surge Spray Wand is adjusted to small or fine of a Check for defective pressure switch Check for leaks in the discharge line Check for debris in nozzle orifice Fuse blows Excessive voltage Improper adjustment of pressure switch Damaged or defective wiring harness Defective pressure switch Pump continues to run Check for worn or dirty check valve Check for empty prod...

Страница 6: ...ith the pump connected to a good 12 volt power source and everything on Slip the two red wires off the terminals and touch them together If the motor runs it means the pressure switch is bad and needs to be replaced If motor still doesn t run try bypassing the switch in the lead wire or using another lead wire Even if a tester shows power to the pressure switch still try this test Warning It is NO...

Страница 7: ...Page 7 Exploded View Parts List LG 45 SS 5303260 Manifold Detail ...

Страница 8: ...ice under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable period of time For ...

Отзывы: