IMPORTANT: 

Remove tank lid and be sure the tank is clean and free of 

any foreign material. Rinse tank out of any tank residue before filling with 

water to test. 

 

Testing the Sprayer 

NOTE: 

It is VERY important for you to test your sprayer with plain water before actual 

spraying is attempted. This will enable you to check the sprayer for leaks without 

the possibility of losing any expensive chemicals. 

  

Fill the tank about 1/2 full with plain water and drive to the starting place for spraying.  

 

When you are ready to spray, turn the boom valve to the “on” position (Detail A). This will start 

solution spraying from the tips of the boom. The pressure will decrease slightly when the 

boom is spraying.  

Adjust the pressure by turning the “ON/OFF” valve lever on the bypass line valve (Detail B). 

Make sure your pattern is sufficient. You may down-pressure the system by ‘bypassing’ solu-

tion back into the tank. This is achieved by opening the bypass valve. Regulating pressure is 

done in this manner. 

Read the operating instructions and initially begin spraying by closing the ‘Pressure Adjust’ 

valve and opening the boom line valve (Detail A). This will enable the air in the line to be elimi-

nated (purged) through all the tips, while building pressure. When everything tests all right (no 

leaks and good pressure), add the desired chemicals to the mixture and water combination 

and start your spraying operation. Adjust the pressure and spray as you did in the testing 

procedure. 

Conditions of weather and terrain must be considered when setting the sprayer. Do not spray 

on windy days. Protective clothing must be worn in some cases. 

 

Be sure to read the chemical label(s) before application! 

 

Operation 

The pumping system draws solution from the tank, through the strainer and to the pump. The 

pump forces the solution under pressure to the handgun or boom nozzles. 

 

NOTE: 

Read and follow the Volt Edge instructions, later in this manual, for charging and  

operation of the 20Vmax Lithium Ion System 

Fill the tank part way with water and then add the desired amount of chemical to be sprayed. 

Finish filling tank to proper level. Turn the pump on and by depressing the “-” side of the rock-

er switch. The pump is equipped with a pressure switch that is pre-set at the factory to shut 

the pump off when all discharges are closed. 

 

The pump will turn back on when one of the following actions occurs: 

 

Handgun lever is squeezed to spray the handgun. 

 

Boom valve is opened to broadcast spray with the boom. 

 

Bypass valve is opened to re-circulate solution back into the tank. 

 

Rotating the adjustable nozzle tip on the handgun will change the tip pattern from a 
straight stream to a cone pattern (fine mist)

 

 

 

The (3) nozzles are fixed at 17-1/2” spacing

 

 

All (3) nozzles spraying at the same time will allow a maximum coverage of 30 feet

 

 

The center nozzle will spray an 80” swath

 

 

Each of the (3) nozzles has a shutoff valve, so you can shut off each nozzle individually. This may help in achieving the actual coverage needed 
for your application.

 

 

When spraying with either the boom or the handgun, pressure may be reduced by slowly opening the bypass valve until desired pressure is achieved. 

Opening the valve decreases pressure, closing the valve increases pressure. When spraying with the boom, the proper method to set the pressure is 

to open the boom valve completely and if a lower pressure is desired, then slowly open the bypass valve until that pressure is obtained. 

For the safest and most efficient chemical application, you will need to calibrate your sprayer using the tip and speed charts. Once you have deter-

mined the proper speed and pressure settings, you will need to consult your chemical label for the amount of chemical to be added to the tank. Read 

the entire label. Use only according to label directions. 

 

Calibration 

Chemical labels may show application rates in gallons per acre, gallons per 1000 square feet or gallons per 100 square feet. You will note that the tip 

chart shows 3 of these rating systems. Once you know how much you are going to spray, then determine (from the tip chart) the spraying pressure 

(PSI), and the spraying speed (MPH). 

Determining the proper speed of the pulling vehicle can be done by marking off 100, 200 & 300 feet. The speed chart indicates the number of seconds 

it takes to travel the distances. Set the throttle and with a running start, travel the distances. Adjust the throttle until you travel the distances in the 

number of seconds indicated by the speed chart. Once you have reached the throttle setting needed, mark the throttle location so you can stop and go 

again, returning to the same speed. 

Add water and proper amount of chemical to the tank and drive to the starting place for spraying. 

Manifold Valves CLOSED 

Detail A 

Detail B 

Содержание 5303068

Страница 1: ...mes with an On Off shut off valve located at the inlet location of the tank towards the underside See Detail A You must make sure the valve is in the open position before using your sprayer Detail A OWNER S MANUAL BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 831 0027 MONDAY FRIDAY 8 00 AM TO 5 00 PM CST If you should have a question or experience a problem with your Fimco Industr...

Страница 2: ...3068 Contents of Parts Bag 5281511 Contents of Bracket Kit 5278138 Wet Boom Sub Assembly 5275712 Tank Plumbing Pre Assembly Owner s Manual End Nozzle 5275122 Pkg of 2 5275713 Lid w Lanyard 5058188 Wireless Remote 5164291 20V 1A Lithium Battery Charger 5164281 ...

Страница 3: ... handles which extend beyond the back of the tank are facing you and just hanging over the edge of the table or flat surface you are assembling this on Secure the boom mounting brackets to the tank mounting brackets with Cam handles as shown in Detail A You can position them as needed within the slot on the bracket Just be sure that the surfaces of both brackets are even with each other You are no...

Страница 4: ...fixed to your boom tube Follow the instructions below to attach these properly to the boom tube as shown Assembled End Nozzle 1 Start by sliding Item 4 3 2 onto the boom tube Item 1 as shown leaving about 1 2 to 3 4 between the end of the boom tube and Item 2 Make sure the Long portion of Item 3 is facing the nozzle end 2 Slide the complete end nozzle assembly onto the stainless steel boom tube wi...

Страница 5: ...n securely DO NOT OVER TIGHTEN Detail B Screw the lid onto the tank Place the end of the lanyard through the tab in the tank This is so the lid can hang off the tank when filling rinsing the tank out Detail C Locate the 2 clips and 2 phillips head machine screws from the parts bag A phillips head screwdriver is required for this step Place a screw through the hole in the clip and bring it up to th...

Страница 6: ...ff when all discharges are closed The pump will turn back on when one of the following actions occurs Handgun lever is squeezed to spray the handgun Boom valve is opened to broadcast spray with the boom Bypass valve is opened to re circulate solution back into the tank Rotating the adjustable nozzle tip on the handgun will change the tip pattern from a straight stream to a cone pattern fine mist T...

Страница 7: ...the tank so that when the pump is turned on you can pump the antifreeze throughout the entire plumbing system including the bypass Make sure to operate the boom and handgun until you see pink fluid spraying from the nozzles Leave any remaining antifreeze in the tank Be fore your next usage rinse the antifreeze from the sprayer with clean water It is nearly impossible to drain all of the water from...

Страница 8: ...e Check for restriction in the discharge line Check for debris in nozzle orifice Check for clogged strainer Check for proper voltage try another battery or recharge battery Pulsating flow surging Low flow may cause pump to surge Spray wand is adjusted for a small or fine spray pattern Slightly open bypass if applicable to overcome If needed pressure switch may need to be adjusted adjust a quarter ...

Страница 9: ...ve Remove the head of the pump which is held on by 7 screws The first piece inside the head of the pump is called a check valve it s the part responsible for building up pressure and pumping water solution through the lines Clean the check valve under hot soapy water such as a good grade dish soap Give it a very light scrubbing with something like an old toothbrush something with soft bristles The...

Страница 10: ...isk of injury basic safety precautions should always be followed including Charge battery packs only in Volt Edge 20V max Lithium ion compatible chargers Do not store or charge the battery pack in locations where the temperature may reach above 95 F 35 C or below 40 F 4 C Do not use the battery pack in locations where the temperature may reach above 120 F 49 C or below 4 F 20 C Warning Never attem...

Страница 11: ...y Chargers DOE energy conser vation standards specified in the Code of Federal Regulations at 10 CFR 430 32 z This device complies with CEC Section 1605 1 w of energy efficiency standars for federally regulated battery chargers of California Code of Regulations This device complies with NRCAN EEV CSA C381 2 17 May 2017 and Canada s Energy Efficiency Regulations This device complies with cETLus cer...

Страница 12: ...d and it is fully seated 4 Press the power button and confirm the green LED turns on Signaling the power is on 5 Test the remote by pressing the OFF button on the remote and both green and red receiver LEDs will turn on Signaling the power output is off while the power is on 6 Press the ON button on the remote The red LED will turn off and power output will return 7 Press the power button again to...

Страница 13: ...f this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit differe...

Страница 14: ...Page 14 Exploded View Parts List 20V 25 BL ATV 5303068 ...

Страница 15: ...fold Detail See Previous Page for Part Numbers Intake Detail See Previous Page for Part Numbers Boomless Wet Boom Assembly Exploded View Parts List 5275260 Center Nozzle Assembly 5275123 End Nozzle Assembly 5275122 ...

Страница 16: ...obtain warranty service under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable...

Отзывы: