background image

Page 3 

 

DO

 

 

Clean and rinse your pump after each use with Fimco Tank 
Neutralizer 

 

Winterize your pump or sprayer by rinsing, draining and  
running RV Antifreeze through it before storing for the winter. 

 

Use clean water for your spray mixture 

 

Store inside a building when not in use. 

DON’T

 

 

Use to pump bleach. 

 

Use to pump petroleum products such as diesel fuel,    
gasoline or kerosene 

 

Leave your pump sit with spray mixture in it for extended 
periods 

 

Use dirty or unfiltered water for spraying 

Troubleshooting the Pump: 

Motor does not run: 

 

Check for loose wiring connection(s). 

 

Make sure the 'ON/OFF' switch in the lead wire assembly 

is in the 'ON' position. "I" is the 'ON' position and 'O' is 

the 'OFF' position. 

 

Check for defective pressure switch. Make sure you are 

connected to a good  12 volt power source. Make sure 

any on/off switches are in the 'on' position.  Remove the 

cap to the pressure switch. Pull both red wires off of their 
terminals, and touch the two ends together. If your pump 

runs when you do this, your   pressure switch will need to 

be replaced. 

 

Check the fuse. 

 

Check for low voltage at the power supply. 

 

 

Pump does not prime: 

 

Check for air leaks in supply line. 

 

Check for debris in the check valve assembly. 

 

Check for defective check valve. 

 

Check for clogged strainer/filter. 

 

Check for cracks in the pump housing. 

 

Check for empty product supply. 

 

Low Pressure/Low Flow: 

 

Check for leaks in the discharge line. 

 

Check for restriction in the discharge line. 

 

Check for debris in nozzle orifice. 

 

Check for clogged strainer. 

 

Check for proper voltage—try another 12-volt battery. 

Pulsating flow (surging): 

 

Low flow may cause pump to surge. 

 

Spray wand is adjusted for a small or fine spray pattern. 

 

Slightly open bypass (if applicable) to overcome. 

 

If needed, pressure switch may need to be adjusted—

adjust a quarter turn at a time clockwise until surging 

stops. 

 

Check for defective pressure switch. 

 

Check for leaks in the discharge line. 

 

Check for restriction in the discharge line. 

 

Check for debris in nozzle orifice. 

 

Discharge hose may be too long. 

 

Check for clogged strainer. 

 
Motor continues to run after discharge is shut off: 

 

Check for empty product supply. 

 

Check for open bypass valve. (if equipped) 

 

Check for low voltage. 

 

Check for leak in discharge line. 

 

Check for defective pressure switch. 

 

System has leaks. 

 

Fuse blows: 

 

Excessive voltage. 

 

Improper adjustment of pressure switch. 

 

Damaged or defective wiring harness. 

 

Half-moon & counterweight are sticking. 

 

Defective pressure switch. 

Pump Model:  5281371 

2.4 GPM, 60 PSI 

Available Replacement Parts 

Replacement Pump:  5151087 

 

 

 

 

 

 

Includes:   

 

 

 

 

 

 

 

1/2” MNPT Port Kit Fitting  

 

 

 

 

 

 

 

 

#5168832 

 

 

 

 

 

 

 

1/2” Hose Barb Port Kit Fitting  

 

 

 

 

 

 

 

 

#5168833 

 

 

 

 

 

 

 

3/8” Hose Barb Port Kit Fitting  

 

 

 

 

 

 

 

 

#5168836 

Содержание 5301304

Страница 1: ...u have purchased the optional trailer kit or optional boom assembly BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 831 0027 MONDAY FRIDAY 8 00 AM TO 5 00 PM CST If you should have a question or experience a problem with your Fimco Industries Product Visit our website www fimcoindustries com or call the Toll free number above Our technical support representatives will be happy to he...

Страница 2: ...gun Bypass valve is opened to re circulate solution back into the tank When spraying with the handgun pressure may be reduced by slowly opening the bypass valve until desired pressure is achieved Opening the valve decreases pressure closing the valve increases pressure Maintenance During After Spraying Periodically check the strainer and clean the screen on your intake line Proper care and mainten...

Страница 3: ...alve Check for clogged strainer filter Check for cracks in the pump housing Check for empty product supply Low Pressure Low Flow Check for leaks in the discharge line Check for restriction in the discharge line Check for debris in nozzle orifice Check for clogged strainer Check for proper voltage try another 12 volt battery Pulsating flow surging Low flow may cause pump to surge Spray wand is adju...

Страница 4: ...ed to a good 12 volt power source and everything on Slip the two red wires off the terminals and touch them together If the motor runs it means the pressure switch is bad and needs to be replaced If it still doesn t run try bypassing the switch in the lead wire or using another lead wire Even if a tester shows power to the pressure switch it still could be the switch in the wire that is causing th...

Страница 5: ...Page 5 See Plumbing Detail Next Page Exploded View SK 61 12V 5301304 Refer to Parts List Next Page for Part Numbers Loom Clamp for Handgun Hose ...

Страница 6: ...Page 6 Parts List SK 61 12V 5301304 Plumbing Detail Refer to the Parts List Above for Part Numbers Intake Hose Bypass Hose ...

Страница 7: ...Page 7 NOTES ...

Страница 8: ...ain warranty service under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable pe...

Отзывы: