Manifold Valves CLOSED 

IMPORTANT: 

Remove tank lid and be sure the tank is clean and free of 

any foreign material. Rinse tank out of any tank residue before filling with 

water to test.

 

 

Testing the Sprayer 

NOTE: 

It is VERY important for you to test your sprayer with plain water before actual 

spraying is attempted. This will enable you to check the sprayer for leaks without 

the possibility of losing any expensive chemicals. 

  

Fill the tank about 1/2 full with plain water and drive to the starting place for spraying.  

 

When you are ready to spray, turn the boom valve to the “on” position (Detail A). This will start 

solution spraying from the tips of the boom. The pressure will decrease slightly when the 

boom is spraying.  

Adjust the pressure by turning the “ON/OFF” valve lever on the bypass line valve (Detail B). 

Make sure your pattern is sufficient. You may down-pressure the system by ‘bypassing’ solu-

tion back into the tank. This is achieved by opening the bypass valve. Regulating pressure is 

done in this manner. 

 

Read the operating instructions and initially begin spraying by closing the ‘Pressure Adjust’ 

valve and opening the boom line valve (Detail A). This will enable the air in the line to be elimi-

nated (purged) through all the tips, while building pressure. When everything tests all right (no 

leaks and good pressure), add the desired chemicals to the mixture and water combination 

and start your spraying operation. Adjust the pressure and spray as you did in the testing 

procedure. 

Conditions of weather and terrain must be considered when setting the sprayer. Do not spray 

on windy days. Protective clothing must be worn in some cases. 

 

Be sure to read the chemical label(s) before application! 

 

Operation 

The pumping system draws solution from the tank, through the strainer and to the pump. The 

pump forces the solution under pressure to the handgun or boom nozzles. 

 

Connect the lead wire to a fully charged 12 volt battery. You may use either a stand-alone 

battery or the battery on your towing vehicle. Connect to the positive (red) terminal first, then 

connect to the negative (black) terminal. Then connect the end of the lead wire to the end of 

the pump. When disconnecting, disconnect the end of the pump wire from the lead wire, then 

disconnect the negative (black) connection and finally the positive (red) connection. The lead 

wire has an On/Off switch to activate the pump. “-” is on and “O” is off. 

 

Fill the tank part way with water and then add the desired amount of chemical to be sprayed. 

Finish filling tank to proper level. Turn the pump on and by depressing the “-” side of the rock-

er switch. The pump is equipped with a pressure switch that is pre-set at the factory to shut 

the pump off when all discharges are closed. 

 

The pump will turn back on when one of the following actions occurs: 

 

Handgun lever is squeezed to spray the handgun. 

 

Boom valve is opened to broadcast spray with the boom. 

 

Bypass valve is opened to re-circulate solution back into the tank. 

 

When spraying with either the boom or the handgun, pressure may be reduced by slowly 

opening the bypass valve until desired pressure is achieved. Opening the valve decreases 

pressure, closing the valve increases pressure. When spraying with the boom, the proper 

method to set the pressure is to open the boom valve completely and if a lower pressure is desired, then slowly open the bypass valve until that pres-

sure is obtained. 

 

For the safest and most efficient chemical application, you will need to calibrate your sprayer using the tip and speed charts. Once you have deter-

mined the proper speed and pressure settings, you will need to consult your chemical label for the amount of chemical to be added to the tank. Read 

the entire label. Use only according to label directions. 

 

Calibration 

Chemical labels may show application rates in gallons per acre, gallons per 1000 square feet or gallons per 100 square feet. You will note that the tip 

chart shows 3 of these rating systems. Once you know how much you are going to spray, then determine (from the tip chart) the spraying pressure 

(PSI), and the spraying speed (MPH). 

 

Determining the proper speed of the pulling vehicle can be done by marking off 100, 200 & 300 feet. The speed chart indicates the number of seconds 

it takes to travel the distances. Set the throttle and with a running start, travel the distances. Adjust the throttle until you travel the distances in the 

number of seconds indicated by the speed chart. Once you have reached the throttle setting needed, mark the throttle location so you can stop and go 

again, returning to the same speed. 

 

Add water and proper amount of chemical to the tank and drive to the starting place for spraying. 

Detail A 

Detail B 

Содержание 5301064

Страница 1: ...ssemble the sprayer After assembly is complete and before testing your sprayer make sure you connect the electrical hook up to the end of your pump and clip the clips to a fully charged battery OWNER S MANUAL BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 831 0027 MONDAY FRIDAY 8 00 AM TO 5 00 PM CST If you should have a question or experience a problem with your Fimco Industries P...

Страница 2: ...arts Bag 5278315 Tank Lid Lanyard 5058188 15 20 Gallon Trailer Bracket Kit 5277727 Tank Frame Pre Assembly 2 Nozzle Boom Assembly 5277774 2 Tires Wheels 5021092 Owner s Manual Contents of your sprayer s carton LG 1500 303 ...

Страница 3: ... doing this to get the axle through both holes Center the axle about the frame as best as possible Slide a wheel spacer onto the axle Now slide a wheel over the axle and up against the wheel spacer Make sure the valve stems of the wheels are facing outward Place a cotter pin through the hole at the end of the axle Using a needle nose pliers or similar tool bend the pins so that they will not slip ...

Страница 4: ... an 8 lanyard attached to it Slide the lanyard through the hole in the tab at the top of the tank This is so the lid can hang or be retained onto the tank while you are filling or rinsing the tank out This should help prevent loss or damage of the lid Screw the lid onto the tank Hand tight should be sufficient screw the pressure gauge into the manifold Hand tight should be sufficient Step 6 Step 7...

Страница 5: ...n disconnect the negative black connection and finally the positive red connection The lead wire has an On Off switch to activate the pump is on and O is off Fill the tank part way with water and then add the desired amount of chemical to be sprayed Finish filling tank to proper level Turn the pump on and by depressing the side of the rock er switch The pump is equipped with a pressure switch that...

Страница 6: ...ufacturer s instructions on disposal of all waste water from the sprayer Winter Storage Prepare the sprayer for end of season storage by running RV antifreeze through the system This will keep internal parts lubricated protect against corrosion and keep the unit from freezing Note RV antifreeze is non toxic and biodegradable and generally safer for the environment than automotive antifreeze Before...

Страница 7: ...heck for defective check valve Check for clogged strainer filter Check for cracks in the pump housing Check for empty product supply Low Pressure Low Flow Check for leaks in the discharge line Check for restriction in the discharge line Check for debris in nozzle orifice Check for clogged strainer Check for proper voltage try another 12 volt battery Pulsating flow surging Low flow may cause pump t...

Страница 8: ...ed to a good 12 volt power source and everything on Slip the two red wires off the terminals and touch them together If the motor runs it means the pressure switch is bad and needs to be replaced If it still doesn t run try bypassing the switch in the lead wire or using another lead wire Even if a tester shows power to the pressure switch it still could be the switch in the wire that is causing th...

Страница 9: ...ter screen Start your pump and before it shuts off reach down and shut the valve to the Closed position lever is perpendicular to the flow of fluid then shut off your pump Unscrew the knurled nut from the shut off valve leaving the valve connected to the tank Swing swivel the intake assembly towards you Look in the nut you JUST unscrewed There is a screen washer there Remove the screen and clean a...

Страница 10: ...Page 10 Exploded View Parts List LG 1500 303 5301064 Intake Detail Manifold Detail ...

Страница 11: ... Spray Height 18 20 above what is being sprayed to plant not ground Optimum Spray Height 39 Wide angle spray nozzle height is influenced by nozzle orientation The critical factor is to achieve a minimum 30 overlap Excellent spray distribution for uniform coverage along the boom Nozzle design incorporates a pre orifice to pro duce larger droplets for less drift ...

Страница 12: ...obtain warranty service under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable...

Отзывы: