WARNING:
It is recommended to wear the appropriate PPE (Personal Protective Equipment), suitable for the work to be carried out.
2. Unscrew the solution tank (1) from the machine (
Fig.1
).
3. Empty the solution tank.
N.B.:
the place designated for this operation must comply with current environmental protection regulations.
4.
When the solution tank is clean, fill it with water and reposition it in the body of the machine.
5. Switch the machine on, by pressing the main switch (2) located at the rear of the machine (
Fig.2
).
N.B.:
The main switch is in the working position when the LED inside it is on and the activation symbol is visible.
6. Activate the detergent solution delivery pump by pressing the pump control button (3) located near the handle (
Fig.2
).
7. Leave the pump active until all impurities have been removed from the water system circuit.
8.
At the end of this operation, release the button (3) and switch off the machine by pressing the switch (2).
N.B.:
The main switch is in the idle position when the LED inside it is off and the activation symbol is not visible.
9. Unscrew the solution tank (1) and empty it.
N.B.:
Rinse the inside of the tank with running water; in case of stubborn dirt, use a brush with soft bristles to remove any impurities.
10.
When the inside of the tank is clean, dry it with a microfibre cloth and refit it on the body of the machine.
11. Carry out the steps necessary to secure the machine, see paragraph “MACHINE SAFETY” on page 14.
12. With the brush head body raised, remove the pad from the support (
Fig.4
) and clean it.
N.B.:
Rinse the abrasive pad with running water; in case of stubborn dirt, use a brush with soft bristles to remove any impurities.
13.
When the abrasive pad is dry, refit it on the brush head body; see “ASSEMBLING THE ABRASIVE PAD” on page 16.
14. With the brush head body positioned on the ground, unscrew the nozzles (4) on the front part of the brush head body (
Fig.5
).
15. Immerse these in a descaling solution.
ATTENTION:
Only use descaling products; some chemical products may damage the surfaces of the parts. Carefully read the
instructions for use provided by the manufacturer of the chemical selected.
16. When the nozzles are clean, rinse them with running water.
N.B.:
Rinse the nozzles with running water; in case of stubborn dirt, use a brush with soft bristles to remove any impurities.
17.
When the nozzles are clean, dry them with a microfibre cloth and refit them on the brush head body.
DISPOSAL
Dispose of the machine in accordance with the waste disposal regulations in force in the country in
which the machine is being used.
CHOOSING AND USING THE PAD
RED PAD
Suitable for frequent use on relatively clean floors. Even cleans without water, and polishes by removing marks.
WHITE PAD
Suitable for finishing treated floors and for shiny polishing. Use dry or slightly damp.
BROWN PAD
Suitable for wet or dry scraping with wax removers. Prepare the floor for new waxing. Resistant to acids.
19