Installation instructions 

 

DANGER!

 

 

Danger of electric shock! 

 

Risk of serious or fatal injury in 

case of contact with electrical 
components. 

 

All electrical installation work must 
be carried out by a suitably qualified 
electrician. 

 

 

WARNING! 

If the system is installed by unauthorised persons 

 

Risk of injury 

 

All warranty claims are rendered invalid 

 

The plant must be installed by a suitably trained 
person! 

 

 

Provide stress relief for all pipe connections. 

 

Make sure the filter does not run dry via the pipes 
when the plant is not operating. 

 

Provide a bypass pipe if necessary. 

 

Connect the flush pipes to flush valves. 

 

Make sure the flush pipe is able to run dry. (only 
dirt side) 

 

Connect the electrical power supply according to 
the circuit diagram. 

 

Connect an electrically isolated contact to the visual 
or audible alarm device. 

 

Protect the electrical lead with a 3 x 4 A fuse. 

 

10 

Start-up 

 

DANGER! 

This automatic filter is not allowed to be put into 
operation until it has been established that the machine / 
plant in which it is to be installed complies with the 
classifications of the acceptance authority.  

 

 

DANGER! 

Danger due to high pressure in the automatic filter! 

 

Risk of injury to persons or damage to property 

 

Do not allow the flush volume / concentrate to 
spatter into the atmosphere! 

 

Make sure that: 

 

All foreign particles are removed from the 

automatic filter. 

 

All pipe connections are tightened securely. 

 

All screws are tightened. 

10.1  Functional test 

To test the pressure transmitter / differential pressure 
switch (optional) 

 

Refer to the enclosed 

manufacturer’s 

documentation. 

 

To test the functioning of the flush valve (pneumatic 
actuator) 

 

Make sure the flush lines are connected 

 

Supply compressed air to the pilot valve. 

 

Press the hand release for the pilot valve. 

 

The flush valves open. 

 

Set the hand release for the pilot valve to the OFF 
position. 

 

The flush valves close. 

 

Refer to the enclosed manufacturer’s 
documentation. 

 

 
To test the functioning of the electric actuators 

 

Refer to the Instruction Manual for the E900 filter 
controller. 

 

 

Содержание R5-3

Страница 1: ...Translation of the original instructions with installation instructions Automatic backflush filter with external medium backflushing R5 3 Mat No of original instructions 70580785...

Страница 2: ...ety instructions 2 1 Safety instructions for installation and operating personnel This Instruction Manual contains important safety instructions which must be heeded at all times during installation n...

Страница 3: ...body Solids are retained on the inner surface of the filter insert Nominal filter rating A nominated minimum percentage of the particles that are smaller than the specified rating are retained by the...

Страница 4: ...e 9 Flush nozzle 10 Switch box 11 Differential pressure switch optional 12 Gauge 13 Flush valve clean side Fig 1 Diagram of the main components R5 3 6 2 Operating principle Fig 2 Filtration principle...

Страница 5: ...et plastic optional Coating outside RAL 5005 Internals Nodular cast iron steel cast bronze GBZ Seals NBR C4400 7 2 Mounting parts Filter controller Refer to Instruction Manual complete documentation G...

Страница 6: ...l lead with a 3 x 4 A fuse 10 Start up DANGER This automatic filter is not allowed to be put into operation until it has been established that the machine plant in which it is to be installed complies...

Страница 7: ...llow concentrate to spatter into the atmosphere Always dispose of the flush volume concentrate in a manner which does not pollute the environment or process it professionally Consult the responsible a...

Страница 8: ...r insert and renew it if necessary Seals brittle Check the seals and renew them if necessary Excessive leakage at shaft seal Shaft seal defective Renew the shaft seal Shaft seal incorrectly mounted Ch...

Страница 9: ...pe is depressurised prior to opening the automatic filter Always dispose of the flush volume concentrate in a manner which does not pollute the environment Consult the responsible authorities before d...

Страница 10: ...or damage to property Make sure the pipe is depressurised prior to opening the automatic filter CAUTION Danger Be careful not to drop the nozzle Risk of injury to persons or damage to property Remove...

Страница 11: ...sh the filter insert into the housing and fix the cover 14 5 Cleaning the automatic filter Remove the filter insert refer to section 14 4 14 5 1 Cleaning the filter insert WARNING Danger of aerosol fo...

Страница 12: ...thorised persons Risk of injury All warranty claims are rendered invalid The system must be maintained by a suitably trained person Remove the filter insert refer to section 14 4 Clean the automatic f...

Страница 13: ...of the original instructions with installation instructions R5 Filtration Group GmbH 24 05 2019 Mat No 70580785 Revision 04 15 Dimension drawings 15 1 Dimension drawing of the R5 3 Fig 11 Dimension d...

Страница 14: ...Translation of the original instructions with installation instructions R5 Filtration Group GmbH 24 05 2019 Mat No 70580785 Revision 04 16 Part drawing 16 1 Part drawing R5 3 Filter Fig 12 Part drawin...

Страница 15: ...Page 15 Translation of the original instructions with installation instructions R5 Filtration Group GmbH 24 05 2019 Mat No 70580785 Revision 04 16 2 Part drawing insert Fig 13 Part drawing insert...

Страница 16: ...e 1 5 2 Insert cover 1 5 3 Insert base 1 5 4 Bush 1 5 5 Bush 1 10 Bush 1 13 Outer Nozzle 1 14 Bush 1 15 Insert guide 1 16 Nozzle bearing 1 17 Stress bush 1 18 Ring 1 19 O ring 1 31 Push on sleeve 1 33...

Страница 17: ...mended spare parts No Part name Data sheet SZ Wire cloth rating D Pressure transmitter D Diff Pressure indicator N196 M Gear motor N445 V Flush valve N198 1 5 O Ring 2 1 Gauge 5 4 Bush 5 5 Bush 10 Bus...

Страница 18: ...Page 18 Translation of the original instructions with installation instructions R5 Filtration Group GmbH 24 05 2019 Mat No 70580785 Revision 04 17 Declaration of incorporation...

Страница 19: ...Page 19 Translation of the original instructions with installation instructions R5 Filtration Group GmbH 24 05 2019 Mat No 70580785 Revision 04...

Страница 20: ...Page 20 Translation of the original instructions with installation instructions R5 Filtration Group GmbH 24 05 2019 Mat No 70580785 Revision 04...

Страница 21: ...Page 21 Translation of the original instructions with installation instructions R5 Filtration Group GmbH 24 05 2019 Mat No 70580785 Revision 04...

Страница 22: ...Page 22 Translation of the original instructions with installation instructions R5 Filtration Group GmbH 24 05 2019 Mat No 70580785 Revision 04 18 Declaration of conformity 19 Index...

Страница 23: ...tzteile 17 F Filter cake 3 Filter cartridge 4 Filter insert 5 7 9 10 11 12 Flush volume 6 7 9 Functional description 4 Functional test 6 7 8 G Gear motor 8 9 10 H Hand release 6 I Initial differential...

Страница 24: ...Filtration Group GmbH Schleifbachweg 45 D 74613 hringen Phone 49 7941 6466 0 Fax 49 7941 6466 429 fm de sales filtrationgroup com www fluid filtrationgroup com 70580785 I04 05 2019...

Отзывы: