Page 10
Translation of the original instructions with installation instructions R5- Filtration Group GmbH,, 24.05.2019, Mat. No. 70580785, Revision 04
Fig. 6:
Removing the gear motor R5-3
3
Mount in reverse order.
Connect the gear motor.
14.4 Removing the filter insert
DANGER!
The automatic filter is pressurised!
Risk of injury to persons or damage to property
Make sure the pipe is depressurised prior to
opening the automatic filter.
CAUTION!
Danger: Be careful not to drop the nozzle!
Risk of injury to persons or damage to property
Remove the filter cover together with the filter
insert without the nozzle.
Carry out the preliminary maintenance steps (refer
to section 14.2).
Remove the gear motor (refer to section 14.3).
1
Loosen the hexagon nuts on the filter cover
2
Lift out the insert together with the nozzle
Fig. 7:
Removing the inner insert from the automatic
filter