background image

Page 24 

 

Translation of the original instructions MFS-05 

Δp, Filtration Group GmbH, 16.01.18, Mat. No. 70303409, Version 03 

 

 

22 

Index  

A

 

Application ......................................................................... 4 
ATEX type key ................................................................... 3 

C

 

Characteristic selection ...................................................... 7 
Cleaning cycles ........................................................ 4, 5, 19 
Connection variants ......................................................... 13 
Cyclic switching of valve outputs ....................................... 3 

D

 

Differential pressure ......................................... 3, 4, 7, 8, 11 

E

 

Emergency shut-down ..................................................... 10 
Environmental protection ................................................... 3 

F

 

Full cycle ...................................................................... 8, 16 

I

 

Installation........................................................................ 10 
Installation work ............................................................... 10 
Interval time .................................. 4, 5, 6, 7, 8, 9, 13, 16, 19 

J

 

Jumper ........................................................... 5, 7, 8, 11, 19 

L

 

Leakage ............................................................................. 2 

M

 

Main components ............................................................... 4 
Manufacturer ...................................................................... 3 

N

 

Number of valves ............................................... 4, 5, 11, 19 

P

 

Partial cycle .................................................................... 5, 8 
Post-cleaning ............................................................ 6, 9, 16 
Pulse time ................................................................... 4, 5, 6 

R

 

Risks ................................................................................... 2 

S

 

Safety instructions .............................................................. 2 
Safety precautions ............................................................ 12 
Shut-down ........................................................................ 10 
Start-up ............................................................................. 10 

T

 

Technical data .................................................................... 6 
Test button ....................................................................... 11 
Test switch ......................................................................... 9 
Transport and storage ........................................................ 7 

W

 

Warning symbols ................................................................ 2 
Warnings ............................................................................ 2 

Z

 

Zero adjustment ................................................................. 5 

 

 

 

 

Содержание MFS-05

Страница 1: ...Translation of the original instructions Filter controller MFS 05 p Material No of Instruction Manual 70303409...

Страница 2: ...l mode 18 20 Declaration of incorporation 19 21 Declaration of conformity 20 22 Index 24 2 General safety instructions 2 1 Safety instructions for installation and operating personnel This Instruction...

Страница 3: ...lled pulsing Pulsing is activated at fixed time intervals Switching threshold Preset differential pressure that must not be exceeded or at which a defined action such as activation of a valve must tak...

Страница 4: ...ontroller has three relays for operating fault signals cleaning signals and alarm threshold exceeded 6 Main components 0 1 0 3 0 6 1 0 1 5 1 5 2 0 2 5 3 0 5 20 50 1 0 0 2 0 0 35 0 5 0 0 1 2 3 4 5 6 7...

Страница 5: ...on the motherboard On the P module Cleaning cycles 1 10 High threshold 0 40 mbar Alarm threshold 0 40 mbar Fig 5 Controls on the p module Zero The p zero adjusting screw is located to the right of the...

Страница 6: ...ment momentary contact signal Pressure measuring lines P1 pressure on dirty side upstream of filter element P1 pressure on clean side downstream of filter element Measuring hose diameter 4 mm Valve ou...

Страница 7: ...ee different modes The mode is selected by altering the assignment of terminal 16 18 and the setting of the XS1 jumper 9 1 1 Interval time control If interval time control mode is selected the control...

Страница 8: ...t threshold is exceeded Factory settings Terminal 16 17 not assigned Terminal 18 19 jumpered Jumper 3 down Full cycle optional XS1 jumper T G Cycle switch up A full cycle is executed if the switching...

Страница 9: ...ntact terminals 18 and 20 A cleaning process starts with an interval time of 8 s 9 2 3 Fault acknowledgement If a fault occurs the red fault LED lights up Find the fault Rectify the fault Acknowledge...

Страница 10: ...from interference fields The electrical connection should correspond to the connection terminal diagrams for the unit concerned All electrical wiring should be laid in accordance with the relevant EM...

Страница 11: ...ler in time control mode terminals 16 17 and 18 19 jumpered 13 2 Troubleshooting table Fault Possible cause Remedy Green operation LED not lit Power supply faulty Test the voltage Fuse F1 defective Re...

Страница 12: ...out at workplaces that are protected against electrostatic discharge During retrofitting If the unit is tampered with during the warranty period all warranty claims are rendered invalid Switch off the...

Страница 13: ...Page 13 Translation of the original instructions MFS 05 p Filtration Group GmbH 16 01 18 Mat No 70303409 Version 03 15 Appendix Connection variants 15 1 Interval time and switching threshold control...

Страница 14: ...58 59 60 61 62 63 64 65 37 38 39 40 41 66 67 68 69 70 B RS 485 PE 24 V DC 230 V DC Valve extension A Lag Discharge p Alert 25 mA Start GND DP In Release Stop Post cleaning 0 4 20 mA Output Rapid clean...

Страница 15: ...67 hex 0 1020 Not possible see program version Pulse D 68 hex 0 1020 x div 4 div 44 2 100 1000 s Interval potentiometer E 69 hex 0 1020 x div 4 div 64 10 2 s Valves F 70 hex 0 1020 x 46 92 0 5 Post c...

Страница 16: ...kinks No condensate must be allowed to accumulate on the instrument lines Provide a condensate trap if necessary No dust protection is necessary for the cleaned gas line Leaking or dirty lines can lea...

Страница 17: ...17 Translation of the original instructions MFS 05 p Filtration Group GmbH 16 01 18 Mat No 70303409 Version 03 18 Appendix Dimension drawing MFS 05 p Fig 24 Connection diagram for optional pressure sw...

Страница 18: ...reshold 18 mbar Terminal assignment See circuit diagram Jumper 18 19 Jumper settings Schw Reg jumper Up T G Cycle jumper Up 19 2 Other operating modes 19 2 1 Switching threshold mode Parameter Comment...

Страница 19: ...Page 19 Translation of the original instructions MFS 05 p Filtration Group GmbH 16 01 18 Mat No 70303409 Version 03 20 Declaration of incorporation As defined by the EC Machinery Directive...

Страница 20: ...Page 20 Translation of the original instructions MFS 05 p Filtration Group GmbH 16 01 18 Mat No 70303409 Version 03 21 Declaration of conformity...

Страница 21: ...Page 21 Translation of the original instructions MFS 05 p Filtration Group GmbH 16 01 18 Mat No 70303409 Version 03...

Страница 22: ...Page 22 Translation of the original instructions MFS 05 p Filtration Group GmbH 16 01 18 Mat No 70303409 Version 03...

Страница 23: ...Page 23 Translation of the original instructions MFS 05 p Filtration Group GmbH 16 01 18 Mat No 70303409 Version 03...

Страница 24: ...E Emergency shut down 10 Environmental protection 3 F Full cycle 8 16 I Installation 10 Installation work 10 Interval time 4 5 6 7 8 9 13 16 19 J Jumper 5 7 8 11 19 L Leakage 2 M Main components 4 Man...