Translation of the original instructions MFS-05 

Δp, Filtration Group GmbH, 16.01.18, Mat. No. 70303409, Version 03 

 

 

Contents 

1

 

Contents...................................................................... 2

 

2

 

General safety instructions ....................................... 2

 

2.1

 

Safety instructions for installation and 
operating personnel .......................................... 2

 

2.2

 

Warning structure.............................................. 2

 

2.3

 

Warning symbols used ...................................... 2

 

2.4

 

Other symbols used: ......................................... 3

 

3

 

Glossary ...................................................................... 3

 

4

 

General information ................................................... 3

 

4.1

 

Manufacturer ..................................................... 3

 

4.2

 

Information about the Instruction Manual .......... 3

 

4.3

 

ATEX type key .................................................. 3

 

5

 

Intended application .................................................. 4

 

6

 

Main components ....................................................... 4

 

6.1

 

Overview of types ............................................. 4

 

6.2

 

Controls, LEDs and displays ............................. 4

 

7

 

Technical data ............................................................ 6

 

8

 

Transport and storage ............................................... 7

 

9

 

Functions .................................................................... 7

 

9.1

 

Operating modes .............................................. 7

 

9.1.1

 

Interval time control ............................... 7

 

9.1.2

 

Switching threshold................................ 8

 

9.1.3

 

Time control ........................................... 8

 

9.2

 

Secondary functions ......................................... 9

 

9.2.1

 

Enable/stop (post-cleaning) ................... 9

 

9.2.2

 

Rapid cleaning ....................................... 9

 

9.2.3

 

Fault acknowledgement ......................... 9

 

9.2.4

 

Pressure switch ..................................... 9

 

9.2.5

 

Cleaning signal ...................................... 9

 

9.2.6

 

Alarm threshold ................................... 10

 

10

 

Installation ................................................................ 10

 

10.1

 

Unpacking ....................................................... 10

 

10.2

 

Installation procedure ...................................... 10

 

10.3

 

Electrical connection ....................................... 10

 

10.4

 

Start-up ........................................................... 10

 

11

 

Shut-down ................................................................. 10

 

12

 

Normal operation ..................................................... 11

 

13

 

Troubleshooting ....................................................... 11

 

13.1

 

Test ................................................................. 11

 

13.2

 

Troubleshooting table ..................................... 11

 

14

 

Maintenance, repair and retrofitting ....................... 12

 

15

 

Appendix: Connection variants .............................. 13

 

15.1

 

Interval time and switching threshold control .. 13

 

15.2

 

Terminal assignment ....................................... 14

 

16

 

Appendix: RS 485 serial port .................................. 15

 

17

 

Appendix: Set of instrument lines and protective 

filter (ID No. 78341984) .................................................. 16

 

18

 

Appendix: Dimension drawing MFS-

05 Δp ............ 17

 

19

 

Appendix: Default settings ...................................... 18

 

19.1

 

Main parameters of the MFS-

05 Δp in 

“interval time control” mode ............................ 18

 

19.2

 

Other operating modes ................................... 18

 

19.2.1

 

“Switching threshold” mode ................. 18

 

19.2.2

 

“Time control” mode............................. 18

 

20

 

Declaration of incorporation ................................... 19

 

21

 

Declaration of conformity ........................................ 20

 

22

 

Index .......................................................................... 24

 

 

 

General safety instructions 

2.1 

Safety instructions for installation and 
operating personnel 

This Instruction Manual contains important safety 
instructions which must be heeded at all times during 
installation, operation and maintenance. Non-observance 
can result in risks to persons and the environment as well 
as in damage to the machine or system, e.g.: 

  Failure of critical functions of the system or its 

component parts. 

  Danger to persons from electrical or mechanical effects 

as well as from chemical reactions. 

  Danger to the environment owing to the leakage of 

hazardous substances. 

 

Before installation/start-up: 

  Read the Instruction Manual carefully. 

  Make sure that installation and operating personnel are 

adequately trained. 

  Make sure that the contents of the Instruction Manual 

are fully understood by the responsible persons. 

  Define areas of responsibility and competence. 

 

During operation of the system: 

  Keep the Instruction Manual handy at the place where 

the system is used. 

  Heed the safety instructions.  

  Always operate the system/machine in accordance with 

its ratings.  

 

If in doubt: 

  Consult the manufacturer. 

 

2.2 

Warning structure 

Where possible, warnings are structured according to the 
following system: 
 

Signal word 

Possibly 

with 

symbol

 

Nature and source of the danger 

  Potential consequences of non-

observance. 

  Action to avert the danger. 

 

2.3 

Warning symbols used 

 

DANGER!

 

Immediate danger!  

  Non-observance will result in serious or fatal injury. 

 

 

WARNING! 

Potentially dangerous situation!   

  Non-observance can result in serious or fatal injury. 

 

 

CAUTION! 

Potentially dangerous situation!  

  Non-observance can result in minor or moderate 

injuries. 

 

  

CAUTION! 

Potentially dangerous situation!  

  Non-observance can result in property damage. 

 

Содержание MFS-05

Страница 1: ...Translation of the original instructions Filter controller MFS 05 p Material No of Instruction Manual 70303409...

Страница 2: ...l mode 18 20 Declaration of incorporation 19 21 Declaration of conformity 20 22 Index 24 2 General safety instructions 2 1 Safety instructions for installation and operating personnel This Instruction...

Страница 3: ...lled pulsing Pulsing is activated at fixed time intervals Switching threshold Preset differential pressure that must not be exceeded or at which a defined action such as activation of a valve must tak...

Страница 4: ...ontroller has three relays for operating fault signals cleaning signals and alarm threshold exceeded 6 Main components 0 1 0 3 0 6 1 0 1 5 1 5 2 0 2 5 3 0 5 20 50 1 0 0 2 0 0 35 0 5 0 0 1 2 3 4 5 6 7...

Страница 5: ...on the motherboard On the P module Cleaning cycles 1 10 High threshold 0 40 mbar Alarm threshold 0 40 mbar Fig 5 Controls on the p module Zero The p zero adjusting screw is located to the right of the...

Страница 6: ...ment momentary contact signal Pressure measuring lines P1 pressure on dirty side upstream of filter element P1 pressure on clean side downstream of filter element Measuring hose diameter 4 mm Valve ou...

Страница 7: ...ee different modes The mode is selected by altering the assignment of terminal 16 18 and the setting of the XS1 jumper 9 1 1 Interval time control If interval time control mode is selected the control...

Страница 8: ...t threshold is exceeded Factory settings Terminal 16 17 not assigned Terminal 18 19 jumpered Jumper 3 down Full cycle optional XS1 jumper T G Cycle switch up A full cycle is executed if the switching...

Страница 9: ...ntact terminals 18 and 20 A cleaning process starts with an interval time of 8 s 9 2 3 Fault acknowledgement If a fault occurs the red fault LED lights up Find the fault Rectify the fault Acknowledge...

Страница 10: ...from interference fields The electrical connection should correspond to the connection terminal diagrams for the unit concerned All electrical wiring should be laid in accordance with the relevant EM...

Страница 11: ...ler in time control mode terminals 16 17 and 18 19 jumpered 13 2 Troubleshooting table Fault Possible cause Remedy Green operation LED not lit Power supply faulty Test the voltage Fuse F1 defective Re...

Страница 12: ...out at workplaces that are protected against electrostatic discharge During retrofitting If the unit is tampered with during the warranty period all warranty claims are rendered invalid Switch off the...

Страница 13: ...Page 13 Translation of the original instructions MFS 05 p Filtration Group GmbH 16 01 18 Mat No 70303409 Version 03 15 Appendix Connection variants 15 1 Interval time and switching threshold control...

Страница 14: ...58 59 60 61 62 63 64 65 37 38 39 40 41 66 67 68 69 70 B RS 485 PE 24 V DC 230 V DC Valve extension A Lag Discharge p Alert 25 mA Start GND DP In Release Stop Post cleaning 0 4 20 mA Output Rapid clean...

Страница 15: ...67 hex 0 1020 Not possible see program version Pulse D 68 hex 0 1020 x div 4 div 44 2 100 1000 s Interval potentiometer E 69 hex 0 1020 x div 4 div 64 10 2 s Valves F 70 hex 0 1020 x 46 92 0 5 Post c...

Страница 16: ...kinks No condensate must be allowed to accumulate on the instrument lines Provide a condensate trap if necessary No dust protection is necessary for the cleaned gas line Leaking or dirty lines can lea...

Страница 17: ...17 Translation of the original instructions MFS 05 p Filtration Group GmbH 16 01 18 Mat No 70303409 Version 03 18 Appendix Dimension drawing MFS 05 p Fig 24 Connection diagram for optional pressure sw...

Страница 18: ...reshold 18 mbar Terminal assignment See circuit diagram Jumper 18 19 Jumper settings Schw Reg jumper Up T G Cycle jumper Up 19 2 Other operating modes 19 2 1 Switching threshold mode Parameter Comment...

Страница 19: ...Page 19 Translation of the original instructions MFS 05 p Filtration Group GmbH 16 01 18 Mat No 70303409 Version 03 20 Declaration of incorporation As defined by the EC Machinery Directive...

Страница 20: ...Page 20 Translation of the original instructions MFS 05 p Filtration Group GmbH 16 01 18 Mat No 70303409 Version 03 21 Declaration of conformity...

Страница 21: ...Page 21 Translation of the original instructions MFS 05 p Filtration Group GmbH 16 01 18 Mat No 70303409 Version 03...

Страница 22: ...Page 22 Translation of the original instructions MFS 05 p Filtration Group GmbH 16 01 18 Mat No 70303409 Version 03...

Страница 23: ...Page 23 Translation of the original instructions MFS 05 p Filtration Group GmbH 16 01 18 Mat No 70303409 Version 03...

Страница 24: ...E Emergency shut down 10 Environmental protection 3 F Full cycle 8 16 I Installation 10 Installation work 10 Interval time 4 5 6 7 8 9 13 16 19 J Jumper 5 7 8 11 19 L Leakage 2 M Main components 4 Man...

Страница 25: ...Filtration Group GmbH Schleifbachweg 45 D 74613 hringen Phone 49 7941 6466 0 Fax 49 7941 6466 429 fm de sales filtrationgroup com www filtrationgroup com 70303409 I03 01 2018...

Отзывы: