GENERAL WARNINGS: SAFETY - INSTALLATION - USE (original instructions in Italian)

CAUTION

Important safety instructions. Observe all the instructions as improper installation may cause serious damage

CAUTION

Important safety instructions. It is important to comply with these instructions to ensure personal safety. Store these 

instructions

Before commencing the installation, check the “Product technical specifications”, in particular whether this product is suitable for automating your

guided part. Should it be unsuitable, DO NOT proceed with the installation

The product cannot be used before it has been commissioned as specified in the “Testing and commissioning” chapter

CAUTION

According to the most recent European legislation, the implementation of an automation system must comply with the 

harmonised standards set forth in the Machinery Directive in force, which allow for declaring the presumed conformity 

of the automation. On account of this, all operations regarding connection to the mains electricity, as well as product 

testing, commissioning and maintenance, must be performed exclusively by a qualified and skilled technician!

Before proceeding with the product’s installation, check that all materials are in good working order and are suitable for the intended applications

The product is not intended for use by persons (including children) with reduced physical, sensory or mental capacities, nor by anyone lacking suf-

ficient experience or familiarity with the product

Children must not play with the appliance

Do not allow children to play with the control devices of the product. Keep the remote controls out of reach of children

CAUTION

In order to avoid any danger from inadvertent resetting of the thermal cut-off device, this appliance must not be powered through an 

external switching device, such as a timer, or connected to a supply that is regularly powered or switched off by the circuit

Provide a disconnection device (not supplied) in the plant’s mains power supply, with a contact opening distance that ensures complete disconnec-

tion under the conditions envisaged by Overvoltage Category III

Handle the product with care during installation, taking care to avoid crushing, knocks, falls or contact with liquids of any kind. Keep the product

away from sources of heat and open flames. Failure to observe the above can damage the product and increase the risk of danger or malfunctions.

If this should happen, stop installation immediately and contact the Customer Service

The manufacturer assumes no liability for damage to property, items or persons resulting from non-compliance with the assembly instructions. In

such cases the warranty does not cover material defects

The weighted sound pressure level of the emission A is lower than 70 dB(A)

Cleaning and maintenance to be carried out by the user must not be effected by unsupervised children

Before intervening on the system (maintenance, cleaning), always disconnect the product from the mains power supply

Check the system periodically, in particular all cables, springs and supports to detect possible imbalances, signs of wear or damage. Do not use if

repairs or adjustments are necessary, because a failure with the installation or an incorrectly balanced automated system may lead to injury

The packaging materials of the product must be disposed of in compliance with local regulations

Keep persons away from the gate when it is moved through the control elements

When performing a manoeuvre, keep an eye on the automated mechanism and keep all bystanders at a safe distance until the movement has been

completed

Do not operate the automation if anyone is working on it; disconnect the power supply before permitting any work to be carried out

INSTALLATION PRECAUTIONS

Prior to installing the drive motor, check that all mechanical components are in good working order and properly balanced, and that the automation

moves correctly

If the gate being automated has a pedestrian door, the system must include a control device inhibiting the operation of the motor when the pedestrian 

door is open

Make sure that the controls are kept at a safe distance from moving parts, while allowing a good view of these.

Unless a selector is used, the controls should be installed at least 1.5 m from the ground and must not be accessible

If the opening movement is controlled by a fire-prevention system, make sure that any windows larger than 200 mm are closed by the control ele

-

ments

Prevent and avoid any form of trapping between the moving and fixed parts during manoeuvres

Permanently affix the manual operation label next to the element enabling the manoeuvre itself

After installing the drive motor, make sure that the mechanism, protective system and all manual manoeuvres operate properly

Содержание FILO400C

Страница 1: ...r l installation et l utilisation EN Instructions and warnings for installation and use IT Istruzioni ed avvertenze per l installazione e l uso PL Instrukcje i ostrzeżenia do instalacji i użytkowania Pour portails coulissants FOR SLIDING GATES ...

Страница 2: ...200 FILO400C FILO600C CR502 B C 2 3 Step A 4 5 A B C D See Table 1 Par 3 4 Installation with rack to be mounted see Fig 4 Par 3 5 1 for the relevant procedure Installation with existing rack see Fig 5 Par 3 5 2 for the relevant procedure Step B ...

Страница 3: ...IV 40 mm 40 mm 20 30 mm 4 07 08 10 09 11 35 40 mm x 2 40 cm 02 01 03 04 06 05 40 0 50 mm mm mm mm 150 150 40 0 50 mm mm mm mm 150 150 mm 150 40 0 50 mm mm mm mm 150 150 1 2 1 2 180 ...

Страница 4: ...V 180 2 3 cm 1 2 mm 2 3 cm 15 13 17 16 14 12 PH200 Installation of photocells Fig 7 Paragraph 3 7 FL200 Installation of photocells Fig 6 Paragraph 3 6 ...

Страница 5: ...VI 20 30 mm 5 08 10 09 11 0 0 50 mm mm mm mm 150 150 12 mm 0 0 50 mm mm mm mm 150 150 12 mm mm 150 0 0 50 mm mm mm mm 150 150 12 mm 1 2 07 35 40 mm x 2 40 cm 02 03 04 06 05 1 2 01 180 ...

Страница 6: ...VII 180 2 3 cm 15 13 14 12 2 3 cm 1 2 mm PH200 FL200 Installation of photocells Fig 7 Paragraph 3 7 Installation of photocells Fig 6 Paragraph 3 6 ...

Страница 7: ...VIII 6a 6b 1 2 3 2 1 3 Fuse 1 6A T Flash ECSbus Stop Aerial SbS SbS OGI Fuse 15A L4 L3 L2 L1 PH200 1 Led SAFE 3 2 4 Ø 5 mm 01 04 02 03 05 01 02 ...

Страница 8: ...IX 7 Ø 6 mm x4 05 B Ø 6 mm x4 05 A 2 1 01 02 03 04 aerial flash 2 1 06 07 08 09 FL200 Step C ...

Страница 9: ...X 8 Step C 24 V 4 W OGI NC TX RX NO Fuse 1A T Flash ECSbus Stop Aerial SbS OGI Fuse 15A L4 L3 L2 SbS L1 led Stop led SbS led ECS 2 2 1 2 3 01 02 03 ...

Страница 10: ...ep E To PROGRAMME the system see Chapter 6 After having connected all the components of the kit and before closing the cover of the gear motor Fig 9 it is possible to connect other com ponents designed for the system optional and not present in the package ...

Страница 11: ...ISSIONING 9 7 MAINTENANCE 9 8 PRODUCT DISPOSAL 9 9 FURTHER INFORMATION 9 9 1 ADVANCED ADJUSTMENTS 10 9 1 1 Adjusting the parameters using the transmitter 10 9 1 2 Presence function 10 9 1 3 Verifying the values set for each parameter using the transmitter 10 9 2 ADDING OR REMOVING DEVICES 10 9 2 1 Memorising additional devices 10 9 3 MEMORISING ADDITIONAL TRANSMITTERS 11 9 3 1 Mode 1 memorisation ...

Страница 12: ...m sources of heat and open flames Failure to observe the above can damage the product and increase the risk of danger or malfunctions If this should happen stop installation immediately and contact the Customer Service The manufacturer assumes no liability for damage to property items or persons resulting from non compliance with the assembly instructions In such cases the warranty does not cover ...

Страница 13: ...ient space where the gearmotor is installed to allow for effecting a manual release manoeuvre Make sure that the area where the gearmotor is secured is not subject to flooding if necessary mount the gearmotor adequately raised from the ground Check that the installation surfaces of the various devices are solid for guaranteeing a stable anchorage and that they are protected and guarded against acc...

Страница 14: ...ations refer to a temperature of 20 C 3 4 PRE INSTALLATION WORKS Consult Fig 3 to define the approximate installation position of each device mounted on the system the various elements are positioned according to a standard and customary layout Get all the tools and equipment required to complete the job check that they are in good condition and that they conform to the local safety provisions Lay...

Страница 15: ...st part of the rack if it protrudes from the gate cut the part in excess Phase 15 Fig 4 The rack must not pro trude from the gate 16 Take a 2 3 cm spacer and place it in front of the mechanical stop Phase 16 Fig 4 then manually move the gate towards the mechanical stop while making it lie on the spacer When moving the gate make sure that the rack slides regularly over the pinion 17 Manually lock t...

Страница 16: ...O THE CONTROL UNIT Fig 8 01 Perforate the rubber membrane and insert the cables necessary to connect the various devices Phase 01 Fig 8 leave the cables at least 40 50 cm long and secure them with cable ties Phase 02 Fig 8 02 Connect the various devices of the kit and any other components designed for being used on the system optional and not included in the pack age Phase 03 Fig 8 It is not neces...

Страница 17: ...non conforming disconnect the power supply to the control unit and check the relevant connections of the cables Other useful information is contained in Chapters 9 9 and 10 13 Fuse 1 6A T Flash ECSbus Stop Aerial SbS OGI Fuse 15A P4 L4 P3 P2 SbS L1 P1 Aerial Fuse 15A P4 L4 P3 P2 P1 Fus SbS L1 1 T Flash Stop SbS OGI sh Stop bS OGI ECSbus 14 led SAFE TX RX 15 5 3 MEMORISATION OF CONNECTED DEVICES On...

Страница 18: ...use 1 6A T Flash ECSbus Aerial Fuse 15A P4 L 4 L4 L3 L2 P2 3 L2 P2 SbS L1 P1 18 Fuse 1 6A T Flash ECSbus Stop Aerial SbS OGI Fuse 15A L4 L3 L2 SbS L1 Fuse 1 6A T Flash ECSbus Stop Aerial SbS OGI Fuse 15A L4 L3 L2 SbS L1 19 03 Lastly perform various opening and closing manoeuvres while checking that the gate leaf stops at least 2 3 cm from the mechanical stops during both the opening and closing ph...

Страница 19: ...a Fig 24 Fuse 1 6A T Flash ECSbus Stop Aerial Fuse 15A P4 L4 L3 L2 P3 P2 SbS L1 P1 Fuse 1 6A T Flash ECSbus A Fuse 15A Stop Aerial al Sb P4 L4 L3 L2 P3 P2 SbS L1 P1 4 L4 L3 L2 P3 P2 SbS L1 P1 23 Fuse 1 6A T Flash ECSbus Stop Aerial SbS OGI Fuse 15A P4 L4 L3 L2 P3 P2 SbS L1 P1 Fuse 1 6A T Flash ECSbus Stop SbS OGI Fuse 15A bS 1 S Sb L L1 P P1 P4 L4 L3 L2 P3 P2 P4 L4 L3 L2 P3 P2 24 semi automatic au...

Страница 20: ...ly inverts the direction of movement SbS Function sequence of gate movements associated with the Step by Step SbS command OGI Open Gate Indicator function output to which it is possible to connect a 24 V maximum 4 W warning light The adjustment can be effected by means of any transmitter memorised in Mode 1 as those supplied see Paragraph 9 3 1 If there is no transmitter memorised in Mode 1 it is ...

Страница 21: ... light remains lit for 5 seconds then switches off and follows the gate s behaviour when closed If the OGI function is active the lamp connected to it behaves in the following way off automation in fully closed position slow flashing execution of the opening manoeuvre fast flashing execution of the closing manoeuvre steady lit automation in fully open position 9 1 3 Verifying the values set for ea...

Страница 22: ...r 9 4 02 In Table 5 choose the command and the number of press down actions to be effected on the desired transmitter key 03 On the control unit Fig 28 press and release button P4 for a number of times corresponding to the chosen command Table 5 led L4 must emit a number of fast flashes corresponding to the chosen command 04 Within 10 seconds press and hold for 2 seconds the key of the transmitter...

Страница 23: ...ed 9 5 COMPLETE DELETION OF THE RADIO MEMORY This procedure allows for cancelling ALL memorised transmitters the procedure must be carried out on the control unit before proceeding open the cover of the gearmotor Fig 9 01 On the control unit Fig 28 press and hold button P4 02 Check that led L4 lights up for 4 5 seconds that it switches off then flashes 3 times 03 Precisely at the 3rd flash release...

Страница 24: ...eck that the voltage on the photocell terminals is around 8 12 VDC if the volt age is correct the photocell is probably faulty 3 quick flashes and 1 second pause Device not recognised by the control unit Repeat the recognition procedure on the control unit Check that all pairs of pho tocells on the ECSBus have different addresses consult the instruction manual of the photocells 1 very slow flash T...

Страница 25: ...is locked Release the automation by sending an automation release command to the con trol unit 9 10 3 Control unit signals On the control unit there are LEDs Fig 8 that emit signals both during normal operation and in case of anomalies see Table 8 TABLE 8 Led ECSBus Status Action Off Fault Verify whether there is power and whether the fuses are blown in this case iden tify the reason for the failu...

Страница 26: ... can be connected in parallel to each other without any quantity limit Note 3 multiple NC devices can be connected in series to each other without any quantity limit Note 4 only 2 devices with 8 2 kΩ constant resistance output can be connected in parallel if required multiple devices must be connected in cascade mode with a single 8 2 kΩ termination resistance 2 nd type device 1st type device NO N...

Страница 27: ...e of the fault and replace them with others of the same type see Fig 33 fuse 3 15A T fuse 1A T 33 The manoeuvre fails to start and the auto mation s flashing light is off Check that the command is actually received If the command reaches the SbS input the rel evant SbS Led lights up if a transmitter is used the ECSBus Led must emit 2 long flashes The manoeuvre fails to start and the auto mation s ...

Страница 28: ... a power outage a back up battery can be used model PR100 not supplied see Chapter 9 Further information or the relevant instruction manual In the event of a gearmotor fault it is still possible to try release the motor to check whether the fault lies in the release mechanism 180 180 11 3 User admissible maintenance operations The operations that the user must carry out periodically are listed bel...

Страница 29: ... com Service Après Vente France En cas de panne merci de contacter obligatoirement notre Service Après Vente par téléphone ou par email 0 820 859 203 Service 0 15 min prix appel niceservice niceforyou com Merci de ne pas retourner le produit en magasin Worldwide Customer Service customerservice niceforyou com ...

Отзывы: