background image

Specifications

CCT Range

Light Engine

Power Draw

DC Input

AC Input

Power Port

DMX Ports

Weight

Size (L x W x H)

Mount

Thermal Design

Operating Temperature

IP Rating

LED Lifetime

Certifications

2800 - 6500K Continuous Tuning

Dense Matrix LED

90W Max

12 - 30V (80W DC Max)

100 - 240V AC, 50 ~ 60Hz

2.5mm DC Jack

TRRS (In & Out) *Pro and Pro Plus models only*

1.9lbs / 0.8kg

5.9in x 4.7in x 8.1in / 15.0cm x 11.9cm x 20.6cm 

Baby Stud 5/8” Female (16mm)

Advanced Vapor Cooling System (Fan Cooled)

32 - 104ºF / 0 - 40ºC

IP-24

42,000 hours

CE, UL, FCC

Assigning DMX Address:

Rear Panel Interface & Operation

Knob

CCT

PWR

HUE

DMX

Range

2800K - 6500K

100% - 0.1%

± 0.25 Magenta/Green

1 - 510

Function

Set color temperature

Set intensity

Set HUE value

Set DMX address

1. Double click the DMX Address Knob (7) to display the DMX 

address setting screen on the OLED Display (15). 

2. Rotate the knob to select the desired base address (1-510).
3. Once desired address is displayed on the screen, lock in the setting 

by clicking the knob once. Alternatively, the address will automati-
cally lock in after 1 second of inactivity.

4. When a DMX address is selected, the fixture will automatically 

assign the next one/two addresses in the following order: 

    • Pro Plus: (1) Intensity (2) CCT (3) Hue

• Pro: (1) Intensity (2) CCT

P360 Pro Plus 

P360 Pro

• For adjusting the fixture’s DMX address via RDM, consult the 
   operating instructions for DMX/RDM control systems.