Specifications
CCT Range
Light Engine
Power Draw
DC Input
AC Input
Power Port
DMX Ports
Weight
Size (L x W x H)
Mount
Thermal Design
Operating Temperature
IP Rating
LED Lifetime
Certifications
2800 - 6500K Continuous Tuning
Dense Matrix LED
90W Max
12 - 30V (80W DC Max)
100 - 240V AC, 50 ~ 60Hz
2.5mm DC Jack
TRRS (In & Out) *Pro and Pro Plus models only*
1.9lbs / 0.8kg
5.9in x 4.7in x 8.1in / 15.0cm x 11.9cm x 20.6cm
Baby Stud 5/8” Female (16mm)
Advanced Vapor Cooling System (Fan Cooled)
32 - 104ºF / 0 - 40ºC
IP-24
42,000 hours
CE, UL, FCC
Assigning DMX Address:
Rear Panel Interface & Operation
Knob
CCT
PWR
HUE
DMX
Range
2800K - 6500K
100% - 0.1%
± 0.25 Magenta/Green
1 - 510
Function
Set color temperature
Set intensity
Set HUE value
Set DMX address
1. Double click the DMX Address Knob (7) to display the DMX
address setting screen on the OLED Display (15).
2. Rotate the knob to select the desired base address (1-510).
3. Once desired address is displayed on the screen, lock in the setting
by clicking the knob once. Alternatively, the address will automati-
cally lock in after 1 second of inactivity.
4. When a DMX address is selected, the fixture will automatically
assign the next one/two addresses in the following order:
• Pro Plus: (1) Intensity (2) CCT (3) Hue
• Pro: (1) Intensity (2) CCT
P360 Pro Plus
P360 Pro
• For adjusting the fixture’s DMX address via RDM, consult the
operating instructions for DMX/RDM control systems.
Содержание P360 GEen II Series
Страница 1: ...190102A2...
Страница 5: ......