background image

 

 

 
 

SUPPLEMENTARY OPERATING MANUAL 

 

 

1

-

1

 

 

 

02-11-05

 CDP-01 

Figure Sheet 1-811-B

 

 

 

GENERAL INTRODUCTION 

 

 
 
 
 

Application Description 

 
 
Application is a Recoiler using the SE-34 Sensor.  Linear analog position feedback is used on the 
mandrel.  The mandrel to sensor bandwidth ratio is programmable. The CDP-01 can be operated 
from the keypad (internal control) or via the parallel port (external control).  When placed in 
automatic mode, the sensor output signal and the mandrel position are recorded.  The sensor 
continues to monitor the web edge and the mandrel, then follows the sensor output signal. 
 
A CDP-01-H12 or CDP-01-M12 is required for this application. 

 
 
 
 

Software Part Numbers 

 
 
The software part numbers are located on the side of the CDP-01 housing. They include the 
Matrix Setup no. (MS), State Machine no. (SM) and firmware version ( Dx ).  
 
 
CDP version: CDP-01-H12 

D1:5650xx-02x    MS: 100055-02x 

Please quote these 

 

     or CDP-01-M12 

D2:5650xx-02x    SM: 100056-02x 

details with all inquiries. 

    D3:5650xx-02x 

 

 

FIFE 

USA 

 
 

 
 

Connecting the System Components 

 
 
The system components are to be connected according to the Cable Connection Diagram 
contained in the documentation. 
 
 

Содержание CDP-01

Страница 1: ...02 11 05 CDP 01 Figure Sheet 1 811 B CDP 01 Additional Instruction Manual Recoiler Application With Sensor Selection Using SE 34 Sensor ...

Страница 2: ...02 11 05 CDP 01 Figure Sheet 1 811 B ...

Страница 3: ...n of this Additional Instruction Manual in any form in whole or in part requires the prior written consent of FIFE The information given in this Additional Instruction Manual is subject to change without notice We have compiled this Additional Instruction Manual with the greatest possible care and attention however the possibility of error can not be completely excluded FIFE accepts no legal liabi...

Страница 4: ...02 11 05 CDP 01 Figure Sheet 1 811 B ...

Страница 5: ...OVERVIEW OF FUNCTION 2 OPERATOR CONTROL OPTIONS 2 1 SPECIAL FEATURES OF EXTERNAL CONTROL 2 1 INPUT MATRIX EXTERNAL CONTROL 2 2 EXPLANATION OF THE OPERATING MODES 2 3 to 2 4 EXPLANATION OF THE SENSOR MODES 2 5 START UP POSITION TRANSDUCER CALIBRATION 2 6 START UP SENSOR BANDWIDTH TO MANDREL RATIO CALIBRATION 2 7 START UP MANDREL DRIVE POLARITY 2 8 TROUBLESHOOTING 3 FAULT DIAGNOSIS FAULT RECTIFICATI...

Страница 6: ...02 11 05 CDP 01 Figure Sheet 1 811 B ...

Страница 7: ...on are recorded The sensor continues to monitor the web edge and the mandrel then follows the sensor output signal A CDP 01 H12 or CDP 01 M12 is required for this application Software Part Numbers The software part numbers are located on the side of the CDP 01 housing They include the Matrix Setup no MS State Machine no SM and firmware version Dx CDP version CDP 01 H12 D1 5650xx 02x MS 100055 02x ...

Страница 8: ...02 11 05 CDP 01 Figure Sheet 1 811 B ...

Страница 9: ...ogrammable logic controller The symbols below are used for the various operator control options in the following Internal operation External operation Special Features of External Control When the operation modes are being controlled via external control the Automatic Servo Center Manual keys of the CDP 01 control panel are disabled If the cable to the parallel port X7 of the CDP 01 is disconnecte...

Страница 10: ... External Control Inputs CDP 01 Modes I5 I4 I3 I2 I1 I0 External Lock H Automatic with Center Guiding H H L Automatic with Edge L Sensor H L H Automatic with Edge R Sensor H L L Manual L L H Center Mandrel L H L Jog Mandrel Left L H H Jog Mandrel Right H L H L Low level H High level any ...

Страница 11: ...d MANUAL Manual Select Manual via external control The active drives are switched to Manual Check LED 3 lit Sensor mode selection and setup functions can be performed if desired Left Right Press the or key to set Left or Right to manually alter the position of the drive JOG MANDREL LEFT RIGHT Select Jog Mandrel Left or Jog Mandrel Right via external control to manually alter the position of the ma...

Страница 12: ... The mandrel now follows the sensor output signal System gain can be altered if desired Guide point shifts are not allowed in this application Reference CDP 01 Reference Manual Basic Settings section EXTERNAL LOCK External Lock Set External Lock via external control Note Automatic guiding is suspended as long as External Lock is present on the parallel port CENTER MANDREL Center Mandrel Select Cen...

Страница 13: ...SE 34 sensor signal and the mandrel position transducer signal are combined EDGE CENTER Select this sensor mode while in Manual mode for center guiding to both the Edge 1 and Edge 2 outputs of the SE 34 sensor The SE 34 sensor signals and the mandrel position transducer signal are combined SPECIAL Select this sensor mode while in Manual mode to view the Edge 2 output of the SE 34 sensor SPECIAL Se...

Страница 14: ...irection of the end of the SE 34 sensor which is opposite of the junction box end Press the Setup key Press the Sensor key Press the F1 key Check LED 4 lit Press and hold the Left or Right Jog key until the mandrel is located at the end of the stroke in the direction of the junction box end of the SE 34 sensor Press the F2 key Check LED 5 lit The LED bar graph indicates contrast If the contrast is...

Страница 15: ...e point of the scan Make a mark here From this point move the edge of a web into the sensor towards the junction box a distance equal to the total stroke length of the mandrel This procedure is simplified by making a calibration strip cut to the same width as the guide cylinder s stroke The strip should be kept for future calibrations With the web edge stable at this position press and hold the F2...

Страница 16: ...nnect the parallel cable and select Automatic with Edge R Sensor via external control Move the web momentarily back and forth in the sensor field of view If the mandrel stops moving when the web is not moving repeat this portion of the procedure for Edge L and Edge Center sensor modes with the web placed in the corresponding sensor s field of view then skip the rest of this portion of the procedur...

Страница 17: ...e Guide Direction Fault In Servo Center mode the mandrel moves to either end of the stroke instead of to the center of its stroke Remedy Select Manual mode and change the servo center polarity Reference CDP 01 Reference Manual section Servo Center Polarity Fault In Automatic mode the mandrel does not accurately follow the sensor Remedy Perform the procedure Start up Sensor Bandwidth To Mandrel Rat...

Страница 18: ...02 11 05 CDP 01 Figure Sheet 1 811 B ...

Отзывы: