![Fiessler BLCT Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/fiessler/blct/blct_operating-manual_2288060009.webp)
9
1
System description
1.7
Technical data
Technical data
Characteristic data
ULCT… / BLCT…
Safety category
Protective field height
Type 4 according to EN 954-1 and IEC 61496 Part 1 + Part 2 or EN 61496 Part 1 + Part 2;
deployable to SIL 3 (EN 61508)
1
; category 4 PL e (ISO 13849-1)
1
100 mm … 1500 mm
Protective field width
(max. range)
Resolution
Reaction time
Self-diagnosis
0 … 5 m
Smallest detectable obstruction size of 14 mm or 30 mm
4 ms to 29 ms depending on the length and type; correspondingly short safety clearances
Microcontroller monitoring of safety functions (self-monitoring)
7-segment fault display
Operating modes
(programmable without
a PC, Page 7)
Mechanical data
Mountings
Housing design
- With / without restart interlock
- With / without contactor control (EDM)
- Pivot-joint holder on the light barrier's upper and lower sides for fine adjustment
- Movable shackles with adjustment screws on the housing's rear (optional)
- Flexible T-slot (optional)
Aluminium profile, 25 x 35 mm, plastic coating, RAL 1021 (yellow).
End-pieces comprise acid-resistant plastic (polyamide) reinforced with glass beads.
Plexiglass for light entry and exit.
Operating data
Protection type
Protection class
IP 65
III
Ambient operating
temperature
Storage temperature
-10 to 50 °C
-25 to 70 °C
Electrical data
Transmitter ULCT-S
Receiver ULCT-E / BLCT-E
Supply voltage
2
Current consumption
24 V DC + 20 % - 15 % SELF, PELF
Max. 250 mA
24 V DC ± 20% SELF, PELF
Max. 250 mA (without load)
Outputs
Inputs
Electrical connection
-
-
OSSD 1 and 2: Fail-safe PNP outputs with short-circuit and
cross-connection monitoring.
Output current: min. 0 mA: max. 0.5 A
Max. output current in the inactive state: 50
µ
A
Max. voltage in the inactive state: 0.9 V
Max. capacitive load: 1
µ
F
Contactor control (EDM) and start button
0 V to 24 V DC ± 20 %, max. 5 mA
M12 plug connector, 4-pole
M12 plug connector, 8-pole
Table of Contents
1
Contact us directly for details on how to precisely tailor systems to your requirements.
2
The external voltage supply must be capable of bridging brief mains failures of up to 20 ms according to EN 60 204-1.
We offer suitable power supply units as accessories.
FIESSLER
E L E K T R O N I K
Fiessler Elektronik GmbH & Co. KG
Telefon: +49 (0) 711 / 91 96 97-0 Internet: http://www.fiessler.de
Telefax: +49 (0) 711 / 91 96 97-50 eMail: [email protected]
Doku Nr. 1121 Stand 08.01. 2018 RK/Aui