![Fiessler BLCT Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/fiessler/blct/blct_operating-manual_2288060014.webp)
14
2
Assembly
2.3
Installation conditions
Table of Contents
FIESSLER
E L E K T R O N I K
max. 5o
a
max. 5o
Distance to reflective surfaces
The minimum clearance a is listed
in the adjacent table.
Installation range in m
To 3
4
5
6
Clearance a in mm
130
175
219
262
Fig. 14/1: Clearance to reflective surfaces
Hazard zone
Reflective object
(e.g. container)
ULCT receiver
ULCT transmitter
Direction of approach
Interrupted beam
Central beam
Container
To prevent reflective objects
from hindering a clear view
and detection of obstruc-
tions, ULCT/ BLCT safety
light curtains must be mounted at a
minimum clearance a
(Figure 14/1)
from
such reflective objects.
Table 14/2: Installation range / clearance
Fiessler Elektronik GmbH & Co. KG
Telefon: +49 (0) 711 / 91 96 97-0 Internet: http://www.fiessler.de
Telefax: +49 (0) 711 / 91 96 97-50 eMail: [email protected]
Doku Nr. 1121 Stand 08.01. 2018 RK/Aui