Warnings issued when several consecutive malfunctions occur that lead to an interlocking of the AKAS@
with displayed error reports. The interlocking status can be cancelled only by a voltage reset.
Electrical connections - Description / Wiring diagrams
Displaying outputs
50
Warnings (binary xxxxxx10)
error reports (binary xxxxxx01)
6
6.6
Warning
transferred
decim. byte
error
transferred
decim.byte
operating mode description
possible text in the display
system
reason for the error
6
6
5
5
no monitoring of the
protective circuit
EDM does not respond
even though the OSSDs
are released
-
If this happens during fast sped: valve position moni-
tors do not switch in fast speed position or at an in-
terruption in the EDMS circuit.
If this happens during Muting: EDMS and EDMO
are both at + 24 V
-
10
10
18
18
9
9
with additional sa-
fety PLC
(e.g.
FPSC
}
17
17
overrun traverse
control
slow speed signal error
slow speed signal error
When switching over from fast speed into slow
speed, at SGO 24 V
When swithcing over vom fast speed into slow
speed, the triggereing of the SGS and the SGO is
antivalent instead of equivalent
machine stops at the over-
run traverse cam/ cam
switch does not conduct
-
in the case of "warning": open press completey, in
the case of "error": check cable and cam switch
-
30
86
86
90 / 102
29
85
85
89 / 101
no monitoring of the
protective circuit
106
106
114
126
105
105
with additional sa-
fety PLC
(e.g.
FPSC
}
113
125
no complete slow speed
position in the Muting sta-
tus
Problem release of the rear
stoppers
This message is displayed when the stroke is star-
ted in slow speed range or with a slow speed re-
quest SGA = 0 and if there is no complete switch-
over of the slow speed position monitors into slow
speed. Check the SGA line for interruptions and
check also the slow speed position monitors and
their lines.
line short circuiting of one RXOX circuit with another
line
internal error
Problem fast speed -- slow
speed request
if this is displayed again after the voltage reset, a ve-
rification by Fiessler Elektronik is necessary
line short circuiting of the SGA circuit with another li-
ne
fast speed/slow speed
signals are faulty in stop
status
fast speed/slow speed
signals are faulty in stop
status
during operation without safety PLC, both EDMS
and EDMO are at + 24 V at the same time in stop-
ped status.
The triggering of the SGS and the SGO is antivalent
instead of equivalent
OSSD- error
short circuit of the the mu-
ting lamp line
line short circuiting of the OSSD circuits with other li-
nes
only possible at the version with external Muting
lamp, otherwise: internal problem
130
142
150
166
129
141
149
165
170
198
interlocking
without prior
warning
interlocking
without prior
warning
169
197
201
237
with additional sa-
fety PLC
(e.g.
FPSC
}
problem at request for hig-
her switchover point:
Muting lamp should not
light up, release box ben-
ding button
line short circuiting of the HUSP circuit with other li-
nes
short circuit in box bending button or line short circui-
ting of the KAST circuit with other lines
problem at pressing of foot
pedal
Hex switches deadjusted
line short circuiting of the foot pedal circuits FUO
and FUS with other lines
Readjust the Hex switches onto the selected opera-
ting mode, then carry out a voltage reset. If the error
repeats itself, a repair by Fiessler Elektronik is ne-
cessary.
invalid Hex switch position
external transmitter signals
are received
Turn HEX switch into a permitted position
The transmitter is triggered although the foot pedal is
released, or a transmitter from another AKAS® fo-
cuses the receiver. This must be prevented by ade-
quate constructional measures.
unequal slow speed con-
nections
disable key switch - volta-
ge reset
This error happens only during the operating mode
"for connection to safety PLC" if the signals at the
SGO and the SGS are not exactly the same.
The key switch ot the front reset switch have been
activated when the foot pedal was pressed, or there
is an error within the foot pedal, or the front reset
button does not close.
246
245
internal error
If this message is displayed immediately after a vol-
tage reset, there is an EMC problem or an internal
failure of the appliance.
Doku Nr. 988 Stand 3.2.2016 / Aui
background grey:
other message or
no message, if mo-
nitoring functions
are partially cancel-
led
FIESSLER
E L E K T R O N I K