1. For electrical testing, connect test leads to black
"COM" and red "+" jacks.
2. Rotate the dial to your desired measurement.
3. Connect to test points and read measurement.
4. For temperature testing, remove test leads, slide
TEMP switch to the right and connect a Type K
thermocouple.
Certifications
UL 61010-1, Third Edition
EN61010-1, EN61010-2-032
EN61010-2-033, EMC EN61326-1
FCC ID: VEARF915A
C-Tick (N22675)
WEEE
CATIII 600V, class II and pollution degree 2 indoor
use comply with CE, RoHS compliant.
CATIII is designated for measurements performed
in the building installation.
Specifications
Display:
10000 count dual display
Backlight:
5 minute duration with auto-off. Blue color
Overrange:
(OL) or (-OL) is displayed
Measurement rate:
3.3 times per second, nominal
Zero:
Automatic
Operating environment:
32°F to 122°F (0°C to 50°C) at <70%RH
Storage temperature:
-4°F to 140°F (-20°C to 60°C), 0 to 80%RH (with
battery removed)
Accuracy:
Stated accuracy @ 73°F±9°F (23°C±5°C), <75%RH
Temperature coefficient:
0.1 x (specified accuracy) per °C [0°C to 19°C
(32°F to 66°F), 28°C to 50° C (82°F to 122°F)]
APO (Auto Power Off):
Approx. 30 minutes
Power:
Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22
Battery life:
100 hours typical alkaline
Low battery indication:
Battery icon blinks and "batt" is displayed
when the battery voltage drops below the operating level
Dimensions:
233mm(H) x 79mm(W) x 48mm(D)
Weight:
Approx. 315g including battery
Altitude:
Up to 6562 ft (2000m)
Overload protection:
600VDC or 600VAC rms unless otherwise stated
Test leads:
Use UL listed test leads that comply to UL61010-031 rated
CATIII 600V or above. Included test leads are gold-plated and have
removable safety caps.
Please operate the instrument following all instructions of
the operator's manual to avoid impairing the safety of
the product.