Fieldpiece Job Link SC480 Скачать руководство пользователя страница 16

31

30

Functions

Auto Power Off

Auto power off or APO will automatically turn off 

your meter after 30 minutes of inactivty. By default 

it is activated and APO will show on the display. To 
disable, turn meter off. Hold 

TRUE RMS

AUTO OFF

TYPE K

30V MAX

T1

L1

L2

L3

T2

Sync

OFF

Range

Select

H/M/m

SC660

ZER

O A

DC

°F °C

TEMP

CAT III

600V

COM

INRUSH

 and power on 

the meter by turning the selector dial to any range. 
Release 

TRUE RMS

AUTO OFF

TYPE K

30V MAX

T1

L1

L2

L3

T2

Sync

OFF

Range

Select

H/M/m

SC660

ZER

O A

DC

°F °C

TEMP

CAT III

600V

COM

INRUSH

 after the beep. APO will no longer 

display over the battery icon.

Hold/Max/min

Press 

TRUE RMS

AUTO OFF

TYPE K

30V MAX

T1

L1

L2

L3

T2

Sync

OFF

Range

Select

H/M/m

SC660

ZER

O A

DC

°F °C

TEMP

CAT III

600V

COM

INRUSH

 to cycle through Hold, Maximum, 

minimum, or real-time measurements. When 

MAXMIN is displayed, you are seeing the real-time 

measurement, but Max and min values are still 
being recorded. Press 

TRUE RMS

AUTO OFF

TYPE K

30V MAX

T1

L1

L2

L3

T2

Sync

OFF

Range

Select

H/M/m

SC660

ZER

O A

DC

°F °C

TEMP

CAT III

600V

COM

INRUSH

for 1 second to clear 

and exit. Press 

TRUE RMS

AUTO OFF

TYPE K

30V MAX

T1

L1

L2

L3

T2

Sync

OFF

Range

Select

H/M/m

SC660

ZER

O A

DC

°F °C

TEMP

CAT III

600V

COM

INRUSH

to log an SC480 measurement 

in Job Link mobile app. See Wireless Section for Job 

Link compatibility details.

High Voltage Warning

The  symbol will display when measuring 

>30VAC/VDC. An audible beep will be heard and 

red LED will be shown.

Battery Replacement

When your meter’s battery is low, the battery icon 

will appear empty and blink for 30 seconds. “bAtt” 

will display and meter will power off. 

Turn dial to OFF position, disconnect test leads 

and remove the battery cover with magnet strap 

on the back of your meter. Remove old battery and 

replace with a standard 9V battery only. Be sure to 

re-insert the magnet strap before re-installing the 

battery cover.

Backlight Illumination

See your measurements in dark environments. 

Press 

TRUE RMS

AUTO OFF

TYPE K

30V MAX

T1

L1

L2

L3

T2

Sync

OFF

Range

Select

H/M/m

SC660

ZER

O A

DC

°F °C

TEMP

CAT III

600V

COM

INRUSH

 to illuminate the display. Illumination 

will stay on for 5 minutes before turning off 

automatically. Illumination can be turned off at any 
time by pressing 

TRUE RMS

AUTO OFF

TYPE K

30V MAX

T1

L1

L2

L3

T2

Sync

OFF

Range

Select

H/M/m

SC660

ZER

O A

DC

°F °C

TEMP

CAT III

600V

COM

INRUSH

.

Manual Ranging

Press 

TRUE RMS

AUTO OFF

TYPE K

30V MAX

T1

L1

L2

L3

T2

Sync

OFF

Range

Select

H/M/m

SC660

ZER

O A

DC

°F °C

TEMP

CAT III

600V

COM

INRUSH

 to disable auto-ranging and set your 

clamp meter to a specific range. Manual ranging 

applies to VAC, VDC, MFD, W and resistance (Ω). 

Press for 1 second to exit manual ranging and return 

to auto-ranging.

Содержание Job Link SC480

Страница 1: ...1 Fieldpiece Job Link System Power Clamp Meter OPERATOR S MANUAL Model SC480 ...

Страница 2: ... generated from frequencies above 1000Hz as the low pass filter limits voltage measurements to below 1000Hz Do not use during electrical storms or in wet weather Do not use around explosive gas dust or vapor Do not apply more than the rated voltage to as marked on the meter between terminals or between any terminal and earth ground Donotusewithoutthebatteryandthebackcase properly installed Replace...

Страница 3: ...ensure proper operation Usetheproperterminals functionsandrangefor your measurements Never ground yourself when taking electrical measurements Connect the black common lead to ground or neutral before applying the red test lead to potential voltage Disconnect the red test lead from the voltage first Always work with a partner Keep fingers behind the finger guards on the probes All voltage tests Al...

Страница 4: ...se voltage lines with just two leads Capture L1L2 and L1L3 to check that motor lines are correctly installed with Phase Rotation test Take more accurate VAC and AAC readings on variable frequency drives with True RMS sensing technology Measure the starting amp draw of a compressor with Inrush current mode IlluminatethewaywithapowerfulLEDbuiltinto the clamp jaw Easily see your measurements with the...

Страница 5: ...for HVACR professionals Select the parameter on the dial you want to measure with the rotating selector switch TRUE RMS AUTO OFF TYPE K 30V MAX T1 L1 L2 L3 T2 Sync Range Select H M m SC660 ZERO ADC F C TEMP CAT III 600V COM TRUE RMS AUTO OFF TYPE K 30V MAX T1 T2 S y n c OFF Range Select H M m SC660 Z E R O A D C F C INRUSH TRUE RMS AUTO OFF TYPE K 30V MAX T1 L1 L2 L3 T2 Sync OFF Range Select H M m...

Страница 6: ... Celsius ContinuityTest DiodeTest Frequency Hertz ResistanceTest Ohms CapacitanceTest farads Microamps DC Nano Unit 10 9 one billionth Micro Unit 10 6 one millionth Milli Unit 10 3 one thousandth Kilo Unit 103 one thousand Mega Unit 106 one million Alternating Current Direct Current Easy to Read Display Easily see your measurements on the big dual display You ll never miss a reading no matter the ...

Страница 7: ...otection 1000VDC or 750VAC rms Volts DC VDC SelectVDC and measure DC voltages on circuit boards on more advanced HVACR systems and logic control boards Ranges 1000mV 10V 100V 1000V Resolution 0 1mV Accuracy 0 5 5 Input Impedance 5MΩ Overload Protection 1000VDC or 750VAC rms Non ContactVoltage NCV Use NCV to check 24VAC from a thermostat or live voltage up to 600VAC Always test a known live source ...

Страница 8: ...C Frequency Hz through the clamp and Inrush AAC current is measured in theVAC AAC Hz switch position shown above Inrush AAC Current Inrush mode captures the starting amp draw of a motor Starting amp draw can assist in diagnosing a motor before it fails Activate Inrush mode 1 Rotate selector switch toVAC AAC Hz 2 PressSELECToncetoshowAAConupperdisplay PressINRUSHonthe rightsideofmetertoactivateInru...

Страница 9: ...uracy 1 0 5 Volts burden 5V Overload Protection 600VDC or 600VAC rms Capacitance MFD Testmotorstartandruncapacitors Capacitorsareoneofthemost failurepronecomponentsinaHVACRsystem Disconnectfrompowerand anyresistorsfoundbetweenterminals Discharge capacitor before testing If dIS C is displayed the capacitor needs to be fully discharged to test Press SELECT three times to enter Capacitance mode Range...

Страница 10: ...0V TEMP K TYPE 30V MAX SEL Perfect for checking isolated fuses use the continuity function to test whether a circuit is open no beep no green LED or closed beep and green LED Press SELECT once to enter Continuity mode Range 100Ω Resolution 0 01Ω Response time 100ms Audible beep 30Ω Visual Indicator Green LED Overload Protection 600VDC or 600VAC rms DiodeTest O O F F F F MFD NCV V AC VDC AAC Hz Hz ...

Страница 11: ...he particularT C that is plugged into it Though it s possible for a calibration to hold for years it s best practice to calibrate regularly if only to verify accuracy Labelling yourT C T1 orT2 will help ensure using the sameT C forT1 andT2 ports Calibration is quick and easy requiring just a known temperature to calibrate to Ice water is probably the most accurate and readily available known tempe...

Страница 12: ...h voltage and amperage simultaneously Connect test leads to main power supply terminals and secure amp clamp around the same line that the positive red test lead is connected to See Power Factor in top display and Power in bottom display Press SELECT to toggle Active Power W Reactive Power VAr Apparent Power VA CAUTION DO NOT MEASUREVOLTAGE LINES OR EXPOSETHE METERTO LIVE POWER LINES EXCEEDING 750...

Страница 13: ... port and red test lead to theVΩ L2 L3 port on the SC480 You will see L1L2 blinking to indicate phase rotation test is ready to begin Step 2 Connect Leads Connect both black and red test leads to any two of the three phase voltage lines in question The line voltage will hold on the bottom display Blinking L1 and L2 disappear L3 will blink on top display to indicate test is ready for Step 2 Importa...

Страница 14: ...e sure voltage lines arewithin50 80Hztoperformthephaserotation test Modular Expandability Your SC480 is compatible with all Fieldpiece Accessory Heads WithFieldpiece Accessory Heads youcanmeasureanyavailableparameter andread the measurement on your new meter s display in real time Hold Max and min Rotate the selector toVDC and stay in mV range Remove the probe tips of your test leads and connectyo...

Страница 15: ...iece com for all Job Link System options Wireless Mode Send electrical measurements wirelessly from SC480 directly to the Job Link mobile app No JL2 transmitter required Sending Wireless Measurements 1 Select any switch position other than L1L2 and NCV on SC480 2 Press WIRELESS ON OFF button on meter 3 Favorite your SC480 by going to the measurement screen in the Job Link app 4 Tap on Electrical t...

Страница 16: ...SC480 measurement in Job Link mobile app SeeWireless Section for Job Link compatibility details HighVoltageWarning The symbol will display when measuring 30VAC VDC An audible beep will be heard and red LED will be shown Battery Replacement Whenyourmeter sbatteryislow thebatteryicon will appear empty and blink for 30 seconds bAtt will display and meter will power off Turn dial to OFF position disco...

Страница 17: ...vironment 32 F to 122 F 0 C to 50 C at 70 RH Storage temperature 4 F to 140 F 20 C to 60 C 0 to 80 RH with battery removed Accuracy Stated accuracy 73 F 9 F 23 C 5 C 75 RH Temperature coefficient 0 1 x specified accuracy per C 0 C to 19 C 32 F to 66 F 28 C to 50 C 82 F to 122 F APO Auto Power Off Approx 30 minutes Power Single standard 9 volt battery NEDA 1604 JIS 006P IEC 6F22 Battery life 100 ho...

Страница 18: ...is device and its antenna s must not be co located or operating in conjunction with any other antenna or transmitter IMPORTANT NOTE FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20cm between the radiator your body IC Statement This device con...

Страница 19: ...tive unit at its option subject to verification of the defect This warranty does not apply to defects resulting from abuse neglect accident unauthorized repair alteration or unreasonable use of the machine Any implied warranties arising from the sale of a Fieldpiece product including but not limited to implied warranties of merchantability and fitness for a particular purpose are limited to the ab...

Страница 20: ...38 SC480 Fieldpiece Instruments Inc 2020 v12 ...

Отзывы: