SPECIFICATIONS

Display:

3½ digit liquid crystal display (LCD) with a

maximum reading of 1999.

Overrange:

"OL" mark indication.

Auto power off:

60 minutes.

Operating environment:

32 to 122

°

F (0 to 50°C) at

<70% R.H.

Storage temperature:

-4 to 140

°

F (-20 to 60°C), 0

to 80% R.H. with battery removed.

Accuracy:

Specifications good in ambient condi-

tions of 73

°

F

±

9

°

F (23°C 

±

5°C), <75% relative

humidity.

Temperature Coefficient:

0.1

×

(specified accuracy)

per 

°

F/°C. (32 to 64

°

F (0 to 18°C), 82 to 122

°

F

(28 to 50°C)).

Power:

Single standard 9-volt battery, NEDA 1604,

JIS 006P, IEC 6F22.

Battery life:

300 hours typical with alkaline.

Accessories:

One pair test leads, one pair alligator

clips, k-type thermocouple (HS33), 9V battery
(installed), and operating instructions.

Safety:

UL, CE, Cat III 600V, UL3111,

IEC/EN61010-1, C-Tick certified.

Diode test

Test current:

1.0mA

Accuracy:

±

(1.5% rdg + 3 dgts)

Open circuit volts:

3.0VDC typical

Overload protection:

500VDC or AC rms

Continuity

Audible indication:

Less than 100

Ω

Response time:

100ms

Green LED will be on continuously.

Overload protection:

500VDC or AC rms

Capacitance

Range:

200

μ

F

Resolution:

0.1

μ

F

Accuracy:

±

(3% rdg + 5 dgts)

Overload protection:

500VDC or AC rms

DC volts

Ranges:

200mV, 2000mV, 20V(HS32), 200V

Resolution:

0.1mV

Accuracy:

±

(0.5% rdg + 1 dgt)

Input impedance:

560k

Ω

on V inputs, 10M

Ω

on

mV input

Overload protection:

600VDC or AC rms,

500VDC/350VAC rms 15 sec on 200mV range

Transient protection:

6kV for 10

μ

 sec

AC volts (50Hz - 500Hz)

Ranges:

200mV, 200V, 600V

Resolution:

0.1mV

Accuracy:

±

(1.2% rdg + 3 dgts) 

±

(2.0% rdg + 5

dgts) on 600V range

Input impedance:

560k

Ω

on V input, 10M

Ω

on mV

input

Overload protection:

600V DC or AC rms

Transient protection:

6kV for 10

μ

 sec

Resistance

Ranges:

200

Ω

, 200k

Ω

Resolution:

0.1

Ω

Accuracy:

±

(1.0% rdg + 4 dgts)

Open circuit volts:

0.3VDC typical, (3.0VDC on

200

Ω

range)

Overload protection:

500VDC or AC rms

Temperature (HS33)

Range:

-30 to 200

°

F (-34 to 93°C)

Resolution:

0.1

°

F/°C

Accuracy:

±

1

°

F, 32 to 120

°

F (0 to 48°C), 

±

1% + 1.5

°

F, -4 to 200

°

F (-20 to 93°C),

±

2% + 3

°

F, -30 to -4

°

F (-34 to -20°C).

Sensor type:

K-type thermocouple

Overload protection:

60 VDC or 30 VAC rms

Available Fieldpiece access. heads

There is a Fieldpiece accessory head available for

just about any job. There are heads to measure tem-
perature, RH%, wet bulb, dew point, vacuum
(microns of mercury), manometer (inches of water
column), amps AC&DC, high voltage, CO, CO2, air
velocity, and many more.

Using & storing test leads

Because the wire insulation is silicone the leads

will stay flexible in cold weather and will not melt if
bumped by a soldering iron.

Disconnect top half of test lead and plug tip direct-

ly into meter to make voltage testing easy. Use with
included alligator clip (ASA2) as shown for even eas-
ier operation.

For convenient lead storage, wrap the leads as

shown. Pull leads around front between overhanging
tips, twist, and pull over one of the lead plugs.

Voltage

Capacitance

Resistance

Selecting Ranges

For DC voltage, set the meter to the VDC parame-

ter instead of VAC as shown above.

For all ranges choose a range just above the value

you expect. If display reads “OL” (overload), select a
higher range. If display shows less than three num-
bers, select a lower range for better resolution.

Temperature (HS33) 

Works with Fieldpiece accessory

heads!

Connect to Fieldpiece accessory heads by simply

attaching them to the top of meter 

(1)

or attach

remotely through leads 

(2)

. For most heads, move

dial to range shown 

(1)

. For the AAC clamp (ACH4),

move dial to VAC range 

(2)

.

Disconnect  test

leads  from  volt-

age  before  plug-

ging  in  thermo-

couple!

Insure the tem-

perature being
measured is stable.
Maintain good con-
tact between the
thermocouple and
what's being meas-
ured. 

CAT.III

300V
400A

CLAMP

ACH4

AC Current

Clamp

1AAC / 1mVAC

400AAC MAX

!

(1)

(2)

The velcro strip supplied is

intended to be used as shown
on the right. Tie thermocouple
like this and wrap velcro
around surface to make sure
bare wires are in close con-
tact with surface being meas-
ured. This is especially help-
full when taking pipe temps. 

The k-type thermocouple

supplied is designed with a
“wrap tab” to keep the wire
out of the way when not
needed. Just wrap the wire
around tab and pull through
the hole at the top to keep in
place as shown to the left. No
more clutter when stored.